Cruise Ship: Amadea Cruise Line: Bernhard Schulte Cruise Services GmbH & Co. KG Inspection Date: 10/12/2010 Inspection Score: 91
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 02
Site: Medical-
Violation: There were no shipping containers or shipping container labels on the vessel. This was cited during the last inspection.
Recommendation: Ensure that at least 10 clinical specimen collection containers for both viral and bacteriological agents (10 each), as well as the proper shipping containers and labels for same, are maintained by the medical staff.
Item No.: 07
Site: Potable Water-Foward Reserve Tanks Port and Starboard
Violation: The two tanks share an outside wall with the hull of the vessel. This was noted on the previous inspection.
Recommendation: Ensure that potable water tanks do not share a common wall with the hull of the vessel or with tanks containing non-potable water or other liquids.
Item No.: 07
Site: Potable Water-Tanks
Violation: The four forward tanks (reserve port, reserve starboard, 1S and 1P) share a common wall with ballast water tank #2 (holding mixed ballast and gray water).
Recommendation: Ensure that potable water tanks do not share a common wall with the hull of the vessel or with tanks containing non-potable water or other liquids.
Item No.: 08
Site: Potable Water-Tank Coatings
Violation: Maintenance on tanks 1P, 1S, 2P, 2S, 3P, 3S, reserve port, and reserve starboard was completed at dry dock in December 2009. There was no written independent documentation that the tank coating (Chugoku Bannon 200) and paint (Jotastic 87 and Tankguard 412) used were certified for potable water use. The manufacturer's literature cites certification approval, however, the approval could not be verified. This was noted in the last inspection.
Recommendation: Ensure that interior coatings on potable water tanks are approved for potable water contact, and all manufacturer's recommendations for application, drying, or curing are followed. Ensure written documentation for the coating used and recommendations followed are available for review during inspections.
Item No.: 08
Site: Potable Water-Tank Coatings
Violation: Maintenance on tanks 1P, 1S, 2P, 2S, 3P, 3S, reserve port, and reserve starboard was completed at dry dock in December 2009. There was no written documentation that the tank coating (Chugoku Bannon 200) and paint (Jotastic 87 and Tankguard 412) used were applied and cured per the manufacturer's recommendations.
Recommendation: Ensure that interior coatings on potable water tanks are approved for potable water contact, and all manufacturer's recommendations for application, drying, or curing are followed. Ensure written documentation for the coating used and recommendations followed are available for review during inspections.
Item No.: 08
Site: Potable Water-Tank Cleaning and Disinfection
Violation: On September 17, tanks 2P, 2S, reserve starboard, and reserve port were inspected. There was no documentation that the halogenation level was 5ppm or less prior to the tanks being put back on line.
Recommendation: Ensure that the disinfected parts of the system are flushed with potable water until the free residual halogen is at or below 5.00 mg/L (ppm).
Item No.: 08
Site: Potable Water-
Violation: There was no record of testing for the reduced pressure assembly backflow prevention devices on the deck 2 evaporators.
Recommendation: Ensure that backflow prevention devices requiring testing, for example reduced pressure backflow preventer and double check valves with test cocks, are inspected and tested with a test kit at least annually and that the test results showing the pressure differences on both sides of the valves are maintained for each device.
Item No.: 08
Site: Potable Water-Main Laundry
Violation: The potable water lines for the washers had single check valve backflow prevention devices without intermediate atmospheric vents.
Recommendation: Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
Item No.: 08
Site: Potable Water-Crew Laundry
Violation: There were no backflow prevention devices on the washers.
Recommendation: Ensure that backflow preventers are installed when air gaps are impractical or when water under pressure is required.
Item No.: 08
Site: Potable Water-Fire Hose Locker 7-5
Violation: There was no backflow prevention device on the potable water line used to clean the decks.
Recommendation: The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 08
Site: Potable Water-Spa
Violation: There were no backflow prevention devices on the hair sinks or the steam generator/aroma therapy unit.
Recommendation: The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 08
Site: Potable Water-Deck 10 Pool Pump Room
Violation: The air gap on the potable water line to the whirlpool make-up tank was not at least twice the diameter of the delivery fixture.
Recommendation: Ensure that air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 3 cm (1 inch).
Item No.: 08
Site: Potable Water-Deck 10 Pool Pump Room
Violation: An air gap was used as the backflow prevention method for the potable water line to the make-up tank. The air gap was not in the cross-connection control program listing.
Recommendation: Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing.
Item No.: 08
Site: Medical-X-ray Developing Room
Violation: There was no backflow prevention device installed on the sink. A laboratory water testing apparatus was installed on the faucet which extended below the flood rim level of the sink.
Recommendation: The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 10
Site: DO NOT USE (whirlpool/spa)-
Violation: There was no anti-entrapment drain cover on the whirlpool drain.
Recommendation: Ensure that anti-entrapment drain covers or other drains that prevent entrapment hazards as specified in U.S. Consumer Product Safety Publication 363-009801 (dual drains/channel drains) are provided on swimming pools and whirlpool spas. Ensure that drain covers have either the plumbing/engineering approving organization stamp and flow rate affixed to the cover, or that a letter is maintained aboard the vessel certifying that the cover meets the safety requirements outlined in AMSE/ANSI A112.19.8M or an equivalent standard.
Item No.: 16
Site: Galley-Deck 5 - Cold Galley - Reach-In Refrigerator No. 1
Violation: The internal temperature of three pieces of ready-to-eat liver ranged between 47°F (8°C) and 52°F (11°C). The liver had a open date of 10 October 2010. According to the staff, the liver was just placed into the reach-in. The liver was immediately placed into the blast chiller.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
Item No.: 16
Site: Galley-Deck 5 - Cold Galley - Refrigerator No. 28
Violation: A few large pans of pasta salad with ham had temperatures that ranged between 48°F (8°C) and 54°F (12°C). According to the staff, the pasta was produced and chilled the previous day. There was no record of the cooling of the pasta. The pasta was discarded.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
Item No.: 19
Site: Buffet-Deck 8 - Aft - Amadea Restaurant - Cold Top
Violation: The two cold top units did not have side shields installed.
Recommendation: Install side shields.
Item No.: 19
Site: Buffet-Deck 8 - Aft - Amadea Restaurant - Tea Station
Violation: The tea station did not have side shields installed.
Recommendation: Install side shields.
Item No.: 21
Site: Provisions-Deck 3 - Forward - Dry Storage
Violation: The storage shelves were constructed of raw, unfinished wood.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 21
Site: Galley-Deck 5 - Tilting Pans and Kettles
Violation: The round handle for the tilting pans and kettles had a grove on the back side of the handle that was not easily cleanable.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-Deck 5 - Pot Wash
Violation: The insulation for the water supply lines for the pot wash machine had difficult to clean features and were soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 21
Site: Galley-Deck 5 - Hot Galley - Fryers
Violation: There was an open, difficult to clean gap between the single and double deep fat fryers. The gap space was heavily soiled with food residue and old grease.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-Deck 5 - Hot Galley - Hot Plates
Violation: There was a difficult to clean, open seam between the two hot plates. This space was heavily soiled with grease, dust and food residue.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-Deck 5 - Hot Galley - Preparation Tables
Violation: There was an open, difficult to clean seam between the two preparation tables. This space was soiled with grease, dust and food residue.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-Deck 5 - Hot Galley - Small Combination Ovens
Violation: There were two braided hoses beneath the ovens. The hoses were soiled with old grease.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 21
Site: Galley-Deck 5 - Hot Galley - Grill/Hot Plate
Violation: The front panel of the two grill/hot plate units had several holes and open seams, making cleaning difficult. The front surfaces and technical compartments behind the drip pan housing were heavily soiled with grease and food residue.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Bar-Deck 10 - Vista Lounge
Violation: The seal between the pieces of bar counter had separated, creating a difficult to clean surface.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Galley-Deck 5 - Hot Galley - Grill/Hot Plate
Violation: The front panel of the two grill/hot plate units had several holes and open seams, making cleaning difficult. The front surfaces and technical compartments behind the drip pan housing were heavily soiled with grease and food residue.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-Deck 5 - Hot Galley - Small Combination Ovens
Violation: There were two braided hoses beneath the ovens. The hoses were soiled with old grease.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-Deck 5 - Hot Galley - Preparation Tables
Violation: There was an open, difficult to clean seam between the two preparation tables. This space was soiled with grease, dust and food residue.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-Deck 5 - Hot Galley - Hot Plates
Violation: There was a difficult to clean, open seam between the two hot plates. This space was heavily soiled with grease, dust and food residue.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-Deck 5 - Hot Galley - Fryers
Violation: There was an open, difficult to clean gap between the single and double deep fat fryers. The gap space was heavily soiled with food residue and old grease.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-Deck 5 - Pot Wash
Violation: The insulation for the water supply lines for the pot wash machine had difficult to clean features and were soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Food Service General-Decks
Violation: There was recessed grout, broken tiles/missing tiles in numerous food service preparation and storage areas. The deck surface was rough and not easily cleanable in many locations under equipment and in technical spaces. The decks under several pieces of equipment and in numerous technical spaces was soiled with grease, food residue and dust.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Galley-Deck 5 - Hot Galley - Fryers
Violation: The deck below the deep fat fryers was rough, difficult to surface. There deck was soiled with grease and food debris.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning. Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Provisions-Deck 3 - Forward - Dry Storage
Violation: The deck below the dry storage shelves had an accumulation of a dry brown/black sticky substance.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Buffet-Deck 8 - Amadea Restaurant - Buffet Lines - Server Side
Violation: There was no coving at the deck/counter juncture at the service lines, buffet islands and waiter stations.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 33
Site: Buffet-Deck 8 - Aft - Amadea Restaurant - Tea Station
Violation: The stainless steel backsplash next to the handwashing station was separating from the bulkhead, creating a large gap, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Galley-Deck 9 - Copernikus Bar
Violation: The bar counter was separating from the bulkhead, creating a void space.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 36
Site: Food Service General-Artificial Lighting
Violation: The artificial light intensity for several food preparation and storage areas was insufficient to facilitate proper cleaning, sanitation, and hygiene. Some areas observed included but were not limited to, walk-in refrigerators and freezers; warewash machines; food preparation counters; bars; and handwash stations.
Recommendation: Ensure that the light intensity is at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas. Ensure that the light intensity is at least 110 Lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure that the light intensity is at least 220 Lux (20 foot candles) in bars and at dining room waiter stations during periods of cleaning.
Item No.: 37
Site: Galley-Deck 5 - Hot Line - Service Counter
Violation: There was condensate along the underside of the baine marie overshelf. No condensate was observed dripping from the self.
Recommendation: Ensure that all food preparation, warewashing, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
Item No.: 38
Site: Galley-Deck 5 - Bakery / Pastry
Violation: The dough press machine for rolls was labeled out of service. According to the staff, the unit had been out of service for an undetermined period of time.
Recommendation: Ensure that only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 38
Site: Galley-Deck 5 - Bakery / Pastry
Violation: The proofing box immediately adjacent to the dough press was labeled out-of-order. According to the staff, the proofing box had been out of service for an undetermined period of time.
Recommendation: Ensure that only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 40
Site: Integrated Pest Management-
Violation: The IPM plan had not been evaluated for effectiveness every two years. The IPM plan was dated June 8, 2007.
Recommendation: Ensure that the vessel's Integrated Pest Management Plan is evaluated for effectiveness every 2 years or whenever there is a significant change in the vessel's structure such as a renovation or operation.
Item No.: 40
Site: Integrated Pest Management-
Violation: The logs only had columns to record what pests were observed in the traps (passive). There was no place to log sightings by crew or passengers other than a narrative block. This prevented staff from viewing patterns of sightings (locations) and type of sightings (adult, nymph, larvae, etc).
Recommendation: Include in IPM program, a pest sighting log.
Item No.: 40
Site: Integrated Pest Management-Training
Violation: The IPM plan had 8 staff training plan modules. During the last training cycle, modules 7 and 8 (computer logging and provisions inspections) were not completed by any staff.
Recommendation: Ensure all training modules are completed.