Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Azamara Journey Cruise Line: Azamara Cruises Inspection Date: 10/25/2011 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 36
Site: Dining Room-Discovery
Violation: There was less than 220 lux of light at most of the waiter stations when all the lights were on.
Recommendation: In dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
Item No.: 29
Site: Buffet-Portable Handsinks
Violation: Both portable handsinks located behind the buffet lines (Port & Aft) were not able to provide water of at least 100°F (38°C).
Recommendation: Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet.
Item No.: 19
Site: Buffet-Self Service Utensils
Violation: Several individual food containers (broccoli, cut melon, chicken sausage, pork sausage) on the buffet line did not have its own dedicated service utensils.
Recommendation: Provide food-dispensing utensils for each container displayed at a consumer self-service unit such as a buffet or salad bar.
Item No.: 16
Site: Buffet-Consumer Advisory
Violation: There was no consumer advisory located at the port side buffet station where raw fish was available (smoked salmon, herring in tomato sauce, raw halibut, smoked trout).
Recommendation: If fish is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using placards or other easily visible written means of the significantly increased risk to certain populations especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served.
Item No.: 21
Site: Buffet-Beverage Stations
Violation: Three Scotsman ice dispensing machines (counter models) at all three of the beverage stations (port, aft, starboard) had exposed foam behind the ice dispenser chute. It appears that plates for this area on all the machines were missing.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 27
Site: Buffet-Port Side Beverage Station
Violation: The Scotsman counter model ice dispensing machine had exposed soiled foam behind the ice dispenser chute.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Buffet-Aft Buffet Line
Violation: There was a gap where the two middle technical compartments meet under the buffet line creating a void space.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Buffet-Aft Buffet Line
Violation: The middle technical compartment below the buffet line was soiled with food debris buildup.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 19
Site: Buffet-Buffet Line
Violation: The lids on the grits and oatmeal containers set out for passenger self service were not self-closing hinged lids nor was there an effective means of protection such as a sneeze guard.
Recommendation: Protect food on display from contamination by the use of self-closing hinged lids or other effective means such as sneeze guards.
Item No.: 21
Site: Buffet-Pool Grill
Violation: There was an open seam around the grease chute where it penetrates into the grease pan housing on the grooved grill.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Food Service General-
Violation: The sealant on the backplate of the grease catch bin housing was either missing or peeling on most of the grooved and flat grills throughout the galleys.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 21
Site: Buffet-Pool Grill
Violation: The panels around the bottom of the Baine Marie in the left technical compartment were loose, exposing the insulation. It was observed that duct tape had been used previously to hold the panels in place.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 27
Site: Buffet-Pool Grill
Violation: The far left technical compartment under the Baine Marie was soiled with food residue.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 16
Site: Buffet-Pool Grill
Violation: The time control plan posted at the Pool Grill did not specify how the PHF entering time control is being identified. This is necessary because the set-up and discard time for the outlet exceeds four hours.
Recommendation: Ensure time control plan: (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
Item No.: 16
Site: Dining Room-Prime Sea Menu
Violation: The menu had a consumer advisory on the bottom but it did not specify to which food items the advisory is intended. An asterisk should be placed on all food items that require a consumer advisory.
Recommendation: Ensure that the consumer advisory disclosure is made on a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 18
Site: Galley-Prime Sea and Aqualina Cold Pantry
Violation: One Lexan container of raw shell eggs was stored on a shelf above ready to eat lettuce and other vegetables. The container of raw eggs was moved to the bottom shelf.
Recommendation: Protect food from cross-contamination by physically separating raw animal foods during storage from ready-to-eat food so that products do not physically touch and products cannot not drip into another.
Item No.: 20
Site: Galley-Prime Sea and Aqualina
Violation: There were four slotted fasteners on the left side of the Baine Marie in the splash area.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 37
Site: Galley-Dishwash
Violation: There was condensation on the deckhead above the flight type Hobart dishwasher. The exhaust entry pipe to the ventilation duct was not totally enclosed by the ventilation duct, thus, possibly contributing to the condensation buildup.
Recommendation: Ensure ventilation devices operate effectively to prevent condensate from collecting on the bulkheads and deckheads.
Item No.: 10
Site: Recreational Water Facilities-Analyzer Chart Recorders
Violation: The sample points for the analyzer chart recorders for all of the recreational water facilities onboard were located after the compensation tank.
Recommendation: Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration.
Item No.: 10
Site: Recreational Water Facilities-Cartridge Filter Housing Cleaning and Disinfection
Violation: There was no documentation of the replacement and disinfection of the cartridge filters. In addition, there was no documentation on the disinfection concentration and time and/or equivalent CT value.
Recommendation: Clean, rinse, and disinfect the filter housing before the new filter media is placed in it. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
Item No.: 10
Site: Recreational Water Facilities-Hair and Lint Strainer Cleaning Records
Violation: There were no records for the cleaning, rinsing, and disinfection of hair and lint strainers and lint strainer housing for all recreational water facilities.
