Item No.:
01
|
|
Site:
Medical-Gastrointestinal Illness Reporting
|
|
Violation:
For 3 of the last 5 cruises, the number of cases of gastrointestinal illness was incorrectly reported.
1/6/11 - 1/16/11 - 3 cases reported but 4 cases were on the gastrointestinal illness log and all cases reported to medical before the 24-hr report was submitted.
1/23/11 - 1/30/11 - 3 cases reported but 4 cases were on the gastrointestinal illness log and all cases reported to medical before the 24-hr report was submitted.
1/30/11-2/6/11 - An additional case reported to medical after the 24 hour report, but more than 4 hours before entering a US port and no 4-hr report was submitted.
|
|
Recommendation:
Provide a system in Medical to ensure that the correct number of gastrointestinal illness cases are reported.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cabins with Whirlpool Tubs
|
|
Violation:
In the cabins with whirlpool tubs, there were two shower hoses with backflow prevention devices installed. Some of these hoses had ORAS vacuum breakers installed. It was unclear if all of the additional shower hoses were included in the cross-connection control program, but the program listed all shower hoses as having Watts S-8 devices.
|
|
Recommendation:
Update the cross-connection control program to include the correct backflow devices installed for the cabins with whirlpool tubs.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Penthouse Cabins
|
|
Violation:
The penthouse cabins had a whirlpool tub on the balcony. Correct backflow prevention devices were installed on the potable water lines to the spray hoses, but they was not included on the cross-connection control program.
|
|
Recommendation:
Update the cross-connection control program to include the devices installed for the penthouse balcony whirlpools.
|
|
|
Item No.:
08
|
|
Site:
Food Service General-Multi-Flow Systems
|
|
Violation:
There was no backflow prevention devices installed on the non-carbonated potable water lines to the dispenser hoses.
|
|
Recommendation:
Install a continuous-pressure backflow prevention device on the potable water line to the dispenser hose or disconnect the potable water line.
|
|
|
Item No.:
11
|
|
Site:
Medical-Close Contacts
|
|
Violation:
During the 2/6/11 - 2/16/11 cruise, there were two reportable gastrointestinal cases in the crew where the close contacts (cabin mates) were not monitored for 48 hours. The cabin mates were initially evaluated and isolated for 24 hours, but not checked again at 48 hours.
|
|
Recommendation:
Ensure that medical staff conduct daily verbal interviews with asymptomatic crew until 48 hours after onset of the ill crew members symptoms.
|
|
|
Item No.:
16
|
|
Site:
Galley-Deck 9 - Asian Counter Preparation - Beverage Station
|
|
Violation:
The temperature of the bulk milk measured 45F. The milk was placed in the bulk milk machine on 15 February 2011. The ambient temperature of the bulk milk machine was 38F. The milk was discarded.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60C (140F) [roasts 54C (130F)] or above, or (2) At 5C (41F) or less.
|
|
|
Item No.:
20
|
|
Site:
Galley-Deck 2 - Salad Station
|
|
Violation:
There were slotted fasteners inside the salad washing machine.
|
|
Recommendation:
Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
|
|
|
Item No.:
20
|
|
Site:
Preparation Room-Deck A - Salad Washer
|
|
Violation:
There were slotted fasteners inside the salad washing machine.
|
|
Recommendation:
Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
|
|
|
Item No.:
20
|
|
Site:
Bar-Deck 3 - Explorations Bar
|
|
Violation:
The open technical space above the hot water dispensing line was corroded.
|
|
Recommendation:
Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
|
|
|
Item No.:
21
|
|
Site:
Galley-Deck 3 - Warewash
|
|
Violation:
There were three plate trolleys that had difficult to clean gouges along the plate contact surfaces.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
26
|
|
Site:
Galley-Deck 3 - Beverage Station
|
|
Violation:
The nozzles were soiled on the two beverage dispensing units.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch. Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
26
|
|
Site:
Buffet-Deck 9 - Taco Station
|
|
Violation:
The chute of the combination ice/water machine was heavily soiled with scale.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch. Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
36
|
|
Site:
Bar-Deck 3 - Explorations Bar
|
|
Violation:
The fluorescent light for the reach-in refrigerator display case was not shielded.
|
|
Recommendation:
Ensure that light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
|
|