Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Ventura Cruise Line: P&O Cruises Inspection Date: 01/04/2011 Inspection Score: 99
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 21
Site: Food Service General-Galleys
Violation: There were open seams around the grooved and flat grill grease drain in the grease chute. Some of these areas were soiled. This was true for all grills of all galleys.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Food Service General-Galleys
Violation: There were open seams around the grooved and flat grill grease drain in the grease chute. Some of these areas were soiled. This was true for all grills of all galleys.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Galley-Beach House
Violation: There was a 4-inch gap where the pipes from refrigeration unit #4 penetrated the bulkhead.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Pantry-Dispense Bar / Deck 15
Violation: There was a gap where the pipe penetrated the deckhead in front of the carbonator compartment. The collar for the pipe had fallen loose.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 27
Site: Galley-East Galley / Cold Section
Violation: The deck was soiled under refrigeration units EF1 and EF2. This area was previously cleaned.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 22
Site: Galley-Play House Dishwash
Violation: During active use of the flight-type conveyor dishwashing machine, the far left nozzle of the wash spray arm had an ineffective spray pattern.
Recommendation: Ensure that the wash spray nozzles form an effective spray pattern.
Item No.: 27
Site: Galley-Hot Plate Counters / Deck 5
Violation: There were 16 sealed dial thermometers at these undercounter hot plate storage compartments; 15 out of the 16 had moisture and pooled water inside; 4 of these had also a heavy acumulation of mold inside.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Other-Frankie's Pizzeria
Violation: The deck below the dishwash machine was heavily soiled.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 19
Site: Provisions-Freezer Units
Violation: There were many instances where boxes containing food items were covered with ice, suggesting dripping from condensate.
Recommendation: Ensure that packaged food in the cold storage rooms are protected.
Item No.: 20
Site: Provisions-Vegetable Preparation Room
Violation: The inside of the 3 potato peelers contained slotted metal fasteners. One of these potato peelers was in use at the time of the inspection.
Recommendation: Remove the slotted fasteners and replace with smooth, low-profile, non-slotted fasteners.
Item No.: 19
Site: Provisions-Fruit and Vegetable Cooler
Violation: A mesh bag of red radishes was stored directly on the deck.
Recommendation: Ensure that food is protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 27
Site: Bar-Breakers Bar
Violation: The screw openings at the base of the beer dispenser were soiled. This bar was open at the moment of inspection.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Bar-Exchange Bar
Violation: The inside of the technical compartments at the starboard and port sides were heavily soiled in many areas. In addition, the refrigeration unit pipes at the starboard side were covered with mold. This bar was not open at the moment of inspection.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 11
Site: Medical-Crew Gastrointestinal Illness Reporting
Violation: A food and beverage assistant (FBAS) experienced gastrointestinal illness (GI) symptoms at 18:20 on 22 December 2010, but did not report the symptoms to the medical center until 1820 on 23 December. Additionally, only 1 of the remaining 3 cabin mates was contacted by medical for the required verbal interview to both confirm their condition and advise them on handwashing/hygiene and to report if they became ill. An officer had GI symptoms at 11:00 on 28 December and did not report to the medical center until 1700 on 29 December.
Recommendation: Ensure that symptomatic food employees meeting the case definition for AGE are isolated in cabin or designated, restricted area until symptom-free for a minimum of 48 hours.
Item No.: 02
Site: Medical-Clinical Specimen Collection
Violation: The supply of sterile tubes for specimen collection and analysis for bacterial agents expired on 20 November 2010. Staff stated that the new order was due to arrive on 14 January 2011.
Recommendation: Ensure that at least 10 clinical specimen collection containers for both viral and bacteriological agents (10 each), as well as the proper shipping containers and labels for same, are maintained by the medical staff.
Item No.: 08
Site: Potable Water-Medical Center - Ward #1
Violation: There was no backflow prevention device installed on the flexible shower hose in the ward room #1 toilet room. The hose was long enough to reach the deck.
Recommendation: Ensure that backflow preventers are installed when air gaps are impractical or when water under pressure is required.
Item No.: 40
Site: Integrated Pest Management-Training
Violation: The IPM Foundation Training from April 2010 included modules 1-6, but the staff involved with inspecting the provision stores for pests did not train on module 8, which is for provisions inspections.
Recommendation: Ensure that the staff involved in IPM provision inspections are appropriately trained.
Item No.: 40
Site: Integrated Pest Management-Stores
Violation: The delivery inspection log form only included food and hotel supplies delivered to the ship. There was no record of an inspection for pests on other incoming items delivered to the ship, including floral items and packaged equipment or supplies.
Recommendation: Ensure that incoming shipments of all food and all supplies are routinely inspected for evidence of insects, rodents, and other pests. A record of these inspections shall be maintained onboard the vessel and shall be available for review during inspections.
Item No.: 40
Site: Integrated Pest Management-IPM Plan
Violation: The integrated pest management plan was last evaluated for effectiveness in December 2008.
Recommendation: Ensure that the vessel's Integrated Pest Management Plan is evaluated for effectiveness every 2 years or whenever there is a significant change in the vessel's structure such as a renovation or operation.
Item No.: 08
Site: Potable Water-Cabins
Violation: There was no backflow prevention device installed on the flexible spray hose connection for the showers in the cabins for disabled persons. The hose was long enough to reach the deck.
Recommendation: Ensure that backflow preventers are installed when air gaps are impractical or when water under pressure is required.
Item No.: 41
Site: Children Area-Toy Box Child Toilet Room
Violation: There was no sign posted in this toilet room advising the providers to wash their hands and the children's hands after assisting children using the toilet.
Recommendation: Ensure that signs are posted in children's toilet rooms advising the providers to wash their hands and the children's hands after assisting children using the toilet.
Item No.: 41
Site: Children Area-Tumblers Room
Violation: The night nursery linens were laundered every four days according to staff. Children are assigned the same cot or bed for the entire cruise.
Recommendation: Ensure that surfaces that children touch with their hands are cleaned and disinfected at least daily with products labeled by the manufacturer for that purpose.
Item No.: 08
Site: Potable Water-Tank Records
Violation: On 16 March, 2010 the interior of the potable water tank 11 was spot painted with a Sigma Phenguard 940 paint product. The records indicate some of the details of the procedure and coating, but not all those details or the details of the drying. Additionally, no information could be found to verify that this coating is approved for potable water tank coating according to ANSI/NSF Standard 61 or an equivalent health standard for potable water tanks.
Recommendation: Ensure that interior coatings on potable water tanks are approved for potable water contact, and all manufacturer's recommendations for application, drying, or curing are followed. Ensure written documentation for the coating used and recommendations followed are available for review during inspections.
Item No.: 10
Site: Room Service-Suction Fittings
Violation: The suction covers on the side walls of all four swimming pools did not appear to be a type which meets anti-entrapment or anti-entanglement requirements under ASME/ANSI A112.19.87M or its equivalent. There was no written documentation for these drain covers regarding anti-entrapment approval.
Recommendation: Ensure that anti-entrapment drain covers or other drains that prevent entrapment hazards as specified in U.S. Consumer Product Safety Publication 363-009801 (dual drains/channel drains) are provided on swimming pools and whirlpool spas. Ensure that drain covers have either the plumbing/engineering approving organization stamp and flow rate affixed to the cover, or that a letter is maintained aboard the vessel certifying that the cover meets the safety requirements outlined in AMSE/ANSI A112.19.8M or an equivalent standard.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program