Cruise Ship: Arcadia Cruise Line: P&O Cruises Inspection Date: 11/14/2010 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 19
Site: Buffet-Deck 9 - Belvedere Food Court - Bread Station
Violation: There were two baskets of bread out for service that did not have serving utensils.
Recommendation: Ensure that consumer self-service operations, such as salad bars and buffets, for unpackaged ready-to-eat foods are provided with suitable utensils or effective dispensing methods that protect the food from contamination; and are monitored by food employees trained in safe operating procedures.
Item No.: 20
Site: Buffet-Deck 9 - Belvedere - Beverage Stations
Violation: The back splashes of the combination water/ice dispensers had corrosion, especially behind the ice chute and water line. In addition, there were slotted fasteners holding the water supply line in the splash zone, making cleaning difficult.
Recommendation: Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition. Ensure that food contact surfaces of equipment and utensils are designed and constructed to be durable and to retain their characteristic qualities under normal use conditions. Replace the slotted fasteners with low-profile, non-slotted, non-corroding fasteners.
Item No.: 21
Site: Buffet-Deck 9 - Belvedere - Beverage Stations
Violation: The combination water/ice machines had corrosion along the seams where the stainless steel sides were fastened to the bottom galvanized metal plate, making cleaning difficult.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 27
Site: Buffet-Deck 9 - Belvedere - Starboard Hot Counter
Violation: The leading edge of the deep fat fryer and the seams below the front edge had deposits of grease and food residue.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Buffet-Deck 9 - Belvedere - Starboard Hot Counter
Violation: The front edge of the carving station, with the attached heat lamps, was soiled with grease and food residue.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Buffet-Deck 9 - Belvedere - Staff Service Areas
Violation: In several locations, especially along the worker side of the buffet where the juncture of the poured deck material joined the stainless steel coving, there were several cracks and gaps. In a few locations on the worker side of the buffet, there was some pitting in the deck material that was not easily cleanable.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair. Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Buffet-Deck 9 - Belvedere - Ventilation Diffusers
Violation: The ventilation diffusers located along the service side of the buffet lines had peeling paint. Many diffusers were located immediately above equipment and food displays.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 21
Site: Buffet-Deck 9 - Belvedere - Desert Station
Violation: There was a void space to the right of the scupper, immediately below the refrigerated desert display unit, making cleaning difficult.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Buffet-Deck 9 - Belvedere - Countertops
Violation: There were fractures and chipped pieces along the black countertops, which made cleaning difficult. In some locations where the countertop junctures met the bulkhead, there was loose and missing sealant.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Ensure that nonfood-contact surfaces of equipment and utensils are designed and constructed to be durable and to retain their characteristic qualities under normal use conditions.
Item No.: 21
Site: Buffet-Deck 3 and Deck 4 - Equipment seams
Violation: Several pieces of equipment in the main galley on Deck 3 and 4 had seams, openings and void spaces that made cleaning difficult. Equipment included counters, sinks, cabinets, undercounter refrigerators and junctures where equipment was attached to the bulkhead, the counters and other pieces of adjoining equipment.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Dining Room-Deck 2 - Meridian Dome - Waiter Station
Violation: In some locations of the central "dome" waiter station, where there were clean/soiled landings and dry food storage, soft sealant was used as coving material. The remainder of the deck material in this location was not coved. This item was noted on the previous inspection.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 20
Site: Preparation Room-Deck B
Violation: The potato peelers had slotted fasteners in the food contact surfaces of the machines.
Recommendation: Replace the slotted fasteners with low-profile, non-slotted, non-corroding fasteners.
Item No.: 20
Site: Preparation Room-Deck A - Lido Preparation
Violation: The salad washer had slotted fasteners inside the food contact surfaces of the machine.
Recommendation: Replace the slotted fasteners with low-profile, non-slotted, non-corroding fasteners.
Item No.: 08
Site: Preparation Room-Deck A - Lido Preparation
Violation: The backflow prevention device for the salad preparation machine was corroded and weeping.
Recommendation: Ensure that backflow preventers are maintained in good repair.
Item No.: 21
Site: Galley-Deck A - Warewashing
Violation: The water supply line to the "Grime Reaper" was braided and was lying on the deck. The line was not easily cleanable.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 33
Site: Bar-Deck 2 - Rising Sun Bar
Violation: There were large gaps around the water supply lines coming from the deckhead to the water carbonator for the soda machine.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 33
Site: Bar-Deck 9 - Aquious Bar
Violation: The decorative deckhead above the worker side of the bar was constructed of sail cloth and ropes.
Recommendation: Ensure that bulkheads and deckheads have smooth, hard finishes, and light colored surfaces. Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Provisions-Dry Storage 16 and 19
Violation: The bottom of the bulkhead panels near the siding doors were bent, creating void spaces and making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan (OPRP)
Violation: The electronic outbreak prevention and response plan was very difficult to read clearly, as the various sections of the plan were updated monthly and the version remaining had all the strikethrough sections still in place and colored, so it required the reader to sort thru each section for what was not with strikethrough marks to understand what in fact was the remaining procedure to follow. In the public room/alleyway section the initial statement of procedures calls for continuous sanitizing of hand contact surfaces, but later in that same section the individual surface types are described and frequent sanitizing of these hand contact surfaces are specified. This section (3.1) refers to the procedures during the highest gastrointestinal (GI) illness response level (red code), which includes reportable GI illness cases of 2% or higher. In the red code section for disinfection in the casino nearly all the procedures have strikethrough marking in red, including the statement that the hand contact surfaces throughout this areas should be disinfected continuously. This frequency statement was missing during the previous VSP inspection (February 2010). In that report the crew internet procedure listed no disinfection frequency, but in the current OPRP it specifies continuous. The crew gym was and still is specified in the OPRP to be disinfected as frequently as possible for as long as the gym remains in service, rather than continuously.
