Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: AIDAluna Cruise Line: Aida Cruises Inspection Date: 10/03/2010 Inspection Score: 95
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 33
Site: Buffet-Deck 9 Market Restaurant
Violation: The wooden bulkhead panels at the beer/juice and post mix (soda) beverage stations has small square voids in the pattern with no access for cleaning behind the panels. Dirt debris was present along the lower voids and the space behind. Above the wood bulkheads a decorative false tree leaf material is glued to the bulkhead. These decorative leaves are not durable, hard or easy to clean.
Recommendation: Recommend addition of a solid panel behind the void panel bulkhead to prevent dirt debris from settling behind. Remove completely the artificial leaf type decorative bulkhead material and ensure the resulting panels are hard, durable, non-absorbent to be easy to clean.
Item No.: 20
Site: Food Service General-All Food Area Pepsi Post Mix Stations
Violation: The six soda/water dispenser heads on all the Pepsi Post Mix Stations have 4 slot-head screw fasteners on the underside (splash zone) of the dispenser.
Recommendation: Contact the equipment manufacturer to have their technicians evaluate this issue and provide a solution, so the slotted screw heads are not subject to splash or a non-slotted low-profile screw fastener is used on the dispensing heads.
Item No.: 20
Site: Buffet-Deck 9 Market Restaurant - Tea Station
Violation: The self-serve bulk milk dispenser tube was 2 inches in length and the serving end was not cut on a diagonal.
Recommendation: Ensure that the bulk milk container dispensing tube is cut on the diagonal leaving no more than 25mm (1 inch) protruding from the chilled dispensing head.
Item No.: 27
Site: Buffet-Deck 9 and 10 Buffet Areas - Decorative Displays
Violation: Some level of dust soil was observed on many of the decorative displays found in excess hanging from deckheads and bulkheads, and mostly those set on the overshelf of the buffet counters. The decorations included wicker baskets set alone or stacked, baskets containing imitation plants, vegetables, and flowers, hanging dried eggplant and tomatoes on strings, imitation long grass, and Asian lanterns. The common problem with all the above decorations was their materials and design was not easy to clean.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Buffet-Deck 9 and 10 Buffet Areas - Decorative Displays
Violation: Some level of dust soil was observed on many of the decorative displays found in excess hanging from deckheads and bulkheads, and mostly those set on the overshelf of the buffet counters. The decorations included wicker baskets set alone or stacked, baskets containing imitation plants, vegetables, and flowers, hanging dried eggplant and tomatoes on strings, imitation long grass, and Asian lanterns. The common problem with all the above decorations was their materials and design was not easy to clean.
Recommendation: Since these decorations are set on counters over clean plates and food displays or hanging from bulkheads and deckheads over these food and equipment surfaces, they should be evaluated for their material and ease of cleaning. The more solid, glass bottle style decorations were found easy to clean and all observed were clean.
Item No.: 21
Site: Food Service General-Main, Crew, and Buffet Show Galleys
Violation: The flat-top grills and grooved griddles had gaps around where the grease pan chute penetrated the underside of the panel in the undercounter technical compartment below.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Profile closed the gap along the underside panel where the grease chute penetrates.
Item No.: 20
Site: Buffet-Deck 9 Market Restaurant - Cheese Station
Violation: A set of slate stone individual cheese trays were stacked wet inside the back bar undercounter storage shelves. Upon inspection it was found that these stone trays were chipped and broken along all the outer edges and one side was clearly jagged with fractures throughout. Staff stated that the smoother side was used for placing cheeses, but in most trays the smoother side as well was not smooth and contained raised edges were the stone was at some time cracked or fractured along the surface. Two of these previously cleaned trays had an orange cheese debris on the rough side surface. Staff could not provide written evidence these stone trays were approved for food-contact.
Recommendation: Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition. Ensure that multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches. Ensure that food-contact surfaces of food equipment complies with American National Standards Institute (ANSI) or other internationally accredited food-equipment sanitation standards for materials, design, and construction.
Item No.: 28
Site: Buffet-Deck 9 Market Restaurant - Cheese Station
Violation: A set of slate stone individual cheese trays were stacked wet inside the back bar undercounter storage shelves. Upon inspection it was found that these stone trays were chipped and broken along all the outer edges and one side was clearly jagged with fractures throughout. Staff stated that the smoother side was used for placing cheeses, but in most trays the smoother side as well was not smooth and contained raised edges were the stone was at some time cracked or fractured along the surface. Two of these previously cleaned trays had an orange cheese debris on the rough side surface. Staff could not provide written evidence these stone trays were approved for food-contact.
