Item No.:
39
|
|
Site:
Integrated Pest Management-Incinerator Room
|
|
Violation:
There were more than seven small black flies near the handwash station. This room was full of garbage and had an odor. In the immediate area, there were three empty sticky tape fly traps hanging from the deckhead and one completely full sticky tape fly trap near the compactor. At the time of the inspection, a crew member installed a new sticky tape fly trap near the handwash station.
|
|
Recommendation:
Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
The cross-connection control program did not include the location for some of the backflow prevention devices. For example, the list indicated two devices for each Crystal Penthouse Suite, but did not specify these devices were installed at the shower hose and the whirlpool tub hose.
|
|
Recommendation:
Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Spa
|
|
Violation:
Passengers could wash their hands in the toilet room and exit to the common area using the tissue paper provided, but there was no waste container.
|
|
Recommendation:
Equip public toilet facilities so that persons exiting the toilet room are not required to handle the door with bare hands. This may be accomplished by methods such as locating paper towel dispensers at sinks and waste containers near the room door, installing mechanically operated doors, door removal, or other effective means.
|
|
|
Item No.:
34
|
|
Site:
Galley-Dishwash Port Side
|
|
Violation:
There was a water leak at the middle faucet of the handwash station. This was corrected.
|
|
Recommendation:
Ensure that a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
34
|
|
Site:
Galley-Hot Galley
|
|
Violation:
There was a water leak at the sink faucet next to the flat grills.
|
|
Recommendation:
Ensure that a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
16
|
|
Site:
Galley-Cold Store #31
|
|
Violation:
There was a tray of beure blanc bechamel with a discard date of 27 February 2011. According to the cooling log, this food item was prepared and blast chilled on the morning of 19 February 2011. This discard date was more than seven calendar days after preparation.
|
|
Recommendation:
Ensure that refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours is clearly marked at the time of preparation to indicate the date or day by which the food shall be consumed, which is 7 calendar days or fewer from the day the food is prepared with the day of preparation counting as day 1. (2) A container of refrigerated, ready-to-eat potentially hazardous food prepared and packaged by a food processing plant and held on the vessel after opening more than 24 hours is clearly marked, at the time the original container is opened, to indicate the date by which the food shall be consumed which is, including the day the original container is opened, 7 calendar days or fewer after the original container is opened. The day of opening is counted as day 1.
|
|
|
Item No.:
20
|
|
Site:
Galley-Pastry
|
|
Violation:
There were slotted fasteners in the food splash zone of the deck ovens.
|
|
Recommendation:
Install low profile, non-slotted, non-corroding, and smooth fasteners.
|
|
|
Item No.:
34
|
|
Site:
Galley-Prego
|
|
Violation:
There was a water leak at the steam table faucet. This was corrected.
|
|
Recommendation:
Ensure that a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Dining Room-Silk Road
|
|
Violation:
There was no coving at the deck/cabinet juncture on the working side of the waiter stations.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
|
|
|
Item No.:
33
|
|
Site:
Provisions-Bonded/Beverage Room
|
|
Violation:
There were a few small holes in the deckhead near the smoke detectors, exposing the insulation. This was corrected.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
|
|
|
Item No.:
20
|
|
Site:
Provisions-Fruit Preparation Room
|
|
Violation:
There were slotted fasteners in the food contact area of the right potato peeler. This equipment was not in use at the time of the inspection.
|
|
Recommendation:
Install low profile, non-slotted, non-corroding, and smooth fasteners.
|
|
|
Item No.:
34
|
|
Site:
Provisions-Butcher Shop
|
|
Violation:
There was a water leak at the three-compartment sink faucet.
|
|
Recommendation:
Ensure that a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
27
|
|
Site:
Provisions-Fish Preparation Room
|
|
Violation:
There was an accumulation of food residue in the large slotted fastener located at the right of the casing of the fish band saw. This equipment was previously cleaned and was not in use at the time of the inspection.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
22
|
|
Site:
Galley-Dishwash
|
|
Violation:
All nozzles from the final sanitizing rinse spray arm had an ineffective spray pattern. This was corrected.
|
|
Recommendation:
Ensure that warewashing equipment is maintained in good repair and proper adjustment including: (1) Being maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; and (2) Maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
|
|
|
Item No.:
33
|
|
Site:
Bar-Ice Cream Bar / Trident Bar
|
|
Violation:
The deckhead above the food preparation areas was constructed of metal in an open grid-like pattern that exposed the ventilation piping, rusted metal components, and coils. The deckhead was soiled with dust.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
30
|
|
Site:
Buffet-Lido - Aft Service Line
|
|
Violation:
There was no "wash hands often" sign posted over the handwash sink.
|
|
Recommendation:
Ensure that a sign stating "WASH HANDS OFTEN" in a language that the food employees understand is posted over handwashing sinks.
|
|
|
Item No.:
33
|
|
Site:
Bar-The Bistro
|
|
Violation:
There was no coving at the deck/counter juncture on the service side of the bar.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
|
|
|
Item No.:
33
|
|
Site:
Dining Room-Prego
|
|
Violation:
There was no coving at the deck/cabinet juncture on the working side of the waiter stations.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
|
|