Recommendation: Ensure that when the cumulative proportion of cases of gastrointestinal illness among passengers or crew members is 2%, the infection control response includes cleaning and disinfecting all public areas, including handrails and restrooms, on a continuous basis until the proportion decreases to < 2%. Ensure the plan addresses all hand contact areas and frequency of disinfection is clearly specified as continuous. Highly recommend a review of the OPRP and removal of strikethrough sections so staff can easily follow only what is required in each section.
Item No.: 26
Site: Pantry-Pantries 6.4.01 and 4.1.04
Violation: The in-use ice machines had accumulations of a metal dust (powder) in the water bath interior of the upper ice maker section of both machines inspected.
Recommendation: Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 11
Site: Medical-Gastrointestinal Illness Records
Violation: The monitoring and follow-up of cabin mates of ill crew were recorded well and clearly for the initial interview, 24, and 48 hour updates, but there was nothing documented to indicate whether the ill crew member did or did not have an immediate contact. Staff stated this was done verbally and if the answer was no there was no record made to indicate there was no other contact.
Recommendation: Record results of the initial ill crew members interview regarding cabin mates and immediate contacts, even when the answer is no.
Item No.: 08
Site: Potable Water-Potable Water - Distribution - Passenger Launderettes
Violation: There was no blue striping to indicate that the potable water supply pipes for the various passenger launderettes were from the potable water system.
Recommendation: Ensure that potable water piping and fittings are painted or stripped auxiliary blue, or in accordance with ISO 14726, at 5 m (15 feet) intervals on each side of partitions, decks, and bulkheads in all spaces, except where the decor would be marred by such markings.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program - Listing
Violation: The backflow preventer on the hose connection in the starboard/forward section of the garbage room and the bedpan washer in the medical center were not in the cross-connection control program listing of backflow prevention devices. This was noted previously in the February 2010 VSP inspection report. Additionally, the chemical stations located on deck 1 forward, decks 5, 6, and 8 had backflow preventers installed but were not listed.
Recommendation: Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing.
Item No.: 08
Site: Potable Water-Cross-Connection Control
Violation: There were no backflow prevention devices installed on the potable water supply lines to the deck 4 forward passenger launderette clothes washers. There were no backflow preventers installed on 3 potable water lines connecting to the hot or cold water line connections to the clothes washers in the deck 4 midship passenger launderette. The sink in the chemical station on deck A had a threaded faucet and there was no backflow preventer attached there or on the potable hot water supply pipe connected to the sink tap.
Recommendation: The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 08
Site: Potable Water-Potable Water Tank 1 Starboard
Violation: There was no documentation from either the Water Research Centre, Great Britain or the Norwegian Institute of Public Health that the Hempadur 85671 two part epoxy (85675 base and 97371 curing agent) which was applied to potable water tank #1 starboard on 9 September 2010 was approved for potable water tank coating. Both of the above references listed by the Hempel manufacturer were reviewed by internet during the inspection and no such certification/approval information was found.
Recommendation: Ensure that interior coatings on potable water tanks are approved for potable water contact, and all manufacturer's recommendations for application, drying, or curing are followed. Ensure written documentation for the coating used and recommendations followed are available for review during inspections.
Item No.: 10
Site: DO NOT USE (whirlpool/spa)-Hydropool - Deck 9
Violation: There was a daily notation in the pool and spa logs that the hydropool was disinfected, but there was no notation of either the concentration or contact time for shock halogenation.
Recommendation: The spa pool halogen shall be operated and maintained according to whirlpool spa standards provided in sections 6.3.1.1.1 - 6.4.1.3.1, except that daily water change in section 6.3.1.2 is not required. If the spa pool uses only seawater, the daily shock in section 6.3.2.1.2 is also not required. Ensure that a written or electronic record of whirlpool spa filter inspection, backwashing, core sample sedimentation test, and shock halogenation (concentration and contact time) is maintained and available for review during inspections.
Item No.: 10
Site: DO NOT USE (whirlpool/spa)-Hydropool - Deck 9
Violation: There were two suction fittings on the lower side section of the hydropool. The stainless steel grate covers did not meet the safety requirements of ASME/ANSI A112.19.8M or an equivalent standard.
Recommendation: Ensure that anti-entrapment drain covers or other drains that prevent entrapment hazards as specified in U.S. Consumer Product Safety Publication 363-009801 (dual drains/channel drains) are provided on swimming pools and whirlpool spas. Ensure that drain covers have either the plumbing/engineering approving organization stamp and flow rate affixed to the cover, or that a letter is maintained aboard the vessel certifying that the cover meets the safety requirements outlined in AMSE/ANSI A112.19.8M or an equivalent standard.