Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Safari Quest Cruise Line: Un-Cruise Adventures Inspection Date: 05/20/2011 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 20
Site: Galley-
Violation: There were slotted fasteners in the food splash zone above the flat grill and stove top. The fasteners were located approximately 20 inches above the grill and stove top.
Recommendation: Replace the slotted fasteners with low profile, non-slotted, non-corroding, and smooth fasteners.
Item No.: 30
Site: Galley-
Violation: The lid for the waste receptacle for the handwash station was not self-closing. Staff had to press the lid to close it, resulting in possible contamination of their hands.
Recommendation: Replace the waste receptacle with an uncovered or foot-pedal lid.
Item No.: 27
Site: Galley-
Violation: The area on top of the dishwash machine and below the counter top was heavily soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Galley-
Violation: There was a seam along the window ledge/counter top juncture.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 08
Site: Bar-
Violation: There was no backflow prevention device for the non-carbonated potable water connection for the soda dispenser hoses.
Recommendation: Install a continuous pressure backflow prevention device between the potable water connection and the soda dispenser hose.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan
Violation: The outbreak prevention and response plan did not indicate that public areas were sanitized on a continuous basis during elevated cases of gastrointestinal illness.
Recommendation: Ensure that when the cumulative proportion of cases of gastrointestinal illness among passengers or crew members is 2%, the infection control response includes cleaning and disinfecting all public areas, including handrails and restrooms, on a continuous basis until the proportion decreases to < 2%.
Item No.: 08
Site: Potable Water-Tank Maintenance Records
Violation: The fall 2010 tank maintenance records for cleaning and disinfecting of the potable water tanks could not be located.
Recommendation: Ensure that documentation of any inspection, cleaning, disinfection (including concentration and contact time of disinfectant), and flushing is maintained for 12 months and is available to the VSP for review during inspections.
Item No.: 04
Site: Potable Water-Distant Point
Violation: The free residual halogen at the distant point measured 0.12 ppm using the inspector's equipment. The halogen analyzer was malfunctioning at the time of the inspection.
Recommendation: Ensure that the halogenation device provides continuous halogenation of the potable water distribution system and maintains a free residual halogen between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) throughout the distribution system.
Item No.: 26
Site: Bar-Ice Machine
Violation: The manifold above the ice cuber was soiled.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program