Recommendation: After cleaning and sanitizing, ensure that equipment and utensils are air-dried or adequately drained before contact with food.
Item No.: 26
Site: Buffet-Deck 9 Market Restaurant - Cheese Station
Violation: A set of slate stone individual cheese trays were stacked wet inside the back bar undercounter storage shelves. Upon inspection it was found that these stone trays were chipped and broken along all the outer edges and one side was clearly jagged with fractures throughout. Staff stated that the smoother side was used for placing cheeses, but in most trays the smoother side as well was not smooth and contained raised edges were the stone was at some time cracked or fractured along the surface. Two of these previously cleaned trays had an orange cheese debris on the rough side surface. Staff could not provide written evidence these stone trays were approved for food-contact.
Recommendation: Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 33
Site: Buffet-Deck 9 Market Restaurant - Appetizer Line Port
Violation: The bulkhead behind this line was a very rough surface which made cleaning difficult.
Recommendation: Ensure that bulkheads and deckheads have smooth, hard finishes, and light colored surfaces.
Item No.: 21
Site: Buffet-Deck 9 Market Restaurant - Ham Station and Deck 10 Orient Station
Violation: The Berkel Slicer at the preparation counter in the ham station deck 9 and orient station deck 10 was set on 1/2 inch high legs and both were too difficult to move easily to clean below.
Recommendation: Ensure that table-mounted equipment that is not easily movable is installed to allow cleaning of the equipment and areas underneath and around the equipment by being: (1) Sealed to the table; or (2) Elevated on legs.
Item No.: 27
Site: Galley-Deck 9 Market Show Galley
Violation: There was an accumulation of a thick black debris in the lower technical compartment beside the undercounter refrigeration unit below the stone counter. Additionally, there was water standing in the rear deck of the compartment behind the deck sink. It's possible the drain hose to the deck sink was draining into this section because it did not fully extend into the deck sink.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 26
Site: Galley-Main Galley - Coffee Station
Violation: One of the previously cleaned portable bulk coffee dispensers had a heavy, old coffee residue along the inside of the gasket on the dispensing head. Staff removed this and cleaned it immediately.
Recommendation: Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 23
Site: Galley-Main Galley - Dishwash
Violation: The in-use flight-type conveyor dishwash machine had a wash tank water temperature of only 140 °F, while the manufacturer's data plate specified a minimum wash tank temperature of 160 °F.
Recommendation: Ensure that the temperature of the wash solution in spray type warewashers that use hot water to sanitize is not less than: (1) For a stationary-rack, single-temperature machine, 74°C (165°F); (2) For a stationary-rack, dual-temperature machine, 66°C (150°F); (3) For a single-tank, conveyor, dual-temperature machine, 71°C (160°F); or (4) For a multitank, conveyor, multitemperature machine, 66°C (150°F).
Item No.: 18
Site: Galley-Main Galley - Dry Storage Corridor
Violation: Dried spatzle was found on the dry storage shelf with one of the bags open. The others were not fully sealed shut. Staff transferred the product immediately to covered plastic bins.
Recommendation: Ensure that food is protected from cross-contamination by: (6) Protecting food containers that are received packaged together in a case or overwrap from cuts when the case or overwrap is opened.
Item No.: 20
Site: Food Service General-All Crushed Ice Machines
Violation: There was a difficult to clean seam present in all the ice machine lower bins between the ice chute and the plastic pipe which discharged the ice into the lower bin. Additionally, the pipe did not extend fully into the bin, and the exposed edge of the ice chute surrounding was soiled with a mold residue which contacted the ice from the pipe end.
Recommendation: Seal the seam along the pipe penetration and the ice chute with a product that is approved for food-contact and maintain documentation of that products approval.
Item No.: 26
Site: Food Service General-All Crushed Ice Machines
Violation: There was a difficult to clean seam present in all the ice machine lower bins between the ice chute and the plastic pipe which discharged the ice into the lower bin. Additionally, the pipe did not extend fully into the bin, and the exposed edge of the ice chute surrounding was soiled with a mold residue which contacted the ice from the pipe end.
Recommendation: Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 16
Site: Galley-Main Galley - Hot Galley
Violation: Cooked ratatouille was being transferred to hotel pans for placement on the buffet hot hold lines, but the food temperature was between 118 and 133 °F. Staff returned all 4 pans to the tilt braising pan for re-heating.l
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
Item No.: 26
Site: Galley-Main Galley - Hot Galley
Violation: A previously cleaned tilt braising pan was turned on for pre-warming. The pan had significant brown food sediment on the bottom interior surface. When the cook preparing the pan was questioned, he stated that he was preparing the pan to cook rabbit. The operation was stopped immediately and a staff member brought three buckets in two begin manual warewashing of this pan.
