Cruise Ship: Seadream I Cruise Line: Sea Dream Yacht Club Inspection Date: 12/17/2011 Inspection Score: 95
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Potable Water-Bunkering - Potable Water Hoses
Violation: During the bunkering of potable water, a few segments of the hose were in stagnant water on the pier. A work order for more hose supports was on file.
Recommendation: Handle potable water hoses with care to prevent contamination from dragging their ends on the ground, pier, or deck surfaces, or from dropping the hose into contaminated water.
Item No.: 08
Site: Potable Water-Permeate Water Lines
Violation: The permeate water lines from the reverse osmosis system to the potable water system were not striped or painted in accordance with ISO 14726 standards (blue/gray/blue).
Recommendation: Stripe or paint permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue).
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: The list of backflow preventers indicated testing for nearly all devices which cannot be tested. It was unclear from the list if the various backflow prevention devices in the engine room were inspected since the last date recorded was December 2005. In addition, there were air gaps listed where the comment under the inspected date was 'none needed'. For example, the boiler feed filling air gap was one which requires routine inspection. These violations were noted in the past inspection.
Recommendation: Update the cross-connection control program to include routine inspection of non-testable devices, including air gaps. Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
Item No.: 10
Site: Recreational Water Facilities-Pool
Violation: The depth marker listed depth only in meters.
Recommendation: Label depth markers in both feet and meters.
Item No.: 10
Site: Recreational Water Facilities-Safety Sign
Violation: The safety sign posted for both the pool and the spa did not contain all elements of the 2011 VSP Operations Manual sign requirements.
Recommendation: Provide safety signs for all RWFs, except for baby-only water facilities. Ensure the signs, at a minimum, include the following words: (1) do not use these facilities if you are experiencing diarrhea, vomiting, or fever; (2) no children in diapers or who are not toilet trained; (3) shower before entering the facility; and (4) bather load #. In addition to the safety sign requirements in section 6.7.1.1.1, install a sign at each whirlpool spa and spa pool entrance listing precautions and risks associated with the use of these facilities. Include, at a minimum, cautions against use by the following: (1) individuals who are immunocompromised; (2) individuals on medication or who have underlying medical conditions such as cardiovascular disease, diabetes, or high or low blood pressure; and (3) pregnant women, elderly persons, and children. Additionally, caution against exceeding 15 minutes of exposure.
Item No.: 10
Site: Recreational Water Facilities-Antientrapment Requirements
Violation: The drain for the swimming pool did not meet the antientrapment drain requirements per the 2011 VSP Operations Manual. The pool drain had a suction fitting, a single unblockable drain, and a ASME A112.19.8-2007 compliant cover. However, there was no safety vacuum release system (SVRS) or automatic pump shut-off system (APS).
Recommendation: For RWFs with suction fittings and a single unblockable drain (per ASME A112.19.8-2007), provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a safety vacuum release system or automatic pump shut-off system.
Item No.: 10
Site: Recreational Water Facilities-Water Testing
Violation: There was no means to test the total chlorine and alkalinity for the water in the recreational water facilities.
Recommendation: Ensure a test kit is available for testing water quality parameters, including free and total halogen levels (chlorine and bromine, where applicable), pH, and total alkalinity.
Item No.: 07
Site: Potable Water-Skin Tanks Variance
Violation: The ship had an approved variance to have potable water tanks sharing a wall with the hull of the vessel based on the use of salinity sensors, alarms, and a monitoring plan. The variance's hazard analysis and critical control points (HACCP) plan stated that routine maintenance checks, carried out by a third party, had to be performed every six months on the salinometer and alarm system. However, the last maintenance checks were performed on an annual basis, with checks dated 26 August 2010 and 2 August 2011. In addition, conductivity tests were to be performed and recorded every four hours. However, on the day of the inspection, for all six potable water tanks the test was done at 07:00 but at 13:45, no other test had been performed. Additionally, the variance approval letter was not on file.
Recommendation: Comply with the variance's HACCP and monitoring plans that were submitted to VSP and subsequently approved. Retain onboard all records pertaining to this variance.
Item No.: 10
Site: Recreational Water Facilities-Hair and Lint Strainer
Violation: The hair and lint strainer and hair and lint strainer housing on all the RWFs were cleaned and disinfected according to the staff, but there was no documentation regarding the frequency of cleaning, disinfectant concentration, or contact time.
Recommendation: Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
Item No.: 10
Site: Recreational Water Facilities-Filter Housing
Violation: The filter housing on the recreational water facilities were cleaned and disinfected according to the staff, but there was no documentation regarding the frequency of cleaning, disinfectant concentration, or contact time.
Recommendation: Clean, rinse, and disinfect the filter housing before the new filter media is placed in it. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
Item No.: 10
Site: Recreational Water Facilities-Turnover Rates
Violation: Turnover rates were not calculated for each recreational water facility.
Recommendation: Design recirculation systems and equipment, including chemical control equipment, UV disinfection systems, filter, and pumps to maintain adequate water chemistry control while operating at the following minimum turnover rates: swimming pool (VSP 2005 Construction Guidelines or earlier): 6 hours; whirlpool spa: 0.5 hours.
Item No.: 40
Site: Integrated Pest Management-Inspections - Garbage Handling Areas
Violation: There was no evidence that inspections of the garbage handling areas of the vessel were conducted for the presence of insects, rodents, and other pests.
Recommendation: Inspect the garbage handling areas of the vessel at least weekly for the presence of insects, rodents, and other pests. Maintain the results of these inspections in a log.
