|
|
|
Item No.:
*
|
|
Site:
Housekeeping-Housekeeping and Galley Areas
|
|
Violation:
It was unclear exactly how the Hepburn Biocare sanitizing and disinfection chemicals were being used in relation to the description of those products and their hazard description. They were in use in public spaces, cabins, and food areas for various surface sanitizing or disinfection. Additionally the product literature specified that staff should be trained on the product prior to use and to date no ship staff have been trained.
|
|
Recommendation:
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Potable Water Tanks - Coating
|
|
Violation:
All the potable water tanks were re-coated in May 2010. The written record on the coating did not include information from the ship's staff who did the work, specifying that the coating was applied, dried and cured according to the manufacturer's specification. The ship did not have the written information verifying the product (Sigma Guard CSF 585) was approved for coating potable water tanks. The information was located thru a web search and printed for the permanent records.
|
|
Recommendation:
Ensure that interior coatings on potable water tanks are approved for potable water contact, and all manufacturer's recommendations for application, drying, or curing are followed. Ensure written documentaion for the coating used and recommendations followed are avaialble for review during inspections.
|
|
|
Item No.:
10
|
|
Site:
DO NOT USE (whirlpool/spa)-Port and Starboard Whirlpool Spa - Drains
|
|
Violation:
The single gravity drain covers on the port and starboard whirlpool spa tubs were not designed for anti-entrapment/entanglement.
|
|
Recommendation:
Ensure that anti-entrapment drain covers or other drains that prevent entrapment hazards as specified in U.S. Consumer Product Safety Publication 363-009801 (dual drains/channel drains) are provided on swimming pools and whirlpool spas. Ensure that drain covers have either the plumbing/engineering approving organization stamp and flow rate affixed to the cover, or that a letter is maintained aboard the vessel certifying that the cover meets the safety requirements outlined in AMSE/ANSI A112.19.8M or an equivalent standard.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross-connection Control Plan
|
|
Violation:
The 3 crew and main galley dishwash pulper potable water supply pipes were protected with N9 model Watts backflow preventers, but listed in the ship's cross-connection control plan as 8 series preventers. Additionally, the housekeeping chemical dispensing locker located on deck 4 had backflow preventers installed on each dispenser but there was no listing in the plan for them.
|
|
Recommendation:
Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing.
|
|
|
Item No.:
41
|
|
Site:
Ventilation-All Air-Conditioning Fan Rooms - Fan Units
|
|
Violation:
There was no method for inspection of the condensate collection pans for any of the AC fan units throughout the ship. Sight windows were cut in the side of the fan coils for most AC fan units, but they were not in the correct postion to view inside the condensate collection pans for each unit.
|
|
Recommendation:
Ensure that air handling unit condensate drain pans and collection systems are accessible for inspection, maintenance, and cleaning. Installation of sight windows or other effective methods for full inspection and cleaning of condensate collection pans shall be utilized when original equipment access makes evaluation during operational inspections impractical.
|
|
|
Item No.:
36
|
|
Site:
Bar-Panorama Bar
|
|
Violation:
Verify that the deckhead mounted lights over the front bar are shatter-resistant, as none were shielded.
|
|
Recommendation:
Ensure that light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
|
|
|
Item No.:
21
|
|
Site:
Pantry-Panorama Bar - Pantry
|
|
Violation:
The braided steel flexible water line connected to the expresso/cappuccino machine was draped on the countertop, making cleaning difficult.
|
|
Recommendation:
Elevate the water line so the counter below is easy to access and clean.
|
|
|
Item No.:
40
|
|
Site:
Pantry-Pool Bar - Pantry
|
|
Violation:
The door from the front bar to the pantry behind was pinned open, allowing easy insect access. The pool bar is an outdoor bar. No pests were found in the pantry, but there were exposed clean dishware in storage at the time, as the bar was in service.
|
|
Recommendation:
Ensure that entry points where pests may enter the food areas are protected.
|
|
|
Item No.:
15
|
|
Site:
Bar-Pool Bar
|
|
Violation:
A bottle of sour mix and a bottle of triple sec had particles floating inside at the pool bar. Both were emptied during the inspection.
|
|
Recommendation:
Ensure that food is safe and unadulterated.