Recommendation: Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 13
Site: Galley-Main Galley - Hot Galley
Violation: A previously cleaned tilt braising pan was turned on for pre-warming. The pan had significant brown food sediment on the bottom interior surface. When the cook preparing the pan was questioned, he stated that he was preparing the pan to cook rabbit.
Recommendation: Person in charge: Ensure that employees are properly sanitizing cleaned multiuse equipment and utensils before they are reused, through routine monitoring of solution temperature and exposure time for hot water sanitizing, and chemical concentration, pH, temperature, and exposure time for chemical sanitizing.
Item No.: 17
Site: Galley-Main Galley - Hot Galley
Violation: A sheet pan of cooked spicy ribs was found inside the walk-in refrigerator with a preparation date of 29 September, but there was no cooling log entry for these ribs on 29 September.
Recommendation: Ensure that logs documenting cooked, potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days form the date the food was placed in the cooling process. Ensure that logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 26
Site: Galley-Main Galley - Sushi/Appetizer Preparation Counter
Violation: A previously cleaned long portable electic probe blender was found stored clean on the overshelf of the sushi and appetizer preparation counter. There was milky colored liquid residue on the blender blades which began dripping away from the blades as the piece was lifted up for inspection. Staff returned the blender to the pot wash for re-cleaning.
Recommendation: Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 16
Site: Galley-Deck 10 Galley - Cold Galley
Violation: One tray of opened and cut cheeses was stored in upright reach-in refrigerator #11 with no discard label.
Recommendation: Ensure that refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours is clearly marked at the time of preparation to indicate the date or day by which the food shall be consumed, which is 7 calendar days or fewer from the day the food is prepared with the day of preparation counting as day 1. (2) A container of refrigerated, ready-to-eat potentially hazardous food prepared and packaged by a food processing plant and held on the vessel after opening more than 24 hours is clearly marked, at the time the original container is opened, to indicate the date by which the food shall be consumed which is, including the day the original container is opened, 7 calendar days or fewer after the original container is opened. The day of opening is counted as day 1.
Item No.: 33
Site: Other-Deck 10 Pizzeria
Violation: There was no coving at the deck to bulkhead juncture along the back bulkhead in the pizzeria.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 20
Site: Galley-Crew Galley - Pot Wash
Violation: One red and one green cutting board found in the pot wash clean rack had heavy scoring and loose plastic from the food-contact surfaces which required re-surfacing of each.
Recommendation: Ensure that surfaces such as cutting blocks and boards that are subject to scratching and scoring are resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
Item No.: 24
Site: Galley-Crew Galley - Pot Wash
Violation: One staff member was observed dipping some of the cleaned pans in the chemical sanitizing sink water for only 4 seconds, rather than the required 7 seconds.
Recommendation: Ensure that the chemical sanitizer is used in accordance with the EPA-approved manufacturer's label use instructions at a minimum temperature of 24°C (75°F) with an exposure time of 7 seconds for a chlorine solution and 30 seconds for other chemical sanitizers.
Item No.: 15
Site: Galley-Crew Galley - Dry Stores Racks
Violation: One 4.5kg can of tomato paste was severely dented, with pinched metal along the lower section near the bottom seam and stored on the dry storage rack in the galley.
Recommendation: Ensure that food packages are in good condition and protect the integrity of the contents so that the food is not exposed to adulteration or potential contaminants. Ensure that canned goods with dents on end or side seams are not used.
Item No.: 36
Site: Buffet-Crew Mess
Violation: There was less than the minimum 220 lux of artificial light over the port/aft corner of the buffet where the two plate dispensers are positioned.
Recommendation: Ensure that the light intensity is at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 02
Site: Medical-Medical Specimen Shipping Containers
Violation: The specimen shipping containers did not have all the correct labels for shipping.
Recommendation: Ensure that at least 10 clinical specimen collection containers for both viral and bacteriological agents (10 each), as well as the proper shipping containers and labels for same, are maintained by the medical staff.
Item No.: 27
Site: Preparation Room-Deck 3 - Fish
Violation: The stainless cart used for the smoker was soiled--especially along the seams.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Preparation Room-Deck 3 - Fish
Violation: The stainless steel cart had gaps and seams that were difficult to clean.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 22
Site: Bar-Pool Bar
Violation: The hood-type warewashing machine did not have a dataplate.
Recommendation: Ensure that warewashing machines are provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
Item No.: 33
Site: Bar-Pool Bar
Violation: The deck for the waste station was not easily cleanable, and was not coved.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters). Ensure that surfaces subject to routine splashes, spillage, or other soiling during normal use have easily cleanable features.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program