Item No.:
*
|
|
Site:
*General Comments-
|
|
Violation:
The sanitary management and operations in all departments was highly organized and performing well on this evaluation.
|
|
Recommendation:
|
|
|
Item No.:
03
|
|
Site:
Potable Water-Bunkering Records
|
|
Violation:
A review of the manual testing log made during bunkering showed some days where the free chlorine residual was below 2 ppm on one or two tests and no adjustment was recorded on the log. The log specifically has a column beside each reading to note adjustments to the chlorine concentrations.
|
|
Recommendation:
Ensure that when the free chlorine residual falls below the minimum 2.0 ppm there is an immediate adjustment at least equal to the amount below and the record of that adjustment is made.
|
|
|
Item No.:
20
|
|
Site:
Galley-Deck 5 Coffee Station
|
|
Violation:
The bulk milk tubes were longer than one inch.
|
|
Recommendation:
Ensure that the bulk milk container dispensing tube is cut on the diagonal leaving no more than 25mm (1 inch) protruding from the chilled dispensing head.
|
|
|
Item No.:
21
|
|
Site:
Dining Room-Discovery and Aqualina
|
|
Violation:
There was damaged wood surfaces on the fronts and interiors of all the waiter stations in both restaurants. The exposed wood was raw and absorbent. The lower doors also had peeling laminate. The staff showed the inspector an example modification and stated that the remaining waiter stations would be modified.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
25
|
|
Site:
Galley-Dishwash Area
|
|
Violation:
A wet cloth was draped over the side of a sanitizing bucket.
|
|
Recommendation:
Ensure that wiping cloths used for wiping food spills are dry and used for wiping food spills from tableware and single-service articles; or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment.
|
|
|
Item No.:
27
|
|
Site:
Galley-Hot Galley
|
|
Violation:
The drip tray housings and area around the grease chutes where they entered the drip tray housings on the flat-top grills were soiled.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Bar-Pool
|
|
Violation:
Two of the refrigeration lines in the technical space below the port speed rail were soiled.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
28
|
|
Site:
Galley-Pot Wash
|
|
Violation:
A crew member was observed drying utensils with a cloth.
|
|
Recommendation:
After cleaning and sanitizing, ensure that equipment and utensils are air-dried or adequately drained before contact with food.
|
|
|
Item No.:
29
|
|
Site:
Bar-Sundeck
|
|
Violation:
The drain for the ice crusher was routed to the handwashing sink.
|
|
Recommendation:
Ensure that handwashing facilities are used for no other purpose and are accessible at all times.
|
|
|
Item No.:
33
|
|
Site:
Food Service General-Sailcloth Deckheads
|
|
Violation:
The deckhead over the deck 9 grill area aft beverage station, Sundeck bar, and Sundeck beverage station was a difficult to clean, soft sailcloth material. According to the staff, this will be changed in the March 2012 dry dock.
|
|
Recommendation:
Ensure that bulkheads and deckheads have smooth, hard finishes, and light colored surfaces.
|
|
|
Item No.:
33
|
|
Site:
Galley-Chemical Locker
|
|
Violation:
There were gaps around the bulkhead potable water line penetrations where the profile plates were loose.
|
|
Recommendation:
Tightly seal or replace the loose profile plates to close the water line penetrations in the bulkhead.
|
|
|
Item No.:
39
|
|
Site:
Galley-Butcher Shop
|
|
Violation:
There was a fly in this area.
|
|
Recommendation:
Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
|
|