Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Seven Seas Navigator Cruise Line: Regent Seven Seas Inspection Date: 02/03/2011 Inspection Score: 94
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 10
Site: DO NOT USE (whirlpool/spa)-
Violation: During the period of 14 June 2010 to 15 September 2010 (about four months), the pH levels recorded manually from the port and starboard whirlpool spas ranged from 6.4 to 7.0 most of the times. In addition, the pH levels were not recorded since 29 December 2010 when chart recordings were implemented. According to the staff, pH levels were monitored but not recorded.
Recommendation: Ensure that the whirlpool spa water is maintained with a pH between 7.2 and 7.8.
Item No.: 08
Site: Potable Water-Garbage Room
Violation: The backflow preventer installed on the handwash station was not identified in the cross-connection control program.
Recommendation: Update the cross-connection control program.
Item No.: 08
Site: Potable Water-Garbage Room
Violation: The cross-connection control program listed an air gap at a handwash station located in the garbage cold room. There was no handwash station in that room.
Recommendation: Update the cross-connection control program.
Item No.: 08
Site: Potable Water-Forward Crew Lauderette
Violation: The backflow preventers installed on the two washing machines were Watts 9D, two for each machine. Only one for each washing machine was identified in the cross-connection control program and they were identified as being Type 90 PN 10.
Recommendation: Update the cross-connection control program.
Item No.: 08
Site: Potable Water-Aft Crew Lauderette
Violation: The backflow preventers installed on the two washing machines were Watts 9D but they were identified in the cross-connection control program as being Type 90 PN 10. In addition, one non-continuous pressure backflow preventer was listed as being installed at the soap dispenser; however, there was no backflow preventer installed.
Recommendation: Update the cross-connection control program.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: The cross-connection control program did not always identify the type of the installed backflow preventer. In many instances, these devices were identified as "two for this sink", "1 each machine", etc. It was difficult to identify these backflow prevention devices and verify the accurateness of the plan.
Recommendation: Update the cross-connection control program.
Item No.: 08
Site: Potable Water-Bridge Pantry
Violation: The backflow preventer installed on the handwash station was not identified in the cross-connection control program.
Recommendation: Update the cross-connection control program.
Item No.: 08
Site: Potable Water-Spa
Violation: The two backflow preventers installed on the left hair wash station were not identified in the cross-connection control program.
Recommendation: Update the cross-connection control program.
Item No.: 08
Site: Potable Water-Spa
Violation: The backflow preventer installed on the cold water supply line of the right hair wash station was not identified in the cross-connection control program. In addition, there was no backflow preventer installed on the hot water supply line. The flexible water hose connected to the hair wash nozzle was long enough to reach the sink.
Recommendation: Ensure that backflow preventers are installed when air gaps are impractical or when water under pressure is required. Update the cross-connection control program.
Item No.: 08
Site: Potable Water-Spa
Violation: The backflow preventers installed on the foot bath station were not identified in the cross-connection control program.
Recommendation: Update the cross-connection control program.
Item No.: 08
Site: Potable Water-Spa
Violation: There were no backflow preventers installed on the flexible shower hoses located in room #5 and room #6. The hoses were long enough to reach the deck.
Recommendation: Ensure that backflow preventers are installed when air gaps are impractical or when water under pressure is required.
Item No.: 08
Site: Potable Water-Tank Maintenance Records
Violation: The potable water tanks maintenance records indicated some of the details of the procedure of spot painting, but the details of the drying and curing were not recorded and there was no statement that the paint had been applied, dried and cured according to the manufacturer's recommendations.
Recommendation: Ensure that interior coatings on potable water tanks are approved for potable water contact, and all manufacturer's recommendations for application, drying, or curing are followed. Ensure written documentation for the coating used and recommendations followed are available for review during inspections.
Item No.: 41
Site: Ventilation-Condensate Drain Pans
Violation: The condensate collection pans for units AC-102 and AC-302 were not accessible for inspection, maintenance, and cleaning. There was no sight glass or other effective method available for full inspection and cleaning. Per staff, there were other air handling units with these same designs.
Recommendation: Ensure that air handling unit condensate drain pans and collection systems are accessible for inspection, maintenance, and cleaning.
Item No.: 19
Site: Buffet-La Veranda
Violation: There was no serving utensil for the bowl of fruit on the starboard buffet line. There were apples, grapes, and plums in the bowl.
Recommendation: Ensure that food-dispensing utensils are available for each container displayed at a consumer self-service unit such as a buffet or salad bar.
Item No.: 27
Site: Buffet-La Veranda
Violation: The undercounter technical compartments 104403A and 104402A on the starboard buffet line were soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Buffet-La Veranda
Violation: The undercounter technical compartment 003235 on the port hot line was soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Buffet-La Veranda Grill
Violation: The gas barbecue grill was soiled on the front panel, the bottom panel, and under the front edge. This area was previously cleaned.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Buffet-La Veranda Grill
Violation: Four gas tanks were stored on the deck below the gas barbecue grill. The rubber deck mat below the tanks was soiled.
Recommendation: Ensure that the tanks are stored at least six inches above the deck to facilitate proper cleaning. Ensure that the deck is clean.
