Cruise Ship: Stad Amsterdam Cruise Line: Rederij Clipper Stad Amsterdam Inspection Date: 04/22/2011 Inspection Score: 93
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 06
Site: Potable Water-Far Point Records
Violation: There was no chart recorder for the halogen analyzer. There were no chart records or manual records of the free residual halogen for the far point. Staff stated they conduct manual comparison tests throughout the day with the analyzer, and calibrate the analyzer using these manual tests.
Recommendation: Ensure that a halogen analyzer-chart recorder is installed at a distant point in the potable water distribution system where a significant water flow exists. In cases where dual distribution loops exist, and no pipes connect the loops, ensure that an analyzer and chart recorder is installed on each loop. Ensure that the daily, manual comparison test or calibration is recorded on the chart or in a log book. Ensure that records from the halogen analyzer-chart recorder verify the free residual halogen between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) in the water distribution system for at least 16 hours in each 24-hour period since the last inspection of the vessel.
Item No.: 06
Site: Potable Water-Far Point Halogen Analyzer
Violation: The far point halogen analyzer was located in the engine room at the beginning of the distribution system.
Recommendation: Ensure that a halogen analyzer-chart recorder is installed at a distant point in the potable water distribution system where a significant water flow exists. In cases where dual distribution loops exist, and no pipes connect the loops, ensure that an analyzer and chart recorder is installed on each loop. The far point selection should be validated over numerous points throughout the distribution system under a variety of operating conditions.
Item No.: 08
Site: Potable Water-International Shore Connection
Violation: There was no reduced pressure assembly installed on the international shore connection for the fire suppression system.
Recommendation: The vessel shall provide a comprehensive cross-connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (15) International shore connection for fire/sprinkler high saline overboard discharge from evaporators, or other such cross-connection involving high pressure require the installation of a reduced pressure assembly backflow prevention device.
Item No.: 08
Site: Potable Water-Fresh Water Tank Maintenance
Violation: Documentation of the cleaning and disinfection (to include concentration and contact time) was not documented. There was no indication that flushing of the fresh water tanks was conducted prior to placing the tanks back into service.
Recommendation: Ensure that documentation of any inspection, cleaning, disinfection (including concentration and contact time of disinfectant), and flushing is maintained for 12 months and is available to the VSP for review during inspections. Ensure that the disinfected parts of the system are flushed with potable water until the free residual halogen is at or below 5.00 mg/L (ppm).
Item No.: 41
Site: Ventilation-
Violation: The condensation collection pans for the air handling units could not be visually inspected for maintenance and cleaning.
Recommendation: Ensure that air handling unit condensate drain pans and collection systems are accessible for inspection, maintenance, and cleaning.
Item No.: 08
Site: Potable Water-Bunkering Records
Violation: The manual records for the bunkering of potable water only indicated one daily reading of 2 ppm free residual halogen. Staff stated manual tests were conducted periodically during bunkering, however each concentration was not recorded.
Recommendation: Ensure that free residual halogen monitoring is performed at least hourly during the bunkering of potable water and performed at least once every 4 hours during the onboard production of potable water.
Item No.: 18
Site: Provisions-Walk-In Freezer
Violation: Packaged frozen raw meat was stored on vegetables. Raw frozen chicken was stored above raw frozen packages of fish and beef. Reorganization of the raw meats was in process during the inspection.
Recommendation: Ensure that food is protected from cross-contamination by: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food including other raw animal food such as fish for sushi or molluscan shellfish, or other raw ready-to-eat food such as vegetables, and cooked ready-to-eat food; so products do not physically touch, and so as to prevent dripping of one product into another. Ensure that food is protected from cross-contamination by: (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry during storage, preparation, holding, and display by using separate equipment for each type, or arranging each type of food in equipment so that cross-contamination of one type with another is prevented, and preparing each type of food at different times or in separate areas.
Item No.: 21
Site: Food Service General-Food Storage, Preparation and Service, and Bars
Violation: Varnished wooden shelves with difficult to clean joints and seams were used to store packages of food and beverages, such as beer kegs.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Food Service General-Food Storage, Preparation and Service, and Bars
Violation: Spilled food and food residue was in the difficult to clean areas of the wooden shelves. Food residue was also on the back bulkhead of the utensil lift.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Food Service General-Food Storage, Preparation and Service, and Bars
Violation: There were gaps in the bulkheads at the conduit and pipe penetrations. This creates difficult to clean areas and allows for the possible passage of insects.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair. Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 30
Site: Galley-Central Handwash Station
Violation: The covered waste container for the handwash station was also used in the soiled utensil drop-off area. Crew members could recontaminate their hands when they opened the covered container.
Recommendation: Install a separate waste container for the handwash station. Ensure the waste container for the handwash station is only used for paper towels and gloves.
Item No.: 20
Site: Galley-Cold Preperation
Violation: There were slotted fasteners in the food contact area of the slicer and mixer.
Recommendation: Replace the slotted fasteners with low profile, non-slotted, non-corroding, and smooth fasteners.
Item No.: 26
Site: Galley-Cold Prep
Violation: There was dried food residue on several knife blades and on the inside of a measuring cup.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 20
Site: Galley-Cold Preperation
Violation: In the reach-in cooler, there was a pool of condensate on the bottom of the interior that dripped onto the deck when the door was opened. The bottom of the food containers were in the pooled condensate.
Recommendation: Ensure that food contact equipment is maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
Item No.: 21
Site: Galley-Hot Preperation
Violation: The area to the right of the double stack combination ovens against the flat top grill unit was difficult to clean.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 37
Site: Galley-Dishwash
Violation: There was condensate on the bulkhead and the ventilation hood in the dishwash area. The condensate was dripping from the ventilation hood onto the clean area. There was no equipment or utensils exposed to the dripping condensate at the time of the inspection.
Recommendation: Ensure that ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them. Ensure that exhaust ventilation hood systems in food preparation and warewashing areas including components such as hoods, fans, guards, and ducting are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 21
Site: Provisions-Walk-In Freezer
Violation: Difficult to clean plastic crates were used for packaged food storage. These same empty crates were used to keep other food storage containers off of the deck, creating difficult to clean areas.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 29
Site: Bar-Outside Bar
Violation: There was a beer glass rinse manifold attached to the handwash sink faucet.
Recommendation: Remove the beer glass rinse manifold.
Item No.: 22
Site: Bar-Outside Bar
Violation: The undercounter dishwash machine did not have a manufacturer's data plate. This was being corrected at the time of the inspection.
Recommendation: Ensure that warewashing machines are provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
Item No.: 21
Site: Buffet-Hot Buffet
Violation: There was no side shield on the right side of the sneeze guard.
Recommendation: Install the side shield on the sneeze guard.
Item No.: 33
Site: Buffet-Hot and Cold Lines
Violation: There was no coving at the deck/counter junctures at the hot and cold lines, or at the deck/bulkhead junctures at the hot line.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 38
Site: Galley-Central Handwash Station
Violation: The rack near the handwash station waste container was used to store a potable water hose.
Recommendation: Ensure that only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 26
Site: Bar-Inside Bar
Violation: The milk container and the cabinet at the coffee machine appeared to be clean, but had a sour milk odor.
Recommendation: Identify the odor and attempt to control it.
*Inspections scores of 85 or lower are NOT satisfactory