Item No.: 37
Site: Galley-Warewash
Violation: The ambient temperature in the warewash room measured 87°F. The staff member working on the soiled end of the flight-type warewash machine was perspiring.
Recommendation: Ensure that all food preparation, warewashing, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
Item No.: 21
Site: Food Service General-Food Warmers
Violation: Black and gold paint was bubbling and peeling from the front, top and side surfaces of the hot holding units, which created a difficult to clean surface.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 36
Site: Galley-Toast Station Starboard Side
Violation: The artificial illumination above the counter-mounted toasters was insufficient.
Recommendation: Ensure that the light intensity is at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 33
Site: Galley-Toast Station Starboard
Violation: The deckhead, the fire sprinkler and the bulkhead had a heavy accumulation of dust and lint.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 22
Site: Galley-Potwash
Violation: Excessive steam was escaping from a missing seal along the soiled landing of the hood-type pot-wash machine.
Recommendation: Ensure that warewashing equipment is maintained in good repair and proper adjustment including: (1) Being maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; and (2) Maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
Item No.: 36
Site: Galley-Piano Bar
Violation: The florescent bulbs along the back bar counter were not shatter resistant.
Recommendation: Ensure that light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
Item No.: 36
Site: Galley-Toast Station Port Side
Violation: The artificial illumination at the counter and counter-mounted toasters was not sufficient. The light bulb was burnt-out.
Recommendation: Ensure that the light intensity is at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 16
Site: Bar-Explorations Cafe
Violation: A large carton of milk in the undercounter refrigerator had a temperature of 45°F. The ambient temperature of the refrigerator was 48°F.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
Item No.: 20
Site: Bar-Explorations Cafe
Violation: The metal plates on the right and left side of the espresso machine at the dispensing nozzles were corroded and difficult to clean.
Recommendation: Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Item No.: 36
Site: Dining Room-Officer's Mess - Beverage Station
Violation: The artificial illumination near the counter mounted juice dispensing nozzle was not sufficient.
Recommendation: Ensure that the light intensity is at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 26
Site: Dining Room-Officer's Mess - Beverage Station
Violation: The stainless steel backsplash behind and adjacent to the dispensing nozzle had an old deposit of a sticky residue.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 20
Site: Dining Room-Officer's Mess - Beverage Station
Violation: Four bundled stainless steel tubes that made up the dispensing nozzle had a gap in the center of the bundle that was not easy to clean.
Recommendation: Place food grade sealant in the center of the bundle of tubes.
Item No.: 08
Site: Food Service General-Hood Cleaning System
Violation: The backflow prevention assemblies for the hood cleaning systems in the main galley, crew galley, Pinnacle galley and hamburger galley consisted of a continuous pressure rated 9DM2 assembly. The assemblies were rated for continuous pressure, but not high-pressure that could be exerted by the hood cleaning pump. In addition, the cross-connection control list did not list the 9DM2 assemblies in the crew galley, hamburger galley, and the Pinnacle galley.
Recommendation: Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program