Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Case Definition
|
|
Violation:
The AGE case definition used by the ship did not consider the number of diarrhea episodes that was above normal to certain individuals. The current definition did not allow individuals with pre-existing medical conditions, such as individuals with irritable bowel syndrome, who reach 3 loose stools to be considered non-reportable cases. This definition was in writing. No cases appeared to be reported incorrectly.
|
|
Recommendation:
Ensure a reportable case of AGE is a case reported to the master of the vessel, the medical staff, or other designated staff by a passenger or a crew member and meets the case definition based on the following symptoms: (1) Diarrhea (three or more episodes of loose stools in a 24 hour period or what is above normal for the individual. See section 4.1.2.1.3, illness symptoms); or (2) vomiting and one additional symptom including one or more episodes of loose stools in a 24-hour period, or abdominal cramps, or headache, or muscle aches, or fever (temperature of greater than or equal to 38°C [100.4°F]).
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Distillate & Permeate Water Lines
|
|
Violation:
The distillate water lines from the evaporators to the potable water halogen injection point and the permeate water lines from the reverse osmosis plant to the potable water halogen injection point were not striped or painted in accordance with ISO 14726 standards (blue/gray/blue).
|
|
Recommendation:
Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue).
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross-Connection Control Program
|
|
Violation:
The air gap for the mineralizer backwash drain was not listed on the cross-connection control program. This was noted in the previous inspection.
|
|
Recommendation:
Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross-Connection Control Program
|
|
Violation:
The air gap for the mineralizer backwash drain was less than twice the diameter of the delivery fixture opening.
|
|
Recommendation:
Ensure air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 25 millimeters (1 inch).
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross-Connection Control Program
|
|
Violation:
The air gaps for the two technical/laundry tank filling stations were not listed on the cross-connection control program. This was noted in the previous inspection.
|
|
Recommendation:
Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross-Connection Control Program
|
|
Violation:
The backflow prevention device for the port side evaporator had a plug into the air relief vent preventing its proper functioning. This was corrected.
|
|
Recommendation:
Maintain backflow prevention devices in good repair. Do not place a plug in or block the vent of a backflow prevention device.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Bunkering Pretest
|
|
Violation:
A pH test was conducted on the shore-side water supply before starting the bunkering process according to the staff, but no value was recorded.
|
|
Recommendation:
Conduct a free halogen residual and pH test on the shore-side water supply before starting the potable water bunkering process to establish the correct halogen dosage. Record the results of the pretest and ensure they are available for review during inspections.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Bunkering
|
|
Violation:
The first halogen and pH values were recorded 1 hour after the start of bunkering. This was noted the day of the inspection and on 17 January 2011.
|
|
Recommendation:
Adjust the free halogen residual level to at least 2.0 mg/L (ppm) within 30 minutes of the start of the bunkering and production processes. Maintain accurate records of production and bunkering monitoring aboard for 12 months and ensure these records are available for review during inspections.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross-Connection Control Program
|
|
Violation:
The reduced pressure backflow preventers for the high saline discharge line from the evaporators were not tested with a test kit after installation on 19 January 2012. Also, on 20 January 2012 the international shore connections for fire were inspected visually but were not tested with a test kit for their yearly test.
|
|
Recommendation:
Inspect and test backflow prevention devices requiring testing with a test kit after installation and at least annually. Maintain the test results showing the pressure differences on both sides of the valves for each device.
|
|
|
Item No.:
05
|
|
Site:
Potable Water-Deck 10 Far Point
|
|
Violation:
The free residual halogen measured by the halogen analyzer was not within 0.2 ppm of the free residual halogen measured by the manual test. The analyzer indicated 1.34 ppm of free chlorine, the staff's test kit indicated 0.92 ppm, and the inspector's test kit indicated 0.85 ppm. The staff recalibrated the analyzer.
|
|
Recommendation:
Ensure the free residual halogen measured by the halogen analyzer is within 0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Chart Recorders/Data Loggers
|
|
Violation:
There were no chart recorders or electronic data loggers with security features that recorded pH and halogen measurements for each individual recreational water facility.
