Item No.:
16
|
|
Site:
Bar-Coffee Counter
|
|
Violation:
Cold counters one and two were on time control and listed on the time control plan, but the units were not labeled.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Turnover Rates
|
|
Violation:
The turnover rates for each RWF were not available.
|
|
Recommendation:
For RWFs with skim gutters, ensure that the fill level of the RWF is to the level of the skim gutters. Design recirculation systems and equipment, including chemical control equipment, UV disinfection systems, filter, and pumps to maintain adequate water chemistry control while operating at the following minimum turnover rates: (1) swimming pool (VSP 2005 Construction Guidelines or earlier): 6 hours; (2) swimming pool (VSP 2011 Construction Guidelines or later): 4 hours; (3) children's pool: 0.5 hours; (4) wading pool: 1 hour; (5) whirlpool spa: 0.5 hours; (6) spa pool: 2 hours; (7) interactive RWF or activity pool less than 610 millimeters (24 inches) deep: 1 hour; (8) interactive RWF or activity pool greater than 610 millimeters (24 inches) deep: 2 hours; and (9) baby-only water facility: 0.5 hours. Ensure an RWF slide that is combined with a pool has a turnover rate that matches the rate for the pool.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Bather Loads
|
|
Violation:
The bather load calculations for each RWF were not available.
|
|
Recommendation:
Maintain documentation on the maximum bather load for each RWF. Ensure the maximum bather load is based on the following factor: one person per five gallons (19 liters) per minute of recirculation flow.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Safety Signs
|
|
Violation:
The safety signs for the swimming pool and the whirlpool did not include: 'Do not use these facilities if you are experiencing diarrhea, vomiting, or fever;' or the bather load.
|
|
Recommendation:
Provide safety signs for all RWFs, except for baby-only water facilities. Ensure the signs, at a minimum, include the following words: (1) do not use these facilities if you are experiencing diarrhea, vomiting, or fever; (2) no children in diapers or who are not toilet trained; (3) shower before entering the facility; and (4) bather load #.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Anitentrapment Protection
|
|
Violation:
The swimming pool had dual gravity drains great than 3 feet apart, and it could not be determined if the drain covers met antientrapment standards. There was no alarm installed.
|
|
Recommendation:
For RWFs with gravity drainage and multiple drains (2 or more drains greater than 3 feet apart), provide either a standard design (not compliant with ASME A112.19.8) drain cover and an alarm, or an ASME A112.19.8 compliant antientrapment/antientanglement drain cover. Ensure the alarm is audible and sounds in both a continuously manned space and at the RWF. Ensure this alarm is for all draining: accidental, routine, and emergency.
|
|
|
Item No.:
43
|
|
Site:
Housekeeping-Shower Head Disinfection
|
|
Violation:
The shower head log listed the disinfection at 100 ppm of chlorine, but did not include a contact time. According to the staff, the shower heads were disinfected for 10 minutes.
|
|
Recommendation:
Clean and disinfect shower heads every 6 months. Disinfect with an appropriate halogen-based disinfectant at 10 ppm for 60 minutes, or an equivalent CT value.
|
|
|
Item No.:
36
|
|
Site:
Food Service General-Lighting
|
|
Violation:
The light intensity was less than 220 lux along the work surface of the band saw in the butcher preparation room, on all preparation/work surfaces at the La Veranda starboard buffet line, at all of the waiter stations in the Compass dining room, and at the work surface at the coffee counter bar.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
39
|
|
Site:
Preparation Room-Vegetable/Fruit/Bakery/Potwash
|
|
Violation:
Seven live fruit flies were observed along the bulkhead and deckhead above the soiled landing of the 3-compartment potwash sink, The area was not in operation at the time of the inspection. In addition, four live three live fruit flies were observed along the bulkhead immediately above the dough-sheeter, which was in operation.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
36
|
|
Site:
Bar-Coffee Counter Deck 6
|
|
Violation:
The light intensity was less than 110 lux at the handwashing sink even with maximum lighting.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at handwashing stations in bars.
|
|
|
Item No.:
36
|
|
Site:
Food Service General-Light Intensity
|
|
Violation:
The light intensity was less than 110 lux around and behind many different deck-mounted and counter-mounted equipment such as the WMF coffee station on deck 6, the deck convection oven in pastry, the cuber and crushed ice machine near the main galley potwash and pastry, several pieces of counter-mounted equipment on the beverage line in the crew mess, behind the three combination ovens in the main galley, and deck-mounted ice machines in the starboard main galley.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
24
|
|
Site:
Buffet-La Veranda Starboard
|
|
Violation:
A bucket of sanitizer solution was less than 50 ppm free residual halogen.
|
|
Recommendation:
Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
|
|
|
Item No.:
33
|
|
Site:
Buffet-La Veranda Starboard
|
|
Violation:
Worn and recessed coving was noted on the worker side of the buffet line and on the bulkhead/deck juncture which made cleaning of the area difficult.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
21
|
|
Site:
Galley-La Veranda
|
|
Violation:
The protective insulation covering on the hot water line of the bain marie was torn and fraying, and a small amount of moisture had accumulated.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
21
|
|
Site:
Galley-La Veranda and Room Service
|
|
Violation:
Seams were noted where the coffee grinder stands were tack welded to the food preparation counters which made cleaning of the area difficult.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
20
|
|
Site:
Galley-La Veranda Starboard
|
|
Violation:
Slotted screws secured the metal cuber along the food contact surface.
|
|
Recommendation:
Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
15
|
|
Site:
Galley-La Veranda Starboard
|
|
Violation:
Food residue that appeared to be a piece of tomato was in direct contact with crushed ice. The ice machine was removed from service and cleaned and sanitized.
|
|
Recommendation:
Ensure food is safe and unadulterated.
|
|
|
Item No.:
30
|
|
Site:
Galley-Pastry
|
|
Violation:
A 'Wash Hands Often' sign was not found at the handwashing sink.
|
|
Recommendation:
Post a sign over handwashing sinks stating "WASH HANDS OFTEN" in a language that the food employees understand.
|
|
|
Item No.:
37
|
|
Site:
Galley-
|
|
Violation:
Excessive condensation from the conveyor flight-type conveyor warewash machine was collecting on the deckhead and dripping on the deck.
|
|
Recommendation:
Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them.
|
|
|
Item No.:
22
|
|
Site:
Galley-Warewashing
|
|
Violation:
The data plate on the warewashing machine #369 did not include the final rinse pressure. It was determined from the specification sheet that the proper pressure was needed in order for the machine to operate properly.
|
|
Recommendation:
Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine's design and operating specifications including the: (1) wash tank, rinse tank(s) if present, and final sanitizing rinse temperatures; (2) pressure required for the fresh water sanitizing rinse unless the machine is designed to use only a pumped sanitizing rinse; (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines.
|
|
|
Item No.:
22
|
|
Site:
Galley-Warewashing Port
|
|
Violation:
A data plate with the required operational paramaters was not found on the conveyor flight-type machine #364.
|
|
Recommendation:
Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine's design and operating specifications including the: (1) wash tank, rinse tank(s) if present, and final sanitizing rinse temperatures; (2) pressure required for the fresh water sanitizing rinse unless the machine is designed to use only a pumped sanitizing rinse; (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines.
|
|
|
Item No.:
08
|
|
Site:
Food Service General-Refrigerant Brine Lines
|
|
Violation:
The refrigerant brine lines to the ice machines and refrigerators were not uniquely identified.
|
|
Recommendation:
Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
|
|
|
Item No.:
30
|
|
Site:
Other-Crew Toilet Room
|
|
Violation:
Paper towel dispensers or paper towels were not provided in the male, female, or main handwashing sinks at the crew toilet room adjacent to the crew mess and galley.
|
|
Recommendation:
Ensure each handwashing facility has a supply of hand-cleansing soap or detergent and a supply of single-service paper towels available.
|
|
|
Item No.:
41
|
|
Site:
Other-Crew Toilet Room
|
|
Violation:
The waste receptacles were placed away from the exit doors to the male and female restrooms, which made exiting without using bare hands contact difficult. Also, there was no sign advising users to exit the toilet rooms using a paper towel or tissue.
|
|
Recommendation:
Equip the toilet rooms so persons exiting the toilet room are not required to handle the door with bare hands. Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free.
|
|
|
Item No.:
22
|
|
Site:
Galley-Warewashing
|
|
Violation:
The final rinse pressure of the flight-type conveyor warewash machine #363 was above 30 psi, which was higher than the range specified by the manufacturer.
|
|
Recommendation:
Ensure the flow pressure of the fresh hot water sanitizing rinse in a warewashing machine is not less than 34.5 kilopascals (5 pounds per square inch or 0.34 bars) or more than 207 kilopascals (30 pounds per square inch or 2.07 bars) as measured in the water line immediately downstream or upstream from the fresh hot water sanitizing rinse control valve. Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-Consumer Advisories
|
|
Violation:
Consumer advisories for the animal-derived food items served in La Veranda and Compass Rose that could be ordered raw or undercooked.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., "oysters on the half-shell," "hamburgers," "steaks," or "eggs"); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order OR (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
|
|
|
Item No.:
18
|
|
Site:
Galley-Hot Line
|
|
Violation:
One pan of raw lamb chops was found stored in undercounter refrigerator #337 above several containers of butter, one container of shredded cheese, and one container of cooked, ready-to-eat ham.
|
|
Recommendation:
Protect food from cross-contamination or other sources of contamination by the following methods: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food so that products do not physically touch and so that one product does not drip into another. (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry-except when combined as ingredients-during storage, preparation, holding, and display by using separate equipment for each type, or by arranging each type of food in equipment so that cross-contamination of one type with another is prevented, or by preparing each type of food at different times or in separate areas. (3) Cleaning and sanitizing equipment and utensils. (4) Storing the food in packages, covered containers, or wrappings. (5) Cleaning visible soil on hermetically sealed containers of food before opening. (6) Protecting food containers that are received packaged together in a case or overwrap from cuts when the case or overwrap is opened. (7) Separating damaged, spoiled, or recalled food being held on the vessel. (8) Separating unwashed fruits and vegetables from ready-to-eat food.
|
|
|
Item No.:
22
|
|
Site:
Galley-La Veranda
|
|
Violation:
A required operational parameter data plate was not provided on the rack- type machine #357. The data plate on rack-type machine #356 did not include the final rinse pressure. The specifications of the machine indicated the final rinse pressure needed to be regulated at a specific pressure to be operating properly. Also, the wash and final rinse internal temperature gauges were not working properly on warewash machine #357. The temperatures did not change while the machine was operating. The internal temperature gauge for warewash machine #356 was missing.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use. Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine's design and operating specifications including the: (1) wash tank, rinse tank(s) if present, and final sanitizing rinse temperatures; (2) pressure required for the fresh water sanitizing rinse unless the machine is designed to use only a pumped sanitizing rinse; (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines.
|
|
|
Item No.:
20
|
|
Site:
Galley-La Veranda
|
|
Violation:
Two in--use cutting boards were significantly scratched and scored. The boards were removed from service.
|
|
Recommendation:
Ensure surfaces such as cutting blocks and boards that are subject to scratching and scoring are resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
|
|
|
Item No.:
30
|
|
Site:
Buffet-Pool Grill Cold Counter BBQ
|
|
Violation:
Paper towels and a 'Wash Hands Often' sign were not provided at the handwashing station. This was corrected.
|
|
Recommendation:
Ensure each handwashing facility has a supply of hand-cleansing soap or detergent and a supply of single-service paper towels available. Post a sign over handwashing sinks stating "WASH HANDS OFTEN" in a language that the food employees understand.
|
|
|
Item No.:
33
|
|
Site:
Dining Room-Pool Grill Waiter Station and BBQ Cold Counter
|
|
Violation:
Soft sealant used as coving material for the deck/counter junctures was peeling, creating a difficult to clean surface.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
39
|
|
Site:
Dining Room-Pool Grill Coffee Station Aft
|
|
Violation:
A small fly was below the technical compartment.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
08
|
|
Site:
Dining Room-Pool Grill Coffee Station Aft
|
|
Violation:
The backflow prevention device in the technical compartment was leaking at the atmospheric vent. The device was replaced during the inspection.
|
|
Recommendation:
Maintain backflow prevention devices in good repair.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Pool Grill
|
|
Violation:
Worn and recessed coving was noted at the worker side of the buffet which made the cleaning of this area more difficult.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
16
|
|
Site:
Galley-Pool Grill
|
|
Violation:
Cold units 167, 168, and 172 were identified as being on time control on the time control plan but the actual units were not labeled.
|
|
Recommendation:
If time only-rather than time in conjunction with temperature-is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control. (2) Is not be placed on temperature control again. (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours. and (4) Is discarded within 4 hours of placement on time control.
|
|
|
Item No.:
20
|
|
Site:
Food Service General-Tip-sensitive Thermometers
|
|
Violation:
Cooks responsible for measuring the temperatures of thin foods did not have tip-sensitive thermometers.
|
|
Recommendation:
Ensure food temperature-measuring devices are provided and readily accessible for use in ensuring attainment and maintenance of food temperatures. Use tip-sensitive temperature-measuring devices, such as a thermocouple or thermistor, for measuring thin food products.
|
|
|
Item No.:
24
|
|
Site:
Galley-La Veranda
|
|
Violation:
The in-use single stationary rack hood-type warewash machine had a final rinse temperature of 149°F at the utensil surface.
|
|
Recommendation:
In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
|
|