Item No.: 39
Site: Galley-La Veranda
Violation: There were many small, light-colored, non-flying insects on the bottom of the technical compartment below the utility sink. The compartment was heavily soiled on the bottom and sides. The area was immediately sprayed with pesticide and, according to the staff, was going to be thoroughly cleaned.
Recommendation: Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
Item No.: 27
Site: Galley-La Veranda
Violation: The technical compartment below the utility sink was heavily soiled on the bottom and sides.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Buffet-La Veranda Grill
Violation: There was a seam where the flat grill met the counter. A job order had already been submitted.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Buffet-La Veranda Grill
Violation: The seam where the flat grill met the counter was soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 18
Site: Pantry-La Veranda
Violation: Raw ground meat in the form of mini burgers were stored directly above a plastic bin of raw shell eggs.
Recommendation: Ensure that food is protected from cross-contamination by: (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry during storage, preparation, holding, and display by using separate equipment for each type, or arranging each type of food in equipment so that cross-contamination of one type with another is prevented, and preparing each type of food at different times or in separate areas.
Item No.: 33
Site: Galley-La Veranda
Violation: The food lift door track was soiled.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 27
Site: Galley-La Veranda
Violation: The bottom panel on the boiler was soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Galley-La Veranda
Violation: The bottom panel on the boiler was loose.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Galley-La Veranda
Violation: There was a hole in the bulkhead above the newly installed stand-alone compressor unit.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 37
Site: Galley-La Veranda
Violation: There was a leak from the condensate lines above the newly installed stand-alone compressor unit.
Recommendation: Ensure that the condensate lines do not leak.
Item No.: 34
Site: Galley-Hot Galley
Violation: There was a leak from the faucet on the right tilting pan in the soup and sauce station. This was corrected.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 27
Site: Galley-Hot Galley
Violation: The bottom and sides of the undercounter technical compartment 002960 were soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-Hot Galley
Violation: The drain nozzle on the right deep fat fryer was soiled with old grease.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 16
Site: Galley-Cold Pantry
Violation: The two upright reach-in refrigerators were labeled as time control. These units were used for room service, which operates 24 hours per day. The time control plan stated that food in the unit would be discarded every four hours and that the food would be labeled. There were no 4-hour discard labels on the food in the refrigerators. According to the staff, they always discard the food at the same 4-hour intervals.
Recommendation: If time only, rather than time in conjunction with temperature, is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure that (1) The food is marked or otherwise identified to indicate the time that is 4 hours past the point in time when the food is removed from temperature control; (2) The food is cooked and served, served if ready-to-eat, or discarded, within 4 hours from the time when the food is removed from temperature control; and (3) The food in unmarked containers or packages or marked to exceed a 4 hour limit is discarded. Ensure that the procedures match the time control plan.
Item No.: 30
Site: Galley-Toilet Room
Violation: There was no sign advising users to wash hands after using the toilet.
Recommendation: Ensure that signs are conspicuously posted on the bulkhead adjacent to the door of the toilet, reading "WASH HANDS AFTER USING TOILET " in a language that the food employees understand.
Item No.: 39
Site: Galley-Cold Preparation
Violation: There were three live nymph roaches on the deck below the utility sink. The roaches appeared to be dying. The area was immediately closed and sprayed with pesticide and two bait stations were added. There was no active preparation in this area at the time of the inspection.
Recommendation: Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
Item No.: 33
Site: Galley-Cold Preparation
Violation: There were two bulkhead penetrations on the left side of the technical compartment below the utility sink.
Recommendation: Close the bulkhead penetrations.
Item No.: 34
Site: Galley-Cold Preparation
Violation: There was water dripping from the bottom of the left undercounter refrigerator.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 27
Site: Galley-Hot Galley
Violation: The bottom of the flat grill was heavily soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Galley-Hot Galley
Violation: The panel on the bottom of the flat grill was not secured properly.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-Hot Galley
Violation: There was a gap at the front of the profile piece on the right edge of the flat grill.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Galley-Hot Galley
Violation: The inside of the profile piece on the right edge of the flat grill was soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 16
Site: Preparation Room-
Violation: The temperatures of a raw boneless chicken breast and raw sliced chicken placed in a pan were measured at 58°F. The 7-day discard label on the pan indicated a preparation date of 2 February. According to the staff, the chicken was prepared on 2 February at 21:30. The temperature was measured at approximately 10:30 on 3 February. The chicken was discarded immediately.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
Item No.: 37
Site: Provisions-Fruit Walk-In Refrigerator
Violation: There was condensate around the edges of the forward deckhead access panel.
Recommendation: Ensure that condensate does not collect on the deckhead.
Item No.: 33
Site: Provisions-Fruit Walk-In Refrigerator
Violation: The edges of the forward deckhead access panel were soiled where the condensate was collecting.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 19
Site: Provisions-Fruit Walk-In Refrigerator
Violation: Condensate was dripping from the edges of the forward deckhead access panel onto boxes of whole melon. The boxes of melon were moved.
Recommendation: Ensure that the condensate does not drip onto food.
Item No.: 33
Site: Bar-Navigator
Violation: The deck below the back bar cabinet was rough and difficult to clean. There was also no coving where the deck below the cabinet met the bulkhead. This area was soiled.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning. Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters). Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program