|
|
|
Item No.:
21
|
|
Site:
Buffet-Terrace Cafe buffet counter
|
|
Violation:
Wicker and wood baskets used for bread service were not constructed to be easily cleanable. Under paper liner, bread crumbs and food-stained wood were observed.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
20
|
|
Site:
Buffet-Terrace Cafe buffet
|
|
Violation:
Alto-Sham oven shelves were covered with aluminum foil. This inhibits heat transfer within the unit.
|
|
Recommendation:
Ensure that food-contact surfaces of food equipment complies with American National Standards Institute (ANSI) or other internationally accredited food-equipment sanitation standards for materials, design, and construction.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Poultry Freezer
|
|
Violation:
Ice build-up was noted on numerous light fixtures and had dripped onto the deck.
|
|
Recommendation:
Repair the condition causing the ice entering the light fixtures.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Meat Freezer
|
|
Violation:
Profile strip between deckhead and bulkhead had separated making it difficult to clean.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
|
|
|
Item No.:
21
|
|
Site:
Buffet-Beverage Station
|
|
Violation:
Counter equipment cords were draped under the units making it difficult to clean. Food soil was noted on the counter and on the cords.
|
|
Recommendation:
Elevate the power cords to counter equipment so the counter is easy to access and clean.
|
|
|
Item No.:
21
|
|
Site:
Buffet-Soiled Dish Return
|
|
Violation:
Trash cans were in disrepair and difficult to clean. Heavy food soil was noted on the outside of one can.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment and utensils are designed and constructed to be durable and to retain their characteristic qualities under normal use conditions.
|
|
|
Item No.:
21
|
|
Site:
Buffet-Officer Mess Beverage Station
|
|
Violation:
Counter equipment cords were draped under the units making it difficult to clean.
|
|
Recommendation:
Elevate the power cables to countertop equipment so the counter below is easily accessible for cleaning.
|
|
|
Item No.:
08
|
|
Site:
Buffet-Officer Mess Beverage Station
|
|
Violation:
The Culligan water dispenser backflow preventer was leaking indicating possible failure. This was corrected during the inspection.
|
|
Recommendation:
Ensure that backflow preventers are maintained in good repair.
|
|
|
Item No.:
20
|
|
Site:
Galley-Dishwash Area
|
|
Violation:
A wooden cutting board was found. It was in poor repair with a rough, difficult to clean surface. The cutting board was discarded.
|
|
Recommendation:
Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
|
|
|
Item No.:
33
|
|
Site:
Room Service-
|
|
Violation:
Gaps were noted between the bulkhead and equipment storage cabinet and between the bulkhead and cleaning cabinet. Gaps are difficult to clean and are potentially insect harborage areas.
|
|
Recommendation:
Profile the gaps between the bulkhead and equipment storage and cleaning cabinets.
|
|
|
Item No.:
33
|
|
Site:
Galley-Pastry
|
|
Violation:
Food debris was noted on the deck behind the large mixer.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Galley-Pastry
|
|
Violation:
A rubber grommet was missing on the power cord for the ice cream machine at the bulkhead penetration. This creates potential insect portal to galley.
|
|
Recommendation:
Close the void at the conduit where the power cable passes thru the bulkhead penetration.
|
|
|
Item No.:
34
|
|
Site:
Galley-Hot galley
|
|
Violation:
Water fountain did not have a valve for activating water flow.
|
|
Recommendation:
Ensure that a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
37
|
|
Site:
Galley-Hot line
|
|
Violation:
Condensate from preheating bain maries was noted on the inside of the hood and on counter tops above food storage areas. This poses a potential food contamination hazard.
|
|
Recommendation:
Cover bain maries when heating to prevent steam from condensing on surfaces above and dripping back into food pans.
|
|
|
Item No.:
21
|
|
Site:
Galley-Hot galley
|
|
Violation:
Tilting skillet handle was attached with a corroded washer making it difficult to clean.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
33
|
|
Site:
Galley-Hot galley
|
|
Violation:
On the left side of the tilting skillet, water was collecting on deck near the bulkhead. Mold and old food debris was observed in this area.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
21
|
|
Site:
Galley-Hot galley
|
|
Violation:
Portable induction cart had wooden panels that were in poor repair and difficult to clean. This cart also had numerous cords draped under the equipment making the area difficult to clean. The gaskets inside the door were u-shaped, which allowed food debris to collect in the gaskets.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Buffet-Beverage Station
|
|
Violation:
Counter equipment cords were draped under the units making it difficult to clean. Food soil was noted on the counter and on the cords.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|