Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Seabourn Sojourn Cruise Line: Seabourn Cruise Line Inspection Date: 09/28/2011 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 20
Site: Galley-Colonnade
Violation: Four cutting boards, one each in the fish station, grill station, bread cutting station and hot line were heavily scored.
Recommendation: Ensure that surfaces such as cutting blocks and boards that are subject to scratching and scoring are resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
Item No.: 29
Site: Buffet-Colonnade
Violation: A warming unit was blocking access to the handwashing station adjacent to the starboard side of the hot buffet line. This area was in active operation at the time of the inspection. The warming unit was removed.
Recommendation: Ensure that handwashing facilities are used for no other purpose and are accessible at all times.
Item No.: 24
Site: Buffet-Colonnade
Violation: The concentration of chlorine sanitizing solution in a bucket behind the cold buffet line was less than 50 mg/L. The solution was replaced.
Recommendation: Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item No.: 24
Site: Galley-Colonnade
Violation: The concentration of chlorine sanitizing solution in a bucket in the fish prep area was less than 50 mg/L. The solution was replaced.
Recommendation: Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item No.: 19
Site: Buffet-Colonnade
Violation: The food contact area of two pairs of tongs were not protected under the bread station sneeze guard. The tongs were placed under the sneeze guard.
Recommendation: Ensure that each self-service food dispensing utensil is covered or located beneath shielding during service.
Item No.: 26
Site: Galley-Port Side Warewashing
Violation: Several previously cleaned escargot dishes were soiled and stored on the clean warewashing rack.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 28
Site: Dining Room-Wine Pantry Port Side
Violation: Three clean wine carafes were stored adjacent to several menus and a stack of paperwork on the same shelf. The wine carafes were moved to a separate, clean shelf.
Recommendation: Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (2) Where they are not exposed to splash, dust, or other contamination.
Item No.: 28
Site: Galley-Port Side Dining Room Pantry
Violation: There was a previously cleaned ice crusher stored on top of several pieces of paperwork in an overhead cabinet. This was corrected.
Recommendation: Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (2) Where they are not exposed to splash, dust, or other contamination.
Item No.: 28
Site: Galley-Port Side Beverage Station
Violation: Several pieces of clean equipment such as utensils, pots, and pans were stored in a small utensil locker that was soiled with crumbs, dust, and food debris.
Recommendation: Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination.
Item No.: 36
Site: Dining Room-Main Waiter Stations
Violation: The maximum light intensity in several areas of waiter stations #1 port and #1 starboard side was less than 220 Lux.
Recommendation: Ensure that the light intensity is at least 220 Lux (20 foot candles) in bars and at dining room waiter stations during periods of cleaning.
Item No.: 28
Site: Galley-Port Side Utensils Locker
Violation: Clean equipment was stored in the large utensil locker behind the beverage station with cardboard boxes and several pieces of paperwork.
Recommendation: Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (2) Where they are not exposed to splash, dust, or other contamination.
Item No.: 39
Site: Galley-Cold Galley
Violation: One small fly was over a plate of cooked vegetables.
Recommendation: Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: There were several backflow prevention devices on the non-testable list for 'technical rooms' and 'public rooms' where the plumbing component was not included. Also, the backflow prevention method for the evaporators was listed as 'NA', but there was an air gap at the evaporators.
Recommendation: Ensure that the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: The backflow prevention devices for the spray hoses on the balcony whirlpool and the jetted bathtub could not be located. It was also unclear on the cross-connection control program which devices corresponded to these spray hoses.
Recommendation: The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities. Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing. Ensure that backflow preventers are located so they may be inspected, serviced, and maintained.
Item No.: 06
Site: Potable Water-Production Charts
Violation: On 19 September 2011 and 26 September 2011, there was more than 2 hours between the start of production and the first recorded calibration check of the analyzer.
Recommendation: Ensure that halogen analyzer-chart recorders used in lieu of manual tests and logs are calibrated at the beginning of bunkering or production, and the calibration is recorded on the chart or in a log book.
Item No.: 39
Site: Buffet-Patio Grill
Violation: One large fly was over the soup station. The soup station was in use at the time of the inspection.
Recommendation: Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
Item No.: 16
Site: Galley-Patio Grill
Violation: One bowl of tomato salsa prepared on the vessel was not marked to indicate the discard date in the reach-in refrigerator behind the buffet line. It was unknown during the inspection whether the salsa would be consumed within 24 hours.
Recommendation: Ensure that refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours is clearly marked at the time of preparation to indicate the date or day by which the food shall be consumed, which is 7 calendar days or fewer from the day the food is prepared with the day of preparation counting as day 1.
Item No.: 33
Site: Buffet-Patio Grill
Violation: Soft sealant was used as coving at the deck/counter juncture on the passenger side of the buffet.
Recommendation: Use a semi-hard or hard material on all junctures requiring coving.
Item No.: 24
Site: Bar-Patio
Violation: The utensil surface temperature of the single rack warewash machine was below 152°F as measured by the inspector's thermometer. The machine was taken out of service and a work order was put in place. There was another warewash machine that was operating properly in the same area.
Recommendation: In a mechanical operation, ensure that the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F), or less than: (1) For a stationary rack, single temperature machine, 74°C (165°F); or (2) For all other machines, 82°C (180°F); or (3) A utensil surface temperature of 71°C (160°F) as measured by an irreversible registering temperature indicator shall be achieved.
Item No.: 27
Site: Galley-Port Side Beverage Station
Violation: The utensil storage locker was soiled with crumbs, dust, and food debris.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program