|
|
Recommendation:
Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration. In the event of equipment failure, measure free residual halogen and pH by a manual test kit at the RWF or return line at least hourly for whirlpool spas, spa pools, children's pools, and wading pools and every 4 hours for all other RWFs. Record manual readings on a chart or log, retain for at least 12 months, and ensure that they are available for review during inspections. Complete repairs on malfunctioning halogen analyzer-chart recorders within 30 days of equipment failure. Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Fecal and Vomit Accident Response Plan
|
|
Violation:
The fecal and vomit accident response plan did not meet the required chlorine residuals and contact times to be used for disinfection after an accident involving fecal material or vomit per Annex 13.8 of the 2011 VSP Operations Manual.
|
|
Recommendation:
Ensure a fecal and vomit accident response procedure that meets or exceeds the procedure provided in Annex 13.8 is available for review during inspections.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Hair and Lint Strainer
|
|
Violation:
The hair and lint strainer and hair and lint strainer housing on the recreational water facilities were cleaned and disinfected weekly, but there was no documentation regarding the disinfectant concentration or contact time.
|
|
Recommendation:
Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Filter Housing
|
|
Violation:
The filter housing on the recreational water facilities were cleaned and disinfected weekly, but there was no documentation regarding the disinfectant concentration or contact time.
|
|
Recommendation:
Clean, rinse, and disinfect the filter housing before the new filter media is placed in it. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Center Pool
|
|
Violation:
The water fill level in the open center pool was about 1 feet over the overflow skim gutters which reduces the effectiveness of the water filtration system. No bathers were using the pool at the time of the inspection.
|
|
Recommendation:
For RWFs with skim gutters, ensure that the fill level of the RWF is to the level of the skim gutters.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Pools Shepherd's Hooks
|
|
Violation:
The center and aft pools had telescoping shepherd's hooks.
|
|
Recommendation:
Ensure it is a light, strong, nontelescoping material with rounded, nonsharp ends.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Antientrapment Drain Covers
|
|
Violation:
The drain covers of the deck 7 port whirlpool, deck 11 port and starboard whirlpools, and deck 11 aft pool were not stamped with all required information per section 6.7.1.2.2 of the 2011 VSP Operations Manual.
|
|
Recommendation:
Ensure the testing of manufactured drain covers is by a nationally or internationally recognized testing laboratory. Ensure the following information is stamped on each manufactured antientrapment drain cover: (1) certification standard and year; (2) type of drain use (single or multiple); (3) maximum flow rate (in gallons or liters per minute); (4) type of fitting (suction outlet); (5) life expectancy of cover; (6) mounting orientation (wall, floor, or both); (7) manufacturer's name or trademark; and (8) model designation.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Outbreak Prevention and Response Plan (OPRP)
|
|
Violation:
The OPRP indicated a frequency of cleaning and disinfecting all public areas during an outbreak response of every hour. The OPRP instructed to use a concentration of 1000 ppm of chlorine on frequently touched public surfaces but no contact time was indicated. The OPRP indicated the use of HB QUAT sanitizer during a precautionary measures level but the staff explained that the actual sanitizer used was TOR HB and no concentrations and contact times were indicated. The OPRP did not include procedures for informing embarking passengers and crew members of an outbreak.
|
|
Recommendation:
When the cumulative proportion of cases of AGE among passengers or crew members is equal or greater than 2%, ensure the outbreak management response includes cleaning and disinfecting all public areas, including handrails and restrooms, on a continuous basis. Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (3) Disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times. Ensure the disinfectant products or systems are effective against human norovirus or an acceptable surrogate (e.g., caliciviruses); (4) Procedures for informing passengers and crew members of the outbreak. Ensure this section also includes procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Toilet Room Signs
|
|
Violation:
Crew toilet rooms at the junior management's office and the bridge did not have signs advising users to wash hands after using the toilet or signs advising users to use hand towels, paper towel, or tissue to open the door when exiting.
|
|
Recommendation:
Provide the passenger and crew public toilets with a handwashing station that includes a sign advising users to wash hands. Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free.
|
|
|
Item No.:
31
|
|
Site:
Housekeeping-Stewardess Lockers
|
|
Violation:
Cleaning and sanitizing chemicