Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Silver Cloud Cruise Line: Silversea Inspection Date: 02/17/2011 Inspection Score: 99
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 20
Site: Galley-Deck 4 - Coffee Pantry
Violation: A slotted fastener was above the milk frother on the left side of the espresso machine.
Recommendation: Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Item No.: 26
Site: Galley-Deck 4 - Coffee Pantry
Violation: A slotted fastener above the milk frother on the left side of the espresso machine was soiled.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 39
Site: Galley-Deck 4
Violation: Two live fruit flies observed along the shelving in the main galley.
Recommendation: Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
Item No.: 37
Site: Galley-Deck 4 - Potwash
Violation: Condensate was collecting on the deckhead immediately above the potwash machine and along the clean landing. No clean items were impacted.
Recommendation: Ensure that ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: 39
Site: Galley-Deck 4 - Bakery / Pastry
Violation: Two live fruit flies observed in the bakery / pastry area that was in operation at the time of the inspection.
Recommendation: Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
Item No.: 27
Site: Galley-Deck 4 - Potwash
Violation: The technical space along the soiled landing of the potwash station was soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Galley-Decks
Violation: In a few locations there were cracked or missing deck tiles, especially along deck/bulkhead junctures. In other areas, especially near the soup station, there was recessed grout.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 38
Site: Galley-Deck 4 - Portable Freezer
Violation: The portable freezer, number MGH/T-1 was out-of-service since 29 November 2010. The staff members indicated they were waiting for a replacement part.
Recommendation: Ensure that only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 27
Site: Galley-Deck 4 - Preparation Line
Violation: The two large support beams and the stainless steel cabinets adjacent to the beams were soiled with dust and food residue.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 34
Site: Galley-Deck 4 - Silver Locker
Violation: A water leak was observed coming from the bulkhead behind the three-compartment sink.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 27
Site: Galley-Deck 6 - Pantry
Violation: The previously cleaned shelf on the back and bottom of the preparation counter was soiled with a sticky substance and dust. This area was closed at the time of the inspection.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 08
Site: Galley-Deck 5 - Main Bar
Violation: The vents of the backflow preventer protecting the hot water supply were painted over.
Recommendation: Ensure that backflow preventers are maintained in good repair.
Item No.: 21
Site: Galley-Deck 4 - Soup Station
Violation: The sealant along the back of the tilting kettles and pans was peeling.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 08
Site: Potable Water-Tank Maintenance Records
Violation: All four potable water tanks were spot painted in April 2010 but the records do not indicate the details of the application, drying, and curing.
Recommendation: Ensure that interior coatings on potable water tanks are approved for potable water contact, and all manufacturer's recommendations for application, drying, or curing are followed. Ensure written documentation for the coating used and recommendations followed are available for review during inspections.
Item No.: 08
Site: Potable Water-
Violation: No records were available documenting that the reduced pressure backflow preventers installed on both evaporators, port and starboard, were ever tested after installation. The staff stated that they preformed the test but did not record the results.
Recommendation: Ensure that backflow prevention devices requiring testing, for example reduced pressure backflow preventer and double check valves with test cocks, are inspected and tested with a test kit at least annually and that the test results showing the pressure differences on both sides of the valves are maintained for each device.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: The reduced pressure backflow preventers installed on both evaporators, port and starboard, were not listed on the cross-connection control program.
Recommendation: Update the cross-connection control program.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: The cross-connection control program does not identify the type of backflow preventers located in the evaporator rooms and in the stabilizer rooms.
Recommendation: Update the cross-connection control program.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: The air gaps located at the saline water drains for the evaporators were not listed on the cross-connection control program.
Recommendation: Update the cross-connection control program.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program