Cruise Ship: Seadream I Cruise Line: Sea Dream Yacht Club Inspection Date: 03/06/2011 Inspection Score: 87
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 41
Site: Other-Public Toilets
Violation: The outbreak prevention and response plan (OPRP) section 1.5 states that toilet rooms, including the hand-contact surfaces should be wiped down with disposable towel and chlorine every hour during gastrointestinal illness outbreaks.
Recommendation: Ensure that when the cumulative proportion of cases of gastrointestinal illness among passengers or crew members is 2%, the infection control response includes cleaning and disinfecting all public areas, including handrails and restrooms, on a continuous basis until the proportion decreases to < 2%.
Item No.: 26
Site: Pantry-Deck Pantries 3 and 4
Violation: The in-use ice machines in both pantries had a small accumulation of fine black particles in the water bath below the upper ice cuber panel. Additionally, the cuber top, sides and lower sections were soiled with what appeared to be iron deposits. They wiped away easily with a wet paper towel.
Recommendation: Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 21
Site: Pantry-Deck Pantry #3
Violation: There was insufficient space between the back of the deck mounted warewash machine and the bulkhead to effectively clean. The bulkhead behind the machine was soiled with accumulated dirt debris.
Recommendation: Ensure that equipment that is fixed because it is not easily movable is installed so that it is: (1) Spaced to allow access for cleaning along the sides, behind, under and above the equipment; (2) Spaced from adjoining equipment, bulkhead, and deckhead at a distance of not more than 0.8 millimeter or 1/32 inch; or (3) Sealed to adjoining equipment or bulkhead, if the equipment is exposed to spillage or seepage.
Item No.: 33
Site: Pantry-Deck Pantry #3
Violation: There was insufficient space between the back of the deck mounted warewash machine and the bulkhead to effectively clean. The bulkhead behind the machine was soiled with accumulated dirt debris.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 06
Site: Potable Water-Microbiological Testing
Violation: The random sampling of the potable water distribution system to analyze for the presence of Escherichia coli bacteria involved the same locations for the months October thru January.
Recommendation: Ensure that a minimum of four potable water samples per month are collected and analyzed for the presence of Escherichia coli and are collected randomly from locations on the forward, aft, upper, and lower decks of the vessel. Ensure that sample sites are changed each month.
Item No.: 08
Site: Potable Water-Cross-Connection Program
Violation: Numerous problems exist with the record of backflow preventers onboard. The list of preventers includes devices for all passenger cabin flexible shower hoses where no backflow preventers are installed. The list indicates testing for nearly all the preventers which cannot be tested. Cabin toilets are listed as 288A devices and showers as ORAS model, when showers are only fitted with non-return valves and toilets are fitted with ORAS model preventers. It was unclear from the list if the various engine room compartments have been checked since the last date given in December 2005. In crew lavatories, some flexible showers were protected while others were not, and all were listed as ORAS preventers, but they were not. Lastly, there are air-gaps listed where the comment under checked date is non needed. The boiler feed filling air-gap is one which does require routine inspection.
Recommendation: The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems. Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing.
Item No.: 05
Site: Potable Water-Far Point Calibration
Violation: A manual test was made at the far point of the potable water distribution system to verify the free chlorine residual and the accuracy of the halogen analyer. The analyzer and chart registered 3.2 ppm (mg/L) while the inspector's kit registered 2.28 ppm. The ship's kit registered 2.4 ppm when the analyzer displayed 3.13 ppm. The analyzer was calibrated again following the test.
Recommendation: Ensure that the free residual halogen measured by the halogen analyzer is ±0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
Item No.: 09
Site: DO NOT USE (whirlpool/spa)-Spa
Violation: The analyzer/recorder charts indicating the bromine residual during operation of the whirlpool spa indicated the residual was below the minimum 4 ppm since the analyzer/recorder charts were installed in December 2010. Staff stated that manual measures were made throughout the day by security staff posted near the pool and whirlpool spa, but that staff indicated they do not maintain records of those tests.
Recommendation: Ensure that whirlpool spas are maintained at a free residual chlorine of >3.0 mg/L (ppm) and <10 mg/L (ppm), or a free residual bromine of >4.0 mg/L (ppm) and <10 mg/L (ppm).
Item No.: 10
Site: DO NOT USE (whirlpool/spa)-Spa
Violation: No record of shock halogenation was made onboard, so staff were questioned about the process of closing the whirlpool spa and cleaning prior to refilling. Staff did not raise the free halogen level to 10 ppm and circulate for one hour prior to draining.
