Cruise Ship: Asuka II Cruise Line: NYK Cruises Co., LTD Inspection Date: 07/07/2009 Inspection Score: 99
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 33
Site: Provisions-Pickles and Dairy Room
Violation: There were three holes in the bulkhead to the left of the exit door in these provision rooms.
Recommendation: Close the holes.
Item No.: 33
Site: Preparation Room-
Violation: There was a hole at the bottom of the profile strip to the left of the upright freezers.
Recommendation: Close the hole.
Item No.: 33
Site: Preparation Room-
Violation: There was a gap between the back of the upright freezers and the bulkhead to the right of the freezers. This gap was small and made cleaning the area behind the freezers difficult.
Recommendation: Profile the gap.
Item No.: 33
Site: Preparation Room-
Violation: There were two unsealed pipe penetrations in the bulkhead to the right of the floor mounted mixer.
Recommendation: Seal the penetrations.
Item No.: 27
Site: Galley-Hot Galley
Violation: The previously cleaned flattop grill drip pan housing was heavily soiled with old grease.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Galley-Hot Galley
Violation: There were peeling panel labels on the tilting pans.
Recommendation: Ensure that nonfood-contact surfaces of equipment and utensils are designed and constructed to be durable and to retain their characteristic qualities under normal use conditions.
Item No.: 33
Site: Galley-
Violation: The deck under equipment near the bulkhead had broken and missing tiles.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair. Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 37
Site: Galley-Hot Galley
Violation: Condensate had collected on the deckhead above the soup kettles.
Recommendation: Ensure that ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: 20
Site: Galley-Pot Wash
Violation: Three white cutting boards in clean storage were rough and scored.
Recommendation: Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Item No.: 33
Site: Buffet-
Violation: The bulkhead inside the technical space below the hot hold was rough and cracked.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 22
Site: Galley-Starboard Dishwash
Violation: The glasswash machine temperature measuring device for the wash tank was not working.
Recommendation: Ensure that warewashing equipment is maintained in good repair and proper adjustment including: (1) Being maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; and (2) Maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
Item No.: 33
Site: Food Service General-Food Preparation Areas
Violation: There were several laminated signs posted on the bulkhead throughout the food preparation areas that were peeling away from the bulkhead or soaked with water.
Recommendation: Ensure that surfaces subject to routine splashes, spillage, or other soiling during normal use have easily cleanable features.
Item No.: 16
Site: Galley-Cold Galley
Violation: A pan of cut tomatoes was measured at 46° F at 0955 in window 1 refrigeration unit. Per staff, the tomatoes were placed in the unit at 0730. The tomatoes were taken to the blast chiller immediately. There was no other potentially hazardous food in the unit. The ambient air temperature of the unit was below 41° F.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
Item No.: 16
Site: Galley-Cold Galley
Violation: Three trays of cut melons were measured at 50° F to 52° F. in the portable refrigeration unit. Per staff, the melons had been place in the unit overnight. The melons were immediately discarded. There was no other potentially hazardous food in the unit. The ambient air temperature of the unit was 51° F.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
Item No.: 27
Site: Galley-Hot Galley
Violation: The previously cleaned flattop grill grease drip tube was soiled with grease.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 08
Site: Galley-Hot Galley
Violation: The non-continuous pressure backflow prevention device installed on the potable water line for the water bath was located before the shut-off valve.
Recommendation: Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
Item No.: 08
Site: Galley-Bakery
Violation: The potable water line fuacet supplying the ice cream dipper was not a sufficient distance above the flood rim level of the well to provide an air gap. A backflow prevention device was not installed.
Recommendation: Ensure that backflow preventers are installed when air gaps are impractical or when water under pressure is required.
Item No.: 22
Site: Galley-Port and Starboard Dishwash
Violation: The data plate on the glasswash machine in these areas was hard to read.
Recommendation: Ensure that warewashing machines are provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
Item No.: 22
Site: Galley-Port Dishwash
Violation: There was a soapy residue left on the thermometer after a complete cycle through the glasswash machine.
Recommendation: Ensure that warewashing equipment is maintained in good repair and proper adjustment including: (1) Being maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; and (2) Maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
Item No.: 33
Site: Bar-Sushi Bar
Violation: There was a gap to the right of the under side of the preparation counter next to the bulkhead.
Recommendation: Profile the gap.
Item No.: 08
Site: Potable Water-Cross Connection Control Program
Violation: The air gaps were not listed on the cross connection control program.
Recommendation: Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing. Ensure that air-gaps are included in the cross connection control program.
Item No.: 08
Site: Potable Water-Shiseido Salon
Violation: The non-continuous pressure backflow prevention devices for the three hairwash sinks were installed before the shut-off valve.
Recommendation: Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer. Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
Item No.: 40
Site: Integrated Pest Management-
Violation: The integrated pest management plan was last reviewed and revised in November 2005.
Recommendation: Ensure that the vessel's Integrated Pest Management Plan is evaluated for effectiveness every 2 years or whenever there is a significant change in the vessel's structure such as a renovation or operation. Ensure that reviews are documented and changes noted in the vessel's Integrated Pest Management Plan. Ensure that the vessel's Integrated Pest Management Plan is evaluated for effectiveness every 2 years or whenever there is a significant change in the vessel's structure such as a renovation or operation.