Recommendation: Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
Item No.: 10
Site: Recreational Water Facilities-Pool Bather Load
Violation: There was no documentation of the maximum bather load for the pool.
Recommendation: Maintain documentation on the maximum bather load for each RWF. Ensure the maximum bather load is based on the following factor: one person per five gallons (19 liters) per minute of recirculation flow.
Item No.: 10
Site: Recreational Water Facilities-Turnover Rates
Violation: There was no documentation of the turnover rates for recirculation for the pool, spa-pool and spas.
Recommendation: Design recirculation systems and equipment, including chemical control equipment, filter, and pumps to maintain adequate water chemistry control while operating at the following minimum turnover rates: (1) swimming pool (VSP 2005 Construction Guidelines or earlier): 6 hours; (2) whirlpool spa: 0.5 hours; (3) spa pool: 2 hours
Item No.: 10
Site: Recreational Water Facilities-Alkalinity Testing
Violation: A test kit for testing the water quality parameter of total alkalinity was not available onboard.
Recommendation: Ensure a test kit is available for testing total alkalinity and that the reagents are not past their expiration dates.
Item No.: 10
Site: Recreational Water Facilities-Safety Signs
Violation: The safety signs for the spa pool and the whirlpools did not include the following words: 'do not use these facilities if you are experiencing diarrhea, vomiting, or fever'. There was no warning to individuals who have diabetes and for elderly persons. The safety signs for the pool did not include information on the bather load, the following words: 'do not use these facilities if you are experiencing diarrhea, vomiting, or fever' and 'shower before entering the facility'.
Recommendation: Provide safety signs for all RWFs. Ensure the signs, at a minimum, include the following words: (1) do not use these facilities if you are experiencing diarrhea, vomiting, or fever; (2) no children in diapers or who are not toilet trained; (3) shower before entering the facility; and (4) bather load #. In addition to the safety sign requirements in section 6.7.1.1.1, install a sign at each whirlpool spa and spa pool entrance listing precautions and risks associated with the use of these facilities. Include, at a minimum, cautions against use by the following: (1) individuals who are immunocompromised; (2) individuals on medication or who have underlying medical conditions such as cardiovascular disease, diabetes, or high or low blood pressure; and (3) pregnant women, elderly persons, and children. Additionally, caution against exceeding 15 minutes of exposure.
Item No.: 10
Site: Recreational Water Facilities-Pool Depth Markers
Violation: The center depth markings in feet were below the water line and were not easily visible from the deck and in the pool.
Recommendation: Prominently display the depth of each RWF that is deeper than 1 meter (3 feet) so that it can be seen from the deck and in the pool. Label depth markers in both feet and meters.
Item No.: 10
Site: Recreational Water Facilities-Pool Antientrapment Covers
Violation: The pool had gravity drainage and two drains more than 3 feet apart. During the inspection it could not be verified that these drain covers conformed with ASME A112.19.8.
Recommendation: For RWFs with gravity drainage and multiple drains (2 or more drains greater than 3 feet apart), provide either a standard design (not compliant with ASME A112.19.8) drain cover and an alarm, or an ASME A112.19.8 compliant antientrapment/antientanglement drain cover. Ensure the alarm is audible and sounds in both a continuously manned space and at the RWF. Ensure this alarm is for all draining: accidental, routine, and emergency.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: The records for the tests for the testable backflow prevention devices documented pressure differentials as the subtraction of the pressure result of stage 1 and stage 2. The documentation for the test kit stated that the differential pressure checking had to yield a result of not less than 0.140 BAR for the device to be working properly. There was no technical documentation for the testable devices themselves.
Recommendation: Review documentation for the test kit and the testable backflow preventers in order to conduct a correct differential pressure check following all instructions and recommendations.
Item No.: 41
Site: Housekeeping-Public Toilets
Violation: There were no signs advising users of the public toilet facilities to use a hand towel, paper towel, or tissue to open the door.
Recommendation: Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free.
Item No.: 43
Site: Ventilation-Deck 8 - Fan Room #505
Violation: The upright water trap was heavily soiled with black debris and white mold. This unit was last cleaned about 4 months ago.
Recommendation: Keep air handling units clean.
Item No.: 36
Site: Food Service General-
Violation: For many pieces of deck and counter-mounted equipment, there was not a minimum of 110 lux of light behind and around the equipment.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment, at a distance of 75 centimeters (30 inches) above the deck when in use.
Item No.: 36
Site: Bar-Handwash Stations
Violation: There was less than 110 lux of light at all times at the handwash stations in the bars that were evaluated. The lights above the handwash stations were connected with the other lighting that is normally lowered during operation.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at handwashing stations in bars at all times.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program