Recommendation: Ensure that the free residual halogen is increased to at least 10.0 mg/L (ppm) in whirlpool spas and circulated for at least 1 hour at the end of each day.
Item No.: 10
Site: Recreational Water Facilities-Pool and Whirlpool Spa
Violation: The ship did not have a written fecal accident response procedure for either the swimming pool or whirlpool spa.
Recommendation: Ensure that a fecal accident response procedure, which meets or exceeds the procedure provided in annex 13.11, is documented and available to the VSP for review during inspections. Ensure that a written or electronic record of all fecal accidents is maintained. Ensure that the record includes the pool name, date and time of the incidnet, response steps taken, free residual halogen level achieved following cleaning, and contact times.
Item No.: 10
Site: DO NOT USE (whirlpool/spa)-Pool and Whirlpool Spa
Violation: There were no records made of the calibration each day for the swimming pool or whirlpool spa bromine analyzer/recorders, and there was no manual test records to verify the values on any of these charts since they were installed in December of 2010.
Recommendation: Ensure that halogen analyzer-chart recorders used in lieu of manual tests and logs are calibrated daily, and that the calibration is recorded on the chart or in a log book.
Item No.: 34
Site: Buffet-Cold Pantry #5
Violation: There was a water leak at the faucet of this handwash station.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 33
Site: Galley-Hot Galley Deck 5
Violation: The fire detector located on the deckhead over the grill was soiled.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 21
Site: Galley-Hot Galley Deck 5
Violation: The cables of the combination oven were draped on the countertop making cleaning difficult. The countertop was soiled around the cables.
Recommendation: Ensure that cables are shortened or secured above the counters.
Item No.: 27
Site: Galley-Hot Galley Deck 5
Violation: The cables of the combination oven were draped on the countertop making cleaning difficult. The countertop was soiled around the cables.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Pantry-Dishwash Area - Pantry #5
Violation: The exhaust covers located over the door type dishwasher were soiled.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 24
Site: Pantry-Lido Dishwash - Pantry #5
Violation: The final rinse temperature of the hood type dishwasher was measured at 151°F. The manufacturer's data plate recommended a final rinse temperature of 180°F. This unit was in use at the time of the inspection.
Recommendation: In a mechanical operation, ensure that the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F), or less than: (1) For a stationary rack, single temperature machine, 74°C (165°F); or (2) For all other machines, 82°C (180°F); or (3) A utensil surface temperature of 71°C (160°F) as measured by an irreversible registering temperature indicator shall be achieved. (4) The maximum temperature of 90°C (194°F), does not apply to the high pressure and temperature systems with wand-type, hand-held, spraying devices used for the in-place cleaning and sanitizing of equipment such as meat saws.
Item No.: 26
Site: Galley-Ice Machine
Violation: There was rusted metal and rust dust on the door hinge and the inside of the door on the ice bin. Also the cubing area was soiled with a rusty colored substance.
Recommendation: Ensure that ice and water contact surfaces are clean.
Item No.: 28
Site: Galley-Dishwash Area
Violation: There were a number of already cleaned metal containers stacked together that were still wet.
Recommendation: After cleaning and sanitizing, ensure that equipment and utensils are air-dried or adequately drained before contact with food.
Item No.: 20
Site: Galley-Pastry/Bakery Area
Violation: There was one slotted fastener and two gaps suggesting missing fasteners in the inside of the deck oven.
Recommendation: Install the missing fasteners and remove the slotted fasteners and replace with smooth, low-profile, non-slotted fasteners.
Item No.: 33
Site: Galley-Pastry/Bakery Area
Violation: The hinges of the deckhead hatch were soiled.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 16
Site: Buffet-
Violation: There was a hotel pan with fish pieces in a creamy sauce inside the hot holding unit located under the bain marie. This unit was on time control. According to the time control plan, the discard time for the food service for breakfast was at 09:00. However, this hotel pan was still in the hot holding unit at 10:05. This food item was discarded.
Recommendation: Ensure that the time control plan is followed by discarding potentially hazardous foods after four hours of being placed on time control.
Item No.: 26
Site: Pantry-Ice Macine
Violation: There was rusted metal and rust dust on the door hinge and the inside of the door to the ice bin. Also the cubing area was soiled with a rusty colored substance.
Recommendation: Ensure that ice and water contact surfaces are clean.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program