Cruise Ship: Seven Seas Navigator Cruise Line: Regent Seven Seas Inspection Date: 07/27/2011 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Potable Water-Storage Tank
Violation: The sample valve and collection point on potable water tank FW3P were turned horizontal.
Recommendation: Ensure that potable water tanks have sample valves which are turned down.
Item No.: 08
Site: Potable Water-Production
Violation: On 2 July 2011 production was started at 9:15 AM and a free halogen residual test was not taken until between 11:00 AM and Noon. On 9 July 2011 production was started at 8:45 AM but a free halogen residual test was not taken until between 11:00 AM and Noon.
Recommendation: Ensure that free residual halogen monitoring is performed at least hourly during the bunkering of potable water and performed at least once every 4 hours during the onboard production of potable water. When starting production, potable water must reach 2 ppm within 30 minutes. Until 2 ppm is reached, conduct free halogen residual tests every 5-10 minutes.
Item No.: 08
Site: Potable Water-Production
Violation: On 4 July 2011 a free residual halogen test was conducted at 7:00 AM during production but no other test was conducted before production was stopped at Noon.
Recommendation: Ensure that free residual halogen monitoring is performed at least hourly during the bunkering of potable water and performed at least once every 4 hours during the onboard production of potable water.
Item No.: 06
Site: Potable Water-Far Point
Violation: On several days since the last USPHS inspection, neither the manual comparison test nor the calibration was documented daily.
Recommendation: Ensure that the daily, manual comparison test or calibration is recorded on the chart or in a log book.
Item No.: 33
Site: Other-Deck 11 Linen Closet/Butler Office
Violation: Several stored food items, including wine and beer bottles, soda cans, and opened crackers were being stored in this area. Soiled carpet was on the deck and exposed insulation was on the bulkhead and deckhead.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning. Ensure that bulkheads and deckheads have smooth, hard finishes, and light colored surfaces.
Item No.: 22
Site: Other-Deck 11 Linen Closet/Butler Office
Violation: Multiple trays of soiled dishes and utensils containing food remnants were stored on the computer desk. Several soiled bowls were stored on the desk chair.
Recommendation: Ensure that drainboards, utensil racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing. Soiled dishes and utensils should be stored in the appropriate warewashing area of the vessel.
Item No.: 19
Site: Other-Deck 11 Linen Closet/Butler Office
Violation: Several cardboard boxes of beer and wine were stored on the deck.
Recommendation: Ensure that food is protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 20
Site: Galley-Vegetable Preparation - Slicer
Violation: Numerous small cracks were present in the plastic press plate of the slicer.
Recommendation: Ensure that food contact surfaces of equipment and utensils are designed and constructed to be durable and to retain their characteristic qualities under normal use conditions.
Item No.: 20
Site: Buffet-Officer's Mess - Beverage Station
Violation: The protective covering for the combination ice/water machine technical compartment at the ice chute and water dispensing nozzle was missing.
Recommendation: Replace the protective covering for the technical compartment.
Item No.: 26
Site: Buffet-Officer's Mess - Beverage Station
Violation: A light accumulation of a red substance and scale soiled the ice chute, water dispensing nozzle, and surrounding area of the combination ice/water machine technical compartment.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 20
Site: Buffet-Crew Mess - Beverage Station
Violation: The protective covering for the combination ice/water machine technical compartment at the ice chute and water dispensing nozzle was missing.
Recommendation: Replace the protective covering for the technical compartment.
Item No.: 08
Site: Galley-Warewash
Violation: Water was leaking in a continuous stream from the Atmospheric Vacuum Breaker (AVB) from the final rinse nozzles on the back of the flight-type warewash machine.
Recommendation: Ensure that backflow preventers are maintained in good repair.
Item No.: 22
Site: Galley-Warewash
Violation: Heavy scale deposits soiled the inside of the flight-type warewash machine just after the hot air blower duct and the final rinse nozzle. In addition, an accumulation of dust soiled the top of the blower duct.
Recommendation: Ensure that warewashing machines; the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw foods, or laundering wiping cloths; and drainboards are cleaned: (1) Before use; (2) Throughout the day at a frequency necessary to prevent recontamination of equipment and utensils and to ensure that the equipment performs its intended function; and (3) If used, at least every 24 hours.
Item No.: 34
Site: Galley-Pastry Station
Violation: The drain line for the ice cream dipper well was obstructed.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 16
Site: Galley-Pastry Station - Walk-in Refrigerator
Violation: A metal pan of vanilla pastry cream with a production date of 26 July 2011 covered by plastic wrap had an internal temperature that ranged from 48°F to 54°F when measured by the inspector's thermocouple. This item was discarded.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
Item No.: 16
Site: Galley-Garde Manger - Walk-in Refrigerator
Violation: A large plastic pan of shredded cabbage with a production date of 26 July 2011 had an internal temperature that ranged from 44°F to 46°F when measured by the inspector's thermocouple. This item was discarded.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
Item No.: 20
Site: Galley-Room Service/Wine Cellar
Violation: A crack was observed along the side of the horizontally mounted guard/manifold of the single cuber tray type ice machine, which made cleaning difficult.
Recommendation: Ensure that food contact equipment is maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
Item No.: 26
Site: Galley-Room Service/Wine Cellar
Violation: A red substance soiled the crack of the single cuber type ice machine and the face of the plastic manifold and the leading edge, closest to the ice chute. In addition, a red substance soiled the face of the plastic manifold and leading edge of the double cuber type ice machine.
Recommendation: Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 20
Site: Buffet-24-hour Coffee Station Near Pool
Violation: The decorative metal plating on the dispensing nozzles of the espresso machine was damaged and was flaking off, which made cleaning difficult.
Recommendation: Ensure that food contact equipment is maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
Item No.: 22
Site: Food Service General-Hood Type Warewash Machines
Violation: An accumulation of scale and other debris soiled areas near the exhaust vent along the back of the machines and along the piping leading to the upper manifolds. Some of the upper and lower manifolds were also soiled.
Recommendation: Ensure that warewashing machines; the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw foods, or laundering wiping cloths; and drainboards are cleaned: (1) Before use; (2) Throughout the day at a frequency necessary to prevent recontamination of equipment and utensils and to ensure that the equipment performs its intended function; and (3) If used, at least every 24 hours.
Item No.: 21
Site: Food Service General-Sealant
Violation: Excessive sealant was found along many seams and gaps of non-food contact surfaces of equipment such as ice machines and tilting pans, which made cleaning difficult.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Galley-Hot Galley - Tilting Pans
Violation: Excessive sealant was found along the deckhead support beams, which made cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 28
Site: Other-Deck 11 Linen Closet/Butler Office
Violation: A tray containing soiled linen napkins was stored on top of cardboard boxes.
Recommendation: Ensure that soiled linens are kept in clean, nonabsorbent receptacles or clean, washable laundry bags and stored and transported to prevent contamination of food, clean equipment, clean utensils, and single-service and single-use articles.