Item No.: 40
Site: Integrated Pest Management-Loading Inspections
Violation: There was no evidence of loading inspections of any nonfood items.
Recommendation: Routinely inspect incoming shipments of food and all other supplies for evidence of insects, rodents, and other pests. Maintain a record of these inspections onboard the vessel and make the record available for review during inspections.
Item No.: 40
Site: Integrated Pest Management-Mooring Lines
Violation: The rat guards on the mooring lines were not closed, making them ineffective to prevent the passage of vermin crawling along the lines from the pier to the ship. A work order for new rat guards was on file.
Recommendation: Install rat guards on the mooring lines according to the recommendations of the manufacturer. Protect entry points where pests may enter the food areas.
Item No.: 16
Site: Food Service General-Time Control Plans
Violation: The time control plans did not include the refrigeration units and milk in the coffee machines as being on time control. In addition, the coffee machine milk compartment was not physically labeled as being on time control.
Recommendation: Ensure plans list refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such).
Item No.: 21
Site: Pantry-Outside Cafe
Violation: The potable water delivery line to the coffee machine was draped on the counter, making cleaning difficult.
Recommendation: Shorten and/or support the water delivery line above the counter to allow for easy cleaning.
Item No.: 20
Site: Pantry-Outside Cafe - Beverage Station
Violation: There were two slotted fasteners in the food splash zone of the left coffee machine.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones.
Item No.: 36
Site: Food Service General-Lighting
Violation: At the pantries and the galley, the light intensity behind and around many pieces of counter-mounted and deck-mounted equipment was less than 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 33
Site: Galley-Dishwash
Violation: The hot water pipe penetration on the bulkhead-mounted bucket fill tap near the soiled landing of the dishwash machine was not sealed.
Recommendation: Install a flange around the hot water pipe.
Item No.: 21
Site: Galley-Pastry
Violation: The door gaskets on pastry freezer #10 and meat fridge #9 were loose and worn, allowing warm air to enter and cold air to exit the units. The units were at proper temperatures.
Recommendation: Ensure nonfood contact equipment is maintained in good repair and proper adjustment including equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 33
Site: Provisions-Fruit Fridge #7
Violation: There was a gap around the deckhead-mounted sprinkler, leading to a void space.
Recommendation: Close the gap.
Item No.: 27
Site: Buffet-
Violation: The technical compartment below the bain marie was soiled. This was corrected.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 25
Site: Pantry-Top Side Galley
Violation: A wet wiping cloth was draped over the side of the chemical sanitizing solution container. The cloth was placed inside the solution.
Recommendation: Store wet wiping cloths fully submerged in the sanitizing solution. Restrict wiping cloths to the following: cloths used for wiping food spills are dry and used for wiping food spills from tableware and single service articles or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment.
Item No.: 40
Site: Pantry-Top of the Yacht
Violation: The port side door leading to the pantry of this outdoor bar was fully open, allowing entry for pests into the pantry. The door remained open for a few minutes until the inspector brought it to the staff's attention and then the door was closed. Upon re-inspection of the area nearly one hour later, the door was open again and the bar was in operation.
Recommendation: Protect entry points where pests may enter the food areas.
Item No.: 40
Site: Pantry-Top of the Yacht
Violation: There was a one-inch gap between the door and the door frame on the two outside swinging doors leading to the pantry of this outdoor bar, allowing entry for pests into the pantry.
Recommendation: Protect entry points where pests may enter the food areas.
Item No.: 16
Site: Dining Room-Consumer Advisory
Violation: The menus for the main dining room contained the consumer advisory statement but did not have asterisks at the animal-derived foods that could be served raw or undercooked.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Ensure that disclosure is made on a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 02
Site: Medical-Acute Gastroenteritis (AGE) Log
Violation: The AGE surveillance log did not contain the cabin number for each ill passenger or crew member. The AGE log was corrected.
Recommendation: Ensure the AGE surveillance log entry for each passenger or crew member contain the cabin number.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan
Violation: The outbreak prevention and response plan did not include public areas and frequently touched areas, such as handrails, elevator surfaces, golf simulator, etc., as areas to be cleaned and disinfected continuously during an outbreak.
Recommendation: When the cumulative proportion of cases of AGE among passengers or crew members is equal or greater than 2%, ensure the outbreak management response includes cleaning and disinfecting all public areas, including handrails and restrooms, on a continuous basis.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan
Violation: The outbreak prevention and response plan did not include the disinfectant concentration and contact time for the bleach and Microbac used during an outbreak, procedures for informing current passengers and crew members of the outbreak and those embarking the vessel following an outbreak voyage, or procedures for returning the vessel to normal operating conditions after an outbreak.
Recommendation: Include the following in the written OPRP: disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times; procedures for informing passengers and crew members of the outbreak including procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage; procedures for returning the vessel to normal operating conditions after an outbreak.
Item No.: 41
Site: Housekeeping-Public Toilet Rooms
Violation: There were no signs in the public toilet rooms advising users to wash their hands.
Recommendation: Provide the passenger and crew public toilets with a handwashing station that includes a sign advising users to wash hands.
Item No.: 40
Site: Galley-Top Side
Violation: The door leading to the galley was fully open during the first inspection of the area. This area was on an open deck, but was not in operation. The door remained open for a few minutes until the inspector brought it to the staff's attention and then the door was closed.
Recommendation: Protect entry points where pests may enter the food areas.