|
|
|
Item No.:
11
|
|
Site:
Medical-Asymptomatic Crew
|
|
Violation:
Although there was good documentation made for asymptomatic cabin mates for crew gastrointestinal illness cases, there was no documentation of their immediate contacts to ensure they were also identified, interviewed and given handwashing and hygiene fact sheets.
|
|
Recommendation:
Ensure that medical staff conduct verbal interviews with asymptomatic cabin mates or immediate contacts to confirm their condition, advise them of the hygiene and handwashing facts, and instruct them to report immediately to medical if they develop illness symptoms. Ensure that medical staff conduct daily verbal interviews with asymptomatic crew until 48 hours after onset of the ill crew members symptoms.
|
|
|
Item No.:
02
|
|
Site:
Medical-Documentation of Crew
|
|
Violation:
The crew arriving to the ship were not given a written set of questions on whether or not they experienced any of the standard gastrointestinal illness symptoms up to the three days prior to boarding the ship. Staff stated this was done verbally.
|
|
Recommendation:
Ensure that crew complete a written set of questions regarding any gastrointestinal illness symptoms experienced up to 72 hours prior to boarding the ship. Retain all forms where crew report symptoms for review during inspection. Ensure that reportable cases of gastrointestinal illness include crew members with a symptom onset time of up to 3 days before boarding the vessel. Maintain documentaion of the 3 day assessment, for each crew member WITH SYMPTOMS, on the vessel and make available for review during inspections.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Public Area Disinfection
|
|
Violation:
The written gastrointestinal illness outbreak prevention plan was not clear in that it specified in section 4.2.2 that under level 2 cleaning/disinfection as part of the anti-viral rounds the cleaning should be done continuously every two hours. This was specifically based on a gastrointestinal illness case count between 1and 4 crew or passengers and should be done until the case percentage falls below 2%. The level 3 anti-viral rounds were triggered when more than 4 GI cases reported, but the frequency for disinfecting surfaces in public areas was given as hourly. The plan should be revised to reflect the need to use the cleaner/disinfectant on the various public area surfaces continuously when passengers or crew are using those spaces, both inside the ship and on open decks, and until the case percentage falls below 2. This finding was also noted in the previous VSP inspection.
|
|
Recommendation:
Ensure that when the cumulative proportion of cases of gastrointestinal illness among passengers or crew members is 2%, the infection control response includes cleaning and disinfecting all public areas, including handrails and restrooms, on a continuous basis until the proportion decreases to < 2%. Ensure that when the cumulative proportion of cases of gastrointestinal illness among passengers or crew members is 2%, the infection control response includes cleaning and disinfecting all public areas, including handrails and restrooms, on a continuous basis until the proportion decreases to < 2%.
|
|
|
Item No.:
16
|
|
Site:
Galley-Galley
|
|
Violation:
The 6 door upright reach-in refrigerator had been recently loaded with new provisions, but the butter blocks and cheese and deli meat trays inside had a food temperature of 43 °F
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
|
|
|
Item No.:
20
|
|
Site:
Galley-Galley
|
|
Violation:
The previously cleaned colored cutting boards in the undercounter clean storage cabinet were noticeably scored along both cutting side surfaces.
|
|
Recommendation:
Ensure that surfaces such as cutting blocks and boards that are subject to scratching and scoring are resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
|
|
|
Item No.:
22
|
|
Site:
Galley-Galley
|
|
Violation:
There was only a two compartment sink installed in the galley for manual warewashing. This violation was noted in the April VSP inspection. Additionally, there was no food preparation sink separate from the two compartment sink in the galley, so it was also used for food preparation purposes.
|
|
Recommendation:
Ensure that a sink with at least 3 compartments is provided for manually washing, rinsing, and sanitizing equipment and utensils.
|
|
|
Item No.:
21
|
|
Site:
Galley-Galley
|
|
Violation:
There were gaps, seams, openings, and other difficult to clean features present on the non-food contact surfaces of equipment. There were gaps and open pipe penetrations in undercounter cabinets, such as below the 2 compartment sinks, and the gap present in the range tops grease pan housing was deep and too narrow for easy cleaning. This is a repeat finding from the April VSP inspection.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Galley-Galley
|
|
Violation:
The interior of the two range tops grease pan housing were soiled with old accumulated grease residue. Staff had improved this considerably from the previous report, but there were still areas inside which were too difficult to properly reach and clean. This was noted in the April VSP inspection report.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
33
|
|
Site:
Galley-Galley
|
|
Violation:
The deckheads were difficult to clean due to loose or damaged profile strips, gaps along sections such as forward/starboard over the electrical junction boxes, aft/staboard over the reach-in refrigerator, and at the forward end of the exhaust hood where heavy soil was present in the gap formed betwen the hood and the deckhead cabinet adjacent. These features were noted in the April VSP inspection.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair. Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
22
|
|
Site:
Galley-Galley
|
|
Violation:
A sponge was used in the quaternary ammonia sanitizing solution bucket.
|
|
Recommendation:
Ensure that sponges are not used in contact with cleaned and sanitized or in-use food-contact surfaces.
|
|
|
Item No.:
28
|
|
Site:
Galley-Galley
|
|
Violation:
The drains from the warewashing sinks were directly connected to the garbage grinder and then to the wastewater tank in the decks below without an air-break.
|
|
Recommendation:
Ensure that all drain lines from warewashing sinks or machines drain through an air-gap or air-break to a drain or scupper.
|
|
|
Item No.:
33
|
|
Site:
Galley-Galley - Walk-in Freezer
|
|
Violation:
The upper level storage for the walk-in freezer had a dishware rack on the deck as a stand for various fillets of frozen fish.
|
|
Recommendation:
Store food containers on deck stands at least six inches above the deck surface to protect the foods and to allow sufficient access for cleaning the deck below.
|
|
|
Item No.:
21
|
|
Site:
Provisions-Aft Upper Deck Fruit/Vegetable Stores
|
|
Violation:
The open deck fresh fruit and vegetable locker on port and starboard sides were set on wood planks which were only elevated 1 inch above the deck.
|
|
Recommendation:
Ensure that deck-mounted equipment that is not easily movable is sealed to the deck or elevated on legs that provide at least a 150 mm (6-inch) clearance between the deck and the equipment.
|
|
|
Item No.:
05
|
|
Site:
Potable Water-Potable Water - Far Point Analyzer
|
|
Violation:
The analyzer free halogen display was 1.32 ppm while the manual test from the inspector's kit measured 1.78 ppm.
|
|
Recommendation:
Ensure that the free residual halogen measured by the halogen analyzer is ±0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
|
|