Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Silver Cloud Cruise Line: Silversea Inspection Date: 12/22/2011 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 27
Site: Galley-La Terraza
Violation: The ribbed drain line below the ice machine was soiled with a black material.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Galley-La Terraza
Violation: There was a gap between the right side of the blast chiller and the bulkhead. The profile strip was behind the ice machine.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 20
Site: Galley-La Terraza
Violation: The insulation on the inside of the front panel of the upper compartment of the ice machine was damaged and the surface was rough and difficult to clean. There was some brown staining of the surface.
Recommendation: Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition.
Item No.: 08
Site: Galley-La Terraza
Violation: Below the utility sink, the right backflow prevention device was weeping at the vent.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 34
Site: Galley-La Terraza
Violation: Below the utility sink, there was a leak at the left pipe above the backflow prevention device. This was corrected.
Recommendation: Ensure the plumbing system in the food area is maintained in good repair.
Item No.: 33
Site: Dining Room-Waiter Stations
Violation: Soft sealant was used for coving at the cabinet/deck junctures of the waiter stations in both the main restaurant and La Terraza.
Recommendation: Remove the soft sealant and replace with a hard or semi-hard material.
Item No.: 28
Site: Galley-Potwash
Violation: Three ladles on the clean storage rack were stored so that water was pooled inside the ladle.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 36
Site: Food Service General-Lighting
Violation: There was less than 110 lux of light behind and beside many pieces of counter-mounted and deck mounted-equipment such as beverage dispensers, combination ovens, stack ovens, and ice machines. This was noted in galleys, buffets, and pantries.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 21
Site: Provisions-Dry Stores
Violation: There was a small shelf on the back bulkhead where duct tape and string was used for securing each shelf for rough weather. These were difficult to clean and the tape left a residue on the shelf supports.
Recommendation: Remove the duct tape and string and replace with a more permanent solution that is smooth and easy to clean.
Item No.: 19
Site: Provisions-Dry Stores
Violation: The lowest shelf of the rack of large cans was less than 6 inches above the deck. The cans from the lowest shelf were removed.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 33
Site: Provisions-Dry Stores
Violation: Inside the room and above the entrance door, there was a large gap over the left door leaf at the deckhead juncture.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
Item No.: 16
Site: Food Service General-Consumer Advisory
Violation: There was no consumer advisory for the cold smoked salmon on the buffet line or for animal-derived foods that can be ordered undercooked in any of the menus.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., ?oysters on the half-shell,? ?hamburgers,? ?steaks,? or ?eggs?); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order OR (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 26
Site: Galley-Beverage Station
Violation: The bread slicer appeared to be cleaned, but there were crumbs on the right and left ledges inside the slicer.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 21
Site: Galley-Hot Line
Violation: In the technical compartment below the counter mixer, there was damaged insulation material and the top of one metal pipe penetration was not sealed.
Recommendation: Repair or replace the insulation. Seal the top of the pipe penetration.
Item No.: 36
Site: Galley-Hot Line
Violation: There was less than 220 lux of light at the handwashing sink by the sauce station.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 27
Site: Galley-Hot Line
Violation: In the technical compartments below the ranges and fryer there were two holes for the pins of the compartment covers. Grease had dripped through the holes and onto the ledge below the compartment. There was a heavy accumulation of grease on this ledge below each compartment.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 29
Site: Galley-Potwash
Violation: At the handwash station by the potwash, there was no hot water. This was corrected during the inspection.
Recommendation: Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
Item No.: 27
Site: Galley-Cold Pantry
Violation: In the technical compartment for undercounter refrigeration units #3 and #4, the pipes were soiled with a black material.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Galley-Cold Pantry
Violation: In the front of the technical compartment for undercounter refrigeration units #3 and #4, the top of the pipe penetration was not sealed.
Recommendation: Seal the top of the pipe penetration.
Item No.: 33
Site: Food Service General-Decks
Violation: Throughout the galleys, the grouting was chipped and recessed in the areas where the deck tile met stainless steel deck mounts and gutterways.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
Item No.: 08
Site: Food Service General-Galley Nonpotable Water Lines
Violation: The chill lines and brine lines were not identified to prevent cross-connections.
Recommendation: Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
Item No.: 26
Site: Buffet-Officer's Mess
Violation: On the juice dispenser, the splash zone around the dispensing nozzles and the lower edge of the door were soiled with juice residue.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 36
Site: Buffet-Officer's Mess
Violation: There was less than 220 lux of light at the bain marie area of the service line.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 25
Site: Buffet-Crew Mess
Violation: There was a sponge in the sanitizing bucket.
Recommendation: Restrict wiping cloths to the following: (1) Cloths used for wiping food spills are used for no other purpose; (2) Cloths used for wiping food spills are dry and used for wiping food spills from tableware and single service articles or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment; (3) Dry or wet cloths used with raw animal foods are kept separate from cloths used for other purposes. Wet cloths used with raw animal foods must be kept in a separate sanitizing solution; (4) Wet wiping cloths used with a freshly made sanitizing solution and dry wiping cloths are free of food debris and visible soil.
Item No.: 21
Site: Pantry-Deck 6
Violation: The right door of the left tall neutral cabinet had a rough weld on the center hinge, making cleaning difficult.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 20
Site: Pantry-Deck 6
Violation: In the upper compartment of the ice machine, the plastic cover of the ice cuber was cracked in several places.
Recommendation: Replace the plastic cover.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan
Violation: The OPRP did not describe how the vessel would inform passengers or crew of an outbreak, how embarking passengers would be informed of an outbreak on the previous cruise, or the procedures on returning the vessel to normal operations following an outbreak.
Recommendation: Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (1) Duties and responsibilities of each department and their staff for all the passenger and crew public areas; (2) Steps in outbreak management and control and the trigger for required action at each step. Ensure the triggers address a graduated approach to outbreak management in response to increasing case counts; (3) Disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times. Ensure the disinfectant products or systems are effective against human norovirus or an acceptable surrogate (e.g., caliciviruses); (4) Procedures for informing passengers and crew members of the outbreak. Ensure this section also includes procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage; (5) Procedures for returning the vessel to normal operating conditions after an outbreak; (6) Procedures to protect the passengers and crew from exposure to disinfectants, if not already included in the vessel?s safety management system. Ensure this protection includes: (a) Material safety data sheets (MSDSs); (b) Personal protective equipment for crew; (c) Health and safety procedures to minimize respiratory and dermal exposures to both passengers and crew.
Item No.: 10
Site: Housekeeping-Suite Whirlpool Tubs
Violation: The documentation for the whirlpool tub disinfection indicated 100 ppm, but did not include the time.
Recommendation: Clean and disinfect individual hydrotherapy pools, including associated recirculation systems, between customers. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant at 10 ppm for 60 minutes, or an equivalent CT value.
Item No.: 43
Site: Housekeeping-Shower Head Disinfection
Violation: The records for cleaning and disinfecting of shower heads did not include the concentration or contact time for disinfection.
Recommendation: Clean and disinfect shower heads every 6 months. Disinfect with an appropriate halogen-based disinfectant at 10 ppm for 60 minutes, or an equivalent CT value.
Item No.: 36
Site: Bar-Handwash Station Lighting
Violation: There was less than 110 lux of light at the handwashing stations during normal operations.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at handwashing stations in bars. In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
Item No.: 41
Site: Housekeeping-Public Toilets
Violation: There were no signs advising users to wash their hands or to use a hand towel or tissue on the door handle to exit the toilet rooms. At the public toilets by the swimming pool and on deck 7, there was no waste receptacle by the outer exit door for users to place their tissue or towel used to exit.
Recommendation: Provide the passenger and crew public toilets with a handwashing station that includes: (1) Hot and cold running water; (2) Soap; (3) A method to dry hands; (4) A sign advising users to wash hands. Equip passenger and crew public toilet facilities so persons exiting the toilet room are not required to touch the door handle with bare hands. Where toilet stalls include handwashing facilities, ensure the bare-hands-free contact begins in the toilet stall. Ensure that toilet facilities with multiple exits, such as spa dressing rooms, have bare-hands-free contact at each exit. Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free.
Item No.: 08
Site: Potable Water-Tank Maintenance Records
Violation: The records indicated that the free residual halogen was less than 5 ppm after the potable water tanks were disinfected and before they were put back into service, but the free halogen test result was not documented.
Recommendation: Flush the disinfected parts of the system with potable water or otherwise dechlorinate until the free residual halogen is less than or equal to 5.00 mg/L (ppm). Document the free halogen test result.
Item No.: 10
Site: Recreational Water Facilities-Automated Chart Recorders
Violation: There were no chart recorders installed to record pH and halogen measurements for each RWF. According to the staff, the equipment has been ordered.
Recommendation: Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration.
Item No.: 10
Site: Recreational Water Facilities-Turnover Rates and Bather Loads
Violation: There was no documentation for the turnover rates or bather loads for each RWF.
Recommendation: Maintain documentation on the maximum bather load for each RWF. Ensure the maximum bather load is based on the following factor: one person per five gallons (19 liters) per minute of recirculation flow. Design recirculation systems and equipment, including chemical control equipment, UV disinfection systems, filter, and pumps to maintain adequate water chemistry control while operating at the following minimum turnover rates: (1) swimming pool (VSP 2005 Construction Guidelines or earlier): 6 hours; (2) swimming pool (VSP 2011 Construction Guidelines or later): 4 hours; (3) children's pool: 0.5 hours; (4) wading pool: 1 hour; (5) whirlpool spa: 0.5 hours; (6) spa pool: 2 hours; (7) interactive RWF or activity pool less than 610 millimeters (24 inches) deep: 1 hour; (8) interactive RWF or activity pool greater than 610 millimeters (24 inches) deep: 2 hours; and (9) baby-only water facility: 0.5 hours. Ensure an RWF slide that is combined with a pool has a turnover rate that matches the rate for the pool.
Item No.: 10
Site: Recreational Water Facilities-Whirlpool Shock Halogenation
Violation: The halogen levels at the start and completion of shock halogenation were not recorded.
Recommendation: Test the free residual halogen both at the start and completion of shock halogenation. Superhalogenate the water in the entire RWF system to 10 ppm to include the whirlpool spa/spa pool tub, compensation tank, filter housing, and all associated piping before starting the 1-hour timing.
Item No.: 10
Site: Recreational Water Facilities-
Violation: The vessel was not monitoring for alkalinity for each RWF or combined chlorine for the swimming pool. In addition, there was no test kit available for testing alkalinity.
Recommendation: Monitor and adjust the RWF's flow rates, free and combined halogen levels, pH, total alkalinity, and clarity as recommended by the manufacturer and to maintain optimum public health protection and water chemistry. Ensure a test kit is available for testing water quality parameters, including free and total halogen levels (chlorine and bromine, where applicable), pH, and total alkalinity.
Item No.: 10
Site: Recreational Water Facilities-Hair and Lint Strainers and Housings
Violation: There were no records for the cleaning, rinsing, and disinfecting of the hair and lint strainers and housings. According to the staff, this was done weekly.
Recommendation: Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
Item No.: 10
Site: Recreational Water Facilities-Test Kit Reference Standards
Violation: There were no secondary standards for the test kit used for the RWFs and potable water. According to the staff, new test kit with standards had been ordered.
Recommendation: Where available, ensure appropriate secondary standards are onboard for electronic test kits to verify test kit operation.
Item No.: 10
Site: Recreational Water Facilities-Antientrapment
Violation: The swimming pool had two gravity drains greater than one meter apart, but there was no documentation that the drain covers were antientrapment and there was no alarm installed for draining. The whirlpools had multiple blockable suction drains less than one meter apart. The drain covers were not stamped to indicate that they were antientrapment and there was no safety vacuum release system or automatic pump shut-off installed.
Recommendation: For RWFs with gravity drainage and multiple drains (2 or more drains greater than 3 feet apart), provide either a standard design (not compliant with ASME A112.19.8) drain cover and an alarm, or an ASME A112.19.8 compliant antientrapment/antientanglement drain cover. Ensure the alarm is audible and sounds in both a continuously manned space and at the RWF. Ensure this alarm is for all draining: accidental, routine, and emergency. For RWFs with suction fittings and a single blockable drain or multiple drains (less than 3 feet apart), provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a safety vacuum release system or automatic pump shut-off system.
Item No.: 08
Site: Potable Water-Distillate Lines
Violation: The distillate lines from the evaporators to the potable water chlorination station were not striped blue/gray/blue.
Recommendation: Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers.
Item No.: 08
Site: Potable Water-Garbage Room
Violation: The backflow prevention device installed on the potable water line to the pulper had a plug in the vent and the vent was pointed up. When the plug was removed, liquid drained from the vent. According to the staff, the pulper had been out of order for about two months and would be repaired in the next dry dock.
Recommendation: Do not plug the backflow prevention device vent. Repair or replace the backflow prevention device. Ensure the device is installed with the vent pointing down.
Item No.: 08
Site: Potable Water-Garbage Room
Violation: The potable water lines to the pulper and to the handwash sink were not striped blue or blue/green/blue.
Recommendation: Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only.
Item No.: 02
Site: Medical-Acute Gastroenteritis (AGE) Surveillance Log
Violation: The AGE log did not meet the requirements of the new VSP Operations Manual. There was no column for time of report to medical, and the column for date of report to medical was not in the exact order specified in Annex 13 of the 2011 VSP Operations Manual.
Recommendation: Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Date of the first medical visit or report to staff of illness; (2) time of the first medical visit or report to staff of illness; (3) case identification number; (4) person?s name; (5) person?s age; (6) person?s sex; (7) designation as passenger or crew member; (8) crew member position or job on the vessel, if applicable; (9) cabin number; (10) meal seating information; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24-hour period; (b) number of episodes of vomiting in a 24-hour period; (c) bloody stools; (d) recorded temperature; (e) abdominal cramps; (f) headaches; (g) muscle aches; (14) entry (yes/no) for whether this was a reportable case; (15) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (16) presence of underlying medical conditions that may affect interpretation of AGE. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP.
Item No.: 19
Site: Other-Housekeeping Office
Violation: Several cases of water and champagne and cans of soda were stored either on the deck or on the lowest shelf of a shelving unit that was not 6 inches above the deck. There were also boxes of shampoo and lotion stored adjacent to some of the beverage boxes. According to the staff, these items are for the cabins, and are only stored in this office on embarkation day.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 31
Site: Other-Housekeeping Office
Violation: Cases of water and champagne were stored on the deck adjacent to boxes of shampoo and lotion.
Recommendation: Ensure only poisonous or toxic materials that are required for the operation and maintenance of a food area of the vessel, such as for the cleaning and sanitizing of equipment and utensils and the control of insects and rodents, are allowed in the food areas of the vessel.
Item No.: 33
Site: Other-Housekeeping Office
Violation: Beverages were stored in this office, but the deck was carpeted and there was no coving at the deck/bulkhead juncture.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
Item No.: 10
Site: Recreational Water Facilities-Safety Signs
Violation: The combined safety signs for the whirlpools and pool did not include the following information: do not use these facilities if you are experiencing diarrhea, vomiting, or fever; no children in diapers or who are not toilet trained; and bather load number for the pool. In addition, at the whirlpools there were no cautions against use by: individuals on medication or who have low blood pressure; and pregnant women, elderly persons, and children. Additionally, there was no caution against exceeding 15 minutes of exposure.
Recommendation: Provide safety signs for all RWFs, except for baby-only water facilities. Ensure the signs, at a minimum, include the following words: (1) do not use these facilities if you are experiencing diarrhea, vomiting, or fever; (2) no children in diapers or who are not toilet trained; (3) shower before entering the facility; and (4) bather load #. In addition to the safety sign requirements in section 6.7.1.1.1, install a sign at each whirlpool spa and spa pool entrance listing precautions and risks associated with the use of these facilities. Include, at a minimum, cautions against use by the following: (1) individuals who are immunocompromised; (2) individuals on medication or who have underlying medical conditions such as cardiovascular disease, diabetes, or high or low blood pressure; and (3) pregnant women, elderly persons, and children. Additionally, caution against exceeding 15 minutes of exposure.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program