Item No.:
20
|
|
Site:
Galley-Fish Preparation Room
|
|
Violation:
Five table top cutting blocks were scratched and scored, making them difficult to clean.
|
|
Recommendation:
Ensure that multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
21
|
|
Site:
Galley-
|
|
Violation:
The trolleys used to move dishes and serving trays were scratched and scored in many areas leaving rough surfaces that are difficult to clean.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Galley-Starboard Coffee Station
|
|
Violation:
The power cables of the coffee machines were too long and draped on the counter.
|
|
Recommendation:
Shorten the power cables of the coffee machines or secure them above the counter.
|
|
|
Item No.:
22
|
|
Site:
Galley-Dishwash
|
|
Violation:
During the active use of conveyor dishwash machine #2, the gauge display for the final sanitizing rinse temperature was 180°F while the temperature measured at the dish surface was 128°F. Also, the pressure gauge was not moving. Both gauges were repaired..
|
|
Recommendation:
Ensure that warewashing equipment is maintained in good repair and proper adjustment including: (1) Being maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; and (2) Maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
|
|
|
Item No.:
24
|
|
Site:
Galley-Dishwash
|
|
Violation:
During the active use of conveyor dishwash machine #2, the final sanitizing rinse temperature measured at the dish surface was 128°F. This was corrected.
|
|
Recommendation:
In a mechanical operation, ensure that the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F), or less than: (1) For a stationary rack, single temperature machine, 74°C (165°F); or (2) For all other machines, 82°C (180°F); or (3) A utensil surface temperature of 71°C (160°F) as measured by an irreversible registering temperature indicator shall be achieved. (4) The maximum temperature of 90°C (194°F), does not apply to the high pressure and temperature systems with wand-type, hand-held, spraying devices used for the in-place cleaning and sanitizing of equipment such as meat saws.
|
|
|
Item No.:
26
|
|
Site:
Galley-Meat Preparation Area
|
|
Violation:
The shaft of the out of order meat grinder was soiled with old food residue.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Galley-
|
|
Violation:
The ice bin of the starboard ice machine was soiled at the edges of the upper panel with a black material that appeared to be mold.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Galley-
|
|
Violation:
The upper technical compartments of the starboard ice machine and the ice crushing machine were heavily soiled in many areas with dust and a black material that appeared to be mold.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Galley-
|
|
Violation:
The wheels of the trolleys used to move dishes and serving trays were extremely dusty.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Galley-
|
|
Violation:
The handwash station located in front of the ice crushing machine was soiled with a black residue around the drain pipe under the wash bowl.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
29
|
|
Site:
Galley-
|
|
Violation:
There were paper cards in the waste receptacle of the handwash station located in front of the ice crushing machine.
|
|
Recommendation:
Ensure that handwashing facilities are used for no other purpose and are accessible at all times.
|
|
|
Item No.:
29
|
|
Site:
Galley-Potwash
|
|
Violation:
The handwash in this area was partially blocked by a trash bin. The trash bin was moved. This area was in active use at the time of the inspection.
|
|
Recommendation:
Ensure that handwashing facilities are used for no other purpose and are accessible at all times.
|
|
|
Item No.:
33
|
|
Site:
Galley-
|
|
Violation:
The bulkhead behind the starboard ice machine was extremely dusty.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Crew Mess
|
|
Violation:
The deck under reach-in refrigerator #2 was heavily soiled. In addition, the bulkhead under the adjacent counter was soiled.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Dry Storage
|
|
Violation:
The bulkhead behind the storage shelves had exposed insulation, making it difficult to clean.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
38
|
|
Site:
Food Service General-Out of Order Equipment
|
|
Violation:
A number of different equipment were posted as out of order, e.g. meat grinder in the meat preparation room, undercounter refrigerators all over the main galley, and water boiler in the main galley. These pieces of equipment had been out of order from 2 months up to several years.
|
|
Recommendation:
Repair, replace, or remove the out of order equipment.
|
|