Cruise Ship: Seven Seas Voyager Cruise Line: Regent Seven Seas Inspection Date: 05/15/2010 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 10
Site: Recreational Water Facilities-Passenger
Violation: The depth markers were not visible from the deck.
Recommendation: Ensure that the depth of each pool is prominently displayed so that it can be seen from the deck and in the pool. Ensure that depth markers are labeled in feet or meters, or both,. Additionally, ensure that depth markers are installed for every 1 m (3 feet) in change of depth.
Item No.: 08
Site: Potable Water-
Violation: The air-gap at the fill point for the swimming pool compensation tank was not two times the diameter of the supply line.
Recommendation: Ensure that air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 3 cm (1 inch).
Item No.: 08
Site: Potable Water-
Violation: There were threaded hose connections at the sample taps for the potable water tanks. These connections were not on the cross-connection control list. There was a threaded hose connection at the sample tap for the bunker chlorine station. This connection was not on the cross-connection control list.
Recommendation: Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing.
Item No.: 08
Site: Potable Water-
Violation: The sample tap for potable water tank 8FW4S did not point down.
Recommendation: Ensure that potable water tanks have sample valves which are turned down.
Item No.: 08
Site: Potable Water-
Violation: The hose connection at the distribution system chlorine dosing station was not on the cross-connection control list.
Recommendation: Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing.
Item No.: 08
Site: Potable Water-
Violation: The detergent dispenser connection in the main laundry was not on the cross-connection control list. The potable water line supplying the detergent dispenser was not painted or striped blue.
Recommendation: Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing. Ensure that potable water piping and fittings are painted or stripped auxiliary blue, or in accordance with ISO 14726, at 5 m (15 feet) intervals on each side of partitions, decks, and bulkheads in all spaces, except where the decor would be marred by such markings.
Item No.: 08
Site: Potable Water-Main Laundry
Violation: The pvc lines supplying some of the laundry machines were blue. These were not potable water lines.
Recommendation: Add a secondary color to these lines or paint them a color other than blue.
Item No.: 06
Site: Potable Water-
Violation: There were free halogen tests during bunkering for St. Kitts on December 23 but no E. coli test. There was an E. coli test for shore-side water in St. Maarten on December 24 but no free halogen bunkering tests. The bridge log book did not show water loading for St. Maarten. According to the Staff Captain, there was probably a mix up with the record and the E. coli test that was conducted was for St. Kitts on December 23rd.
Recommendation: Where available, ensure that the vessel has a copy of the most recent microbiologic report from each port before bunkering potable water to verify that the water meets potable standards. Ensure that these records are maintained on the vessel for 12 months and available to the VSP for review during inspections.
Item No.: 08
Site: Potable Water-
Violation: The potable water hoses were not capped or coupled together .
Recommendation: Ensure that potable water hoses are stowed rolled tight with the ends capped, on reels, or racks or with ends coupled together in potable water hose lockers.
Item No.: 11
Site: Medical-
Violation: An asymptomatic cabin mate of a crew member with gastrointestinal illness did not have a 48 hour interview during the April 15-May 12 cruise.
Recommendation: Ensure that medical staff conduct daily verbal interviews with asymptomatic crew until 48 hours after onset of the ill crew members symptoms.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan
Violation: There was no disinfection frequency for the public toilet room, gym equipment, gangways or tenders when the cumulative proportion of gastrointestinal illness cases among passengers or crew reaches 2%.
Recommendation: Ensure that when the cumulative proportion of cases of gastrointestinal illness among passengers or crew members is 2%, the infection control response includes cleaning and disinfecting all public areas, including handrails and restrooms, on a continuous basis until the proportion decreases to < 2%. Ensure that each vessel has a written Outbreak Prevention and Response Plan (OPRP) which details the standard procedures and policies to specifically address gastrointestinal illness onboard. The plan shall include the duties and responsibilities of each department and their staff to include steps in outbreak management and control as well as the trigger for each step.
