Item No.:
08
|
|
Site:
Potable Water-Cross-Connection Control Program
|
|
Violation:
The plumbing connection or fixture (e.g., bucket fill station, overhead sprayer) was not included for several of the devices on the backflow prevention device list. In addition, the air gap for the evaporator high salinity discharge line was not listed.
|
|
Recommendation:
Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Bunkering and Production Records
|
|
Violation:
For the month of May 2011, the times of the calibration checks for the halogen analyzer chart recorder were not recorded on the chart or log.
|
|
Recommendation:
Ensure that halogen analyzer-chart recorders used in lieu of manual tests and logs are calibrated at the beginning of bunkering or production, and the calibration is recorded on the chart or in a log book.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Port and Starboard Bunkering Stations
|
|
Violation:
One potable water hose in each hose locker was not labeled 'Potable Water Only' at each connecting end. In addition, the connecting ends of both hoses in each locker were not capped or coupled together.
|
|
Recommendation:
Ensure that potable water hoses are labeled for use with the words "potable water only" in letters at least 13mm (0.5 inch) at each connecting end. Ensure that potable water hoses are stowed rolled tight with the ends capped, on reels, or racks or with ends coupled together in potable water hose lockers.
|
|
|
Item No.:
02
|
|
Site:
Medical-Specimen Collection
|
|
Violation:
There were no specimen collection containers for bacteriological agents. There were also no shipping containers or labels.
|
|
Recommendation:
Ensure that at least 10 clinical specimen collection containers for both viral and bacteriological agents (10 each), as well as the proper shipping containers and labels for same, are maintained by the medical staff.
|
|
|
Item No.:
10
|
|
Site:
Other-Cabin 604 Whirlpool
|
|
Violation:
The whirlpool in cabin 604 was cleaned and disinfected only between occupancies, and not weekly. According to the staff, the whirlpool was cleaned and disinfected on turnaround day only, but some of the cruises were as long as 12 days.
|
|
Recommendation:
Ensure that private whirlpool spas located in individual passenger cabins are cleaned and disinfected, including associated recirculation systems, between occupancies or weekly, whichever is more frequent.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Training Certificates
|
|
Violation:
There were no training certificates for the pest control personnel. According to the staff, a request had been made in April 2011 for training certificates.
|
|
Recommendation:
Ensure that the training of the pest-control personnel is documented in the Integrated Pest Management Plan.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Bridge Window Washing System
|
|
Violation:
There was no air gap between the vent and the funnel below the vent on the reduced pressure assembly for the potable water connection, and the end of the drain line connected to the funnel could not be located.
|
|
Recommendation:
Provide an air gap between the vent and the funnel, or ensure there is an air break at the end of the funnel drain line.
|
|
|
Item No.:
16
|
|
Site:
Galley-
|
|
Violation:
The staff explained that yogurt and butter placed out for service on the buffet lines during breakfast were brought back to the refrigerator in the galley at the end of the service period and not discarded. The written time control plan stated that foods placed out for service on the buffet lines were to be discarded at the end of the service period. The yogurt stored in the upright refrigerator had temperatures ranging from 47 °F to 48 °F and the butter had temperatures ranging from 55 °F to 56 °F. The ambient temperature of the refrigerator was 40 °F.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less. Ensure the time control operations match the written plan.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-Time Only as a Public Health Control Plans
|
|
Violation:
The written time control plans for both the hot and cold foods listed examples of foods, but also included a statement that all hot and cold foods were to be on time control. It was not clear what foods were to be on time control. The plans appeared to be generic and not specific to the vessel operations. This was noted in the previous inspection.
|
|
Recommendation:
Ensure the time control plans reflect the vessel operations by either listing the specific foods on time control, or confirming that all foods should be on time control and including a statement indicating that in the plan.
|
|
|
Item No.:
31
|
|
Site:
Galley-
|
|
Violation:
A can of insecticide for flying insects was stored inside the cleaning locker. The can was removed.
|
|
Recommendation:
Ensure that pesticides, insecticides, and rodenticides are stored in a locked area of the vessel that is not in a food area.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Dinning Room
|
|
Violation:
The deck and bulkhead juncture behind the coffee and soup stations was not coved.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
|
|
|
Item No.:
31
|
|
Site:
Room Service-
|
|
Violation:
A can of insecticide for flying insects was stored in the cleaning locker. The can was removed.
