|
|
|
Item No.:
33
|
|
Site:
Food Service General-Decks
|
|
Violation:
The decks throughout the galleys and warewash areas had recessed and missing deck grout, especially at pipe penetrations, deck mounts, deck sinks, and gutterways. The painted decks inside technical spaces were rough.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
24
|
|
Site:
Bar-Moby Dick
|
|
Violation:
There was a bucket of sanitizing solution that was measured at greater than 200 ppm chlorine. The bucket was fresh and not in use. The sanitizing solution was discarded.
|
|
Recommendation:
Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
|
|
|
Item No.:
24
|
|
Site:
Bar-Venise Bar
|
|
Violation:
There was a bucket of sanitizing solution that was measured at greater than 200 ppm chlorine. The bucket was fresh and not in use. The sanitizing solution was discarded.
|
|
Recommendation:
Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
|
|
|
Item No.:
30
|
|
Site:
Pantry-Venise Bar
|
|
Violation:
The handwash station had a self closing faucet. The flow of water lasted only 7 seconds.
|
|
Recommendation:
Ensure that self-closing, slow-closing, or metering faucets provide a flow of water for at least 15 seconds without the need to reactivate the faucet.
|
|
|
Item No.:
33
|
|
Site:
Dining Room-Magellan
|
|
Violation:
The deck/cabinet juncture was not coved at the waiter station in the center by the wine cooler or at the port/aft waiter station.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
|
|
|
Item No.:
21
|
|
Site:
Dining Room-Magellan
|
|
Violation:
At the right end of the starboard/aft waiter station, there was a gap under the edge of the counter and a hole under the lower edge of the cabinet.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
36
|
|
Site:
Dining Room-Magellan
|
|
Violation:
The lighting could not be raised to 220 lux on the surfaces of the starboard/aft and long center waiter stations.
|
|
Recommendation:
Ensure that the light intensity is at least 220 Lux (20 foot candles) in bars and at dining room waiter stations during periods of cleaning.
|
|
|
Item No.:
19
|
|
Site:
Buffet-Mediterranea
|
|
Violation:
At the aft buffet counter, there was a pan of open containers of condiments such as oils, vinegars, salt and pepper in the same small neutral cabinet as menus, alcohol wipes, and other non-food items. The pan of condiments was removed.
|
|
Recommendation:
Ensure that food is protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Mediterranea
|
|
Violation:
At the aft buffet counter, there was an unsealed bulkhead penetration below the counter with the coffee machine.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
36
|
|
Site:
Dining Room-Mediterranea
|
|
Violation:
The lighting could not be raised to 220 lux at the inside and outside waiter stations by the aft buffet line or at the forward/port waiter station.
|
|
Recommendation:
Ensure that the light intensity is at least 220 Lux (20 foot candles) in bars and at dining room waiter stations during periods of cleaning.
|
|
|
Item No.:
28
|
|
Site:
Galley-Mediterranea Warewashing
|
|
Violation:
There were three racks of inverted clean bowls and small plates on a deck stand between the clean and dirty ends of the dishwash machine. When racks were handed from the clean to the dirty end of the machine, water would drip onto the racks.
|
|
Recommendation:
Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 150 mm (6 inches) above the deck.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Mediterranea Forward
|
|
Violation:
There was less than 220 lux of light at the new ice and water dispensers.
|
|
Recommendation:
Ensure that the light intensity is at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
33
|
|
Site:
Galley-Mediterranea
|
|
Violation:
The deck was soiled below the mounts for the counter under the utility sink.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
27
|
|
Site:
Galley-Mediterranea
|
|
Violation:
The counter was soiled below and behind the grill.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
21
|
|
Site:
Galley-
|
|
Violation:
The grease drain was not sealed in the top of the drip pan housing. This was noted throughout the galleys on the last inspection, but most grills were in operation during this inspection and the drip pan housing could not be viewed.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Galley-
|
|
Violation:
The turning handle for the left tilting kettle was soiled in the seam along the back of the handle.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
28
|
|
Site:
Galley-
|
|
Violation:
Two containers that previously contained herring were used to store salt and pepper.
|
|
Recommendation:
Ensure that single-service and single-use articles are not reused.
|
|
|
Item No.:
19
|
|
Site:
Galley-
|
|
Violation:
The containers of salt and pepper were not labeled with the contents.
|
|
Recommendation:
Ensure that working containers holding food or food ingredients that are removed from their original packages for use on the vessel, such as cooking oils, flour, herbs, potato flakes, salt, spices, and sugar are identified with the common name of the food.
|
|
|
Item No.:
28
|
|
Site:
Galley-Warewash
|
|
Violation:
There were stacks of clean plates on an upper shelf. The plates were not inverted.
|
|
Recommendation:
Ensure that clean equipment and utensils are stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
22
|
|
Site:
Galley-Magellan Warewash
|
|
Violation:
The data plate on the larger rack dishwash machine was worn and unreadable.
|
|
Recommendation:
Replace the data plate.
|
|
|
Item No.:
20
|
|
Site:
Preparation Room-
|
|
Violation:
There were slotted fasteners in the food contact area around the chute of the potato peeler.
|
|
Recommendation:
Remove the slotted fasteners and replace with smooth, low-profile, non-corroding fasteners.
|
|
|
Item No.:
30
|
|
Site:
Preparation Room-
|
|
Violation:
There was no trash can for the handwash station.
|
|
Recommendation:
Ensure that a handwashing facility includes a sink, soap dispenser, single-use towels dispenser, and waste receptacle.
|
|
|
Item No.:
21
|
|
Site:
Provisions-Ice Cream Freezer
|
|
Violation:
A soda crate was used as a deck stand.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
19
|
|
Site:
Provisions-Ice Cream Freezer
|
|
Violation:
The soda crate used as a deck stand did not elevate the food items at least 6 inches off the deck.
|
|
Recommendation:
Ensure that food is protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
27
|
|
Site:
Provisions-Dairy (BOF)
|
|
Violation:
The crates used to separating foods for issue were soiled on the outside.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Fecal Accident Plan
|
|
Violation:
A correct procedure was described by the crew, but there was no written fecal accident plan.
|
|
Recommendation:
Ensure that a fecal accident response procedure, which meets or exceeds the procedure provided in annex 13.11, is documented and available for review during inspections.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Crew Toilet
|
|
Violation:
In the crew public toilet that had the far point station, there was no means to exit without touching the handle of the door with bare hands.
|
|
Recommendation:
Equip public toilet facilities so that persons exiting the toilet room are not required to handle the door with bare hands. This may be accomplished by methods such as locating paper towel dispensers at sinks and waste containers near the room door, installing mechanically operated doors, door removal, or other effective means.
|
|
|
Item No.:
02
|
|
Site:
Medical-
|
|
Violation:
There were no specimen collection containers for bacteriological analysis.
|
|
Recommendation:
Ensure that at least 10 clinical specimen collection containers for both viral and bacteriological agents (10 each), as well as the proper shipping containers and labels for same, are maintained by the medical staff.
|
|
|
Item No.:
03
|
|
Site:
Potable Water-
|
|
Violation:
A comparison of the potable water production records and the ship's schedule indicated that the vessel was producing water while at anchor. Staff stated that the chart recorder was not turned off and the sample was recorded from water in the mixing tank even though no production was taking place while at anchor. For each time the ship was at a dock, there was no indication of production of water.
|
|
Recommendation:
Ensure that a reverse osmosis, distillation plant or other process that supplies water to the vessel's potable water system does not operate in polluted areas, harbors, or at anchor.
|
|