Item No.: 21
Site: Pantry-Casino
Violation: A cardboard box was re-used to store bottled water.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 33
Site: Bar-Casino
Violation: There were openings around the deck penetrations pipes used for electrical lines.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 21
Site: Food Service General-Flat and Grooved Grills
Violation: There were void spaces around the grease chutes where they penetrated under the grills.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 19
Site: Buffet-La Veranda
Violation: The bowls of condiments were not under the sneeze shields. This was corrected.
Recommendation: Ensure that food on display is protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
Item No.: 33
Site: Buffet-La Veranda
Violation: One of the pipe penetrations in the deck of technical space 001998 was not completely sealed.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 21
Site: Buffet-La Veranda
Violation: There was excessive, loose and peeling sealant at the floor/bulkhead junctures of undercounter refrigeration unit #47 technical space.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Buffet-La Veranda
Violation: The refrigerant lines in the technical space for undercounter refrigeration unit #48 were soiled with mold.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Buffet-La Veranda
Violation: The technical spaces for waiter stations #53 and #54 were soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Buffet-La Veranda
Violation: A few of the waiter stations side walls were not coved at the deck bulkhead junctures.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 33
Site: Galley-La Veranda
Violation: There was recessed deck tile grouting throughout the galley.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 16
Site: Food Service General-Time Control Plans
Violation: The time control plans were not specific to the flow of food in each area. For example, the plans stated that hot holding trolleys were used for time control, however there were no hot holding trolleys on the vessel. In the buffet galley, the combination oven that was used for hot holding under time control and was not listed in the plan.
Recommendation: If time only, rather than time in conjunction with temperature, is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure that (1) The food is marked or otherwise identified to indicate the time that is 4 hours past the point in time when the food is removed from temperature control; (2) The food is cooked and served, served if ready-to-eat, or discarded, within 4 hours from the time when the food is removed from temperature control; and (3) The food in unmarked containers or packages or marked to exceed a 4 hour limit is discarded. Ensure that written procedures to ensure compliance with these guidelines is maintained on the vessel and made available to the VSP, upon request.
Item No.: 33
Site: Galley-La Veranda
Violation: There were unsealed utility line penetrations in the deck of refrigeration unit #63 technical space.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Galley-La Veranda
Violation: The deck below blast chiller #60 was soiled at the bulkhead/deck juncture.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Galley-Coffee Station
Violation: The espresso machine utility line conduit was separated from the bulkhead.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 26
Site: Galley-Ice Machines #273 and #274
Violation: The exterior surfaces of the cubers were soiled with mold. The units were immediately cleaned.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 22
Site: Galley-Dishwash
Violation: The manufacturer's recommended pressure range for the final rinse was not listed on the data plate.
Recommendation: Ensure that warewashing machines are provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
Item No.: 33
Site: Other-Pool Grill
Violation: There was a sail cloth type material above the cold counter and wait stations.
Recommendation: Ensure that bulkheads and deckheads have smooth, hard finishes, and light colored surfaces.
Item No.: 21
Site: Other-Pool Grill Pantry
Violation: Utility lines were draped on the floor of upright refrigeration unit #42 technical space. This space was soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris. Raise the utility lines from the floor of the technical compartment to make cleaning easier.
Item No.: 33
Site: Galley-Prime 7
Violation: The bulkhead was soiled at the deck bulkhead juncture below a few pieces of equipment.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Galley-Prime 7
Violation: There was no coving along the deck/equipment juncture at the waiter station.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 33
Site: Galley-Dishwas Area
Violation: The deck below the chemical locker was heavily soiled.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Galley-Pastry
Violation: The deck under the cleaning locker was soiled at the bulkhead juncture.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 20
Site: Galley-Pastry
Violation: The dough sheeter belt was frayed at the seam and the edges.
Recommendation: Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Item No.: 33
Site: Buffet-Coffee Corner
Violation: There was no coving at the deck/counter juncture under the coffee machine.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).