|
|
Recommendation:
Ensure that pesticides, insecticides, and rodenticides are stored in a locked area of the vessel that is not in a food area.
|
|
|
Item No.:
19
|
|
Site:
Galley-Garde Manger
|
|
Violation:
Six working containers with white powder, green leaves, and crushed nuts were unlabeled. This was corrected.
|
|
Recommendation:
Ensure that working containers holding food or food ingredients that are removed from their original packages for use on the vessel, such as cooking oils, flour, herbs, potato flakes, salt, spices, and sugar are identified with the common name of the food.
|
|
|
Item No.:
16
|
|
Site:
Galley-Hot Galley
|
|
Violation:
Fresh eggs stored in the undercounter refrigerator had internal temperatures ranging from 57 °F to 58 °F. The ambient temperature of the refrigerator was 40 °F. The eggs were discarded.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
|
|
|
Item No.:
27
|
|
Site:
Galley-Hot Galley
|
|
Violation:
The chute of the previously-cleaned grooved grill was soiled with food residue. This grill was not in use at the time of the inspection.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
39
|
|
Site:
Galley-Pastry
|
|
Violation:
A small fly was flying over the food preparation area. Several uncovered containers with exposed food were in the area at the time of the inspection.
|
|
Recommendation:
Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
|
|
|
Item No.:
20
|
|
Site:
Galley-Potwash
|
|
Violation:
Four out of twelve cutting boards were scratched and scored.
|
|
Recommendation:
Ensure that surfaces such as cutting blocks and boards that are subject to scratching and scoring are resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
|
|
|
Item No.:
16
|
|
Site:
Buffet-Officers Mess
|
|
Violation:
Individual yogurt containers stored inside the portable upright refrigerator had temperatures ranging from 42 °F to 44 °F. The ambient temperature of this refrigerator was 40°F. The containers were moved to an undercounter refrigerator with an ambient temperature of 38 °F.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
|
|
|
Item No.:
21
|
|
Site:
Provisions-Wine and Beverage Walk-In Cooler
|
|
Violation:
The four wooden pallets holding bottled water cases had very rough surfaces.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
19
|
|
Site:
Provisions-Wine and Beverage Walk-In Cooler
|
|
Violation:
A bottle of champagne was stored directly on the deck under the evaporative condenser. This was corrected.
|
|
Recommendation:
Ensure that food is protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
20
|
|
Site:
Preparation Room-Fruit & Vegetable
|
|
Violation:
The blades of the slicer were heavily corroded in several areas.
|
|
Recommendation:
Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
|
|
|
Item No.:
26
|
|
Site:
Preparation Room-Fruit & Vegetable
|
|
Violation:
The previously-cleaned slicer was soiled with food residue. This slicer was not in use at the time of the inspection.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
19
|
|
Site:
Preparation Room-Fruit & Vegetable
|
|
Violation:
An insect control device was located directly over the slicer and the food preparation counter.
|
|
Recommendation:
Ensure that the insect devices are not located over food storage, preparation, and service areas and dead insects and insect fragments are prevented from being impelled onto or falling on exposed food.
|
|
|
Item No.:
38
|
|
Site:
Preparation Room-Fruit & Vegetable
|
|
Violation:
The potato peeler and the undercounter dishwash machine were out of order. The staff explained that these pieces of equipment had been out of order for several months.
|
|
Recommendation:
Repair, replace, or remove the out of order equipment.
|
|
|
Item No.:
21
|
|
Site:
Bar-Main Lounge and Observatory Lounge
|
|
Violation:
The espersso machines on the counters were not easily movable, sealed to the table, or elevated on legs.
|
|
Recommendation:
Ensure that table-mounted equipment that is not easily movable is installed to allow cleaning of the equipment and areas underneath and around the equipment by being: (1) Sealed to the table; or (2) Elevated on legs.
|
|
|
Item No.:
27
|
|
Site:
Bar-Main Lounge
|
|
Violation:
The counter under the espresso machine was heavily soiled with a dry brown material.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
38
|
|
Site:
Bar-Observatory Lounge
|
|
Violation:
The undercounter refrigerators were out of order. The staff explained that these refrigerators had been out of order for several months.
|
|
Recommendation:
Repair, replace, or remove the out of order equipment.
|
|