|
|
|
Item No.:
21
|
|
Site:
Dining Room-Discovery Restaurant
|
|
Violation:
There was damaged wood surfaces on the drawer fronts and interiors of all the waiter stations in the dining room. The exposed wood was raw and absorbent. The lower doors also had peeling laminate exposing a raw wood underlayer. Staff noted a project for the renovation was planned.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment and utensils are designed and constructed to be durable and to retain their characteristic qualities under normal use conditions.
|
|
|
Item No.:
21
|
|
Site:
Galley-Room Service Pantry - Beverage Counter
|
|
Violation:
The power cables and water supply tubes were draping on the counters below equipment such as coffee machines, espresso machines, and toaster oven.
|
|
Recommendation:
Elevate the power cables and water supply tubes so the area under equipment can be easily cleaned.
|
|
|
Item No.:
21
|
|
Site:
Galley-Main Galley - Pastry
|
|
Violation:
The power cable for the counter mounted bread slicer was draped on the counter making cleaning difficult.
|
|
Recommendation:
Elevate the power cable of the bread slicer.
|
|
|
Item No.:
16
|
|
Site:
Galley-Main Galley - Hot Galley
|
|
Violation:
A large plastic bin of cut, raw spinach was found inside walk-in refrigerator #4d068 with a food temperature between 43 and 45 °F. It was removed immediately and cooled with ice.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
|
|
|
Item No.:
22
|
|
Site:
Galley-Main Galley - Dishwash
|
|
Violation:
The in-use flight-type conveyor dishwasher had the center upper pre-rinse spray nozzle completely clogged, the far right upper arm spray nozzle clogged and the third upper arm final rinse spray nozzle clogged. This was repaired during the inspection.
|
|
Recommendation:
Ensure that warewashing equipment is maintained in good repair and proper adjustment including: (1) Being maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; and (2) Maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
|
|
|
Item No.:
22
|
|
Site:
Galley-Main Galley - Dishwash
|
|
Violation:
During active use of the flight-type conveyor dishwash machine it was noted that the mounted pre-wash thermometer registered 164 °F, but the tank temperature was measured at 145 °F. The wash gauge displayed 162 °F, but the wash tank temperature measured only 147 °F. There was also a conflict with the content on the wash thermometer gauge and the data plate on this machine, as the gauge required a 150 °F minimum temperature, but the mounted data plate specified a minimum 160 °F wash temperature.
|
|
Recommendation:
Ensure that warewashing machines and their auxiliary components: (1) Are operated in accordance with the machine's data plate and other manufacturer's instructions. (2) A warewashing machine's conveyor speed or automatic cycle times are maintained accurately timed in accordance with manufacturer's specifications.
Verify the correct wash temperature and ensure only one is displayed on the machine.
|
|
|
Item No.:
20
|
|
Site:
Food Service General-Beverage Stations
|
|
Violation:
There were two slot-head screws fastened into the upper interior of the ice dispensing chute on all the Hoshizaki ice and water dispensers in the beverage stations throughout the ship. The screws were corroding and soiled in most cases.
|
|
Recommendation:
Contact the manufacturer about changing the screw type in all these machines.
|
|
|
Item No.:
26
|
|
Site:
Food Service General-Beverage Stations
|
|
Violation:
There were two slot-head screws fastened into the upper interior of the ice dispensing chute on all the Hoshizaki ice and water dispensers in the beverage stations throughout the ship. The screws were corroding and soiled in most cases.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch. Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
21
|
|
Site:
Buffet-Crew Mess Beverage Station
|
|
Violation:
The power cable was draped on the counter below the ice and water dispenser.
|
|
Recommendation:
Elevate the power cable to the ice and water dispenser.
|
|
|
Item No.:
22
|
|
Site:
Galley-Crew Galley - Dishwash
|
|
Violation:
The in-use conveyor dishwash machine had a final sanitizing rinse water pressure of 40 psi. The manufacturer specifies a fresh water final sanitizing rinse pressure of 15-25 psi.
|
|
Recommendation:
Ensure that warewashing machines and their auxiliary components: (1) Are operated in accordance with the machine's data plate and other manufacturer's instructions. (2) A warewashing machine's conveyor speed or automatic cycle times are maintained accurately timed in accordance with manufacturer's specifications.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Medical Center
|
|
Violation:
The incubator for the potable water analysis for fecal coliform bacteria was operating at 38.5 °C. The onboard test kit specifies the range of the incubator to be 35 °C with a range of plus or minus 0.5 °F.
|
|
Recommendation:
Recommend another model incubator which allows more fine adjustment within the range of use.
|
|
|
Item No.:
10
|
|
Site:
DO NOT USE (whirlpool/spa)-Thalassotherapy Pool Aft
|
|
Violation:
There was no health warning sign posted to warn against use by particular susceptible people, such as those who are immunocompromised.
|
|
Recommendation:
Ensure that a sign is installed near the whirlpool spas that lists standard safety precautions and risks, warning against use by particularly susceptible people, such as those who are immunocompromised.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Production
|
|
Violation:
The written record of the calibration check at the start of potable water production was not made consistently since the last VSP inspection.
|
|
Recommendation:
Ensure that halogen analyzer-chart recorders used in lieu of manual tests and logs are calibrated at the beginning of bunkering or production, and the calibration is recorded on the chart or in a log book.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross-Connection Control Program
|
|
Violation:
The deck 2 midship chemical dispensing locker dispenser connections were not listed with the other areas where backflow preventers were installed. Additionally, for a number of the devices in engine and other spaces, the record only listed the location and not the equipment the backflow preventer was connected to.
|
|
Recommendation:
Include the chemical dispensing station in the listing and inspection of backflow preventers. Edit the current listing and ensure that for each location the plumbed assembly or piece of equipment is identified.
|
|
|
Item No.:
33
|
|
Site:
Other-Deck 9 Grill Area - Aft Beverage Station
|
|
Violation:
The deckhead over this beverage station was a difficult to clean, soft sailcloth material.
|
|
Recommendation:
Ensure that bulkheads and deckheads have smooth, hard finishes, and light colored surfaces.
|
|
|
Item No.:
33
|
|
Site:
Other-Sunset Verandah - Beverage Station
|
|
Violation:
The deckhead over the beverage station was a difficult to clean, soft sailcloth material.
|
|
Recommendation:
Ensure that bulkheads and deckheads have smooth, hard finishes, and light colored surfaces.
|
|
|
Item No.:
16
|
|
Site:
Galley-Windows Cafe Galley
|
|
Violation:
The written time as a public health control plan listed a hot Alto-Shaam cabinet as a hot holding step under time control for back-up foods for the buffet line. The staff noted that this was not used, but the large combination oven in the windows cafe galley was the time control holding unit for all foods prepared there. This unit was not on the written time control plan.
|
|
Recommendation:
Ensure that the time only as a public health control program identifies the hot holding units where only time control is used.
|
|
|
Item No.:
21
|
|
Site:
Bar-Sunset Verandah - Bar
|
|
Violation:
The bar top stone surface was damaged throughout from pitting of the top surface, leaving a rough, uneven, and difficult to clean surface.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|