Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Zaandam Cruise Line: Holland America Line Inspection Date: 02/06/2011 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Potable Water-Potable Water Bunkering Records / Pre-chlorination
Violation: The free halogen residual charts dating from 14 September 2010 to 23 October 2010 had recordings of free halogen residual levels continuously changing from 0 ppm to 5 ppm during the bunkering process. According to the staff and email correspondence, these dates matched the time that a new monitoring system was installed and it was hard to stabilize. No manual recordings were conducted. The malfunctioning device was corrected.
Recommendation: Ensure that a halogen residual and pH test is conducted on the shore-side water supply before starting the bunkering process to establish the correct halogen dosage. Record the results of this pretest and have available for review during inspections.
Item No.: 08
Site: Potable Water-Bunker Stataion / Starboard
Violation: The top potable water connection was facing upwards.
Recommendation: Ensure that the potable water bunker filling line begins either horizontally or in a gooseneck position pointing downwards, at a point at least 45 cm (18 inches) above the bunker station deck.
Item No.: 08
Site: Potable Water-
Violation: The annual test of all 16 testable backflow prevention devices were past due, with due dates dating as far back as August 2010. According to documentation in AMOS, a new test kit was identified on 5 February 2011 to initiate a purchase order.
Recommendation: Ensure that backflow prevention devices requiring testing, for example reduced pressure backflow preventer and double check valves with test cocks, are inspected and tested with a test kit at least annually and that the test results showing the pressure differences on both sides of the valves are maintained for each device.
Item No.: 16
Site: Galley-
Violation: Two unopened bags of cut raw spinach were inside the undercounter reach-in refrigerator with a food temperature of 47°F. They were removed and iced down immediately.
Recommendation: Ensure that cut leafy greens are maintained at temperatures of 41ºF (5ºC) or less during cold storage and display.
Item No.: 20
Site: Preparation Room-Provisions
Violation: The potato peeler was posted out of order on 31 July 2010 and staff stated that they were still awaiting the spare parts needed to repair this machine.
Recommendation: Repair or replace this potato peeler.
Item No.: 20
Site: Buffet-Starboard Ice Cream Parlor
Violation: The soft serve ice cream machine was posted out of order from 8 May 2010. Staff stated they are waiting on spare parts.
Recommendation: Repair or replace this soft serve ice cream machine.
Item No.: 21
Site: Buffet-Beverage Station
Violation: The underside upper stainless steel panel for the ice and water dispenser had large gaps around the dispensing chutes for both ice and water.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 22
Site: Galley-Dishwash
Violation: The in-use #1 dishwashing machine displayed a rinse tank temperature of 163°F, while the manual temperature of the rinse water was measured at 154-155°F on both the inspector's thermometer and that of the staff.
Recommendation: Ensure that water temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit are designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit are designed to be accurate to ±3°F in the intended range of use.
Item No.: 26
Site: Galley-Dishwash
Violation: The two large in-use ice machines had an accumulation of a small white and gray colored granular material in the interior water bath surfaces.
Recommendation: Ensure that food only contacts surfaces of equipment and utensils are cleaned and sanitized.
Item No.: 33
Site: Food Service General-Main Galley, Pinnacle Grill and Crew Galley
Violation: The deck surface was pitted in various areas, making cleaning difficult. The new deck prototype was installed in other galley areas and appeared to be in good condition. The staff provided details on the plan to install the new epoxy deck system in the remaining areas of the galleys. Some of these areas were noted in the previous VSP inspection report.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Bar-Explorations Cafe
Violation: There was dust on the decorative deckhead over this coffee bar.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Other-Terrace Grill
Violation: Dust was accumulating and hanging from the open style deckhead above the buffet counter.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 34
Site: Galley-Dishwash
Violation: The area was not in use at the time, but water was leaking from the deckhead onto a small deck stand positioned immediately beside the clean dish landing table for the conveyor dishwashing machine.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 39
Site: Buffet-Lido Juice Station
Violation: Four small black live flies were on the deckhead over and the bulkhead behind the juice dispensers and the fresh orange juice machine. This buffet station was not in service at the time of the inspection, but the clean equipment was present and subject to contamination.
Recommendation: Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
Item No.: 39
Site: Buffet-Starboard Ice Cream Parlor
Violation: There were three small black live flies circulating at the bulkhead behind the chest ice cream freezer and the clean stacked bowls on the counter immediately beside the bulkhead. This area was not in service at the time of the inspection.
Recommendation: Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
Item No.: 39
Site: Galley-Potwash
Violation: There were 12 small black live flies on the deckhead over the clean pot racks and one small black live fly on the bulkhead at the entry door to the potwash. Staff members were cleaning soiled pots at the time and the clean racks were filled with clean pots and utensils.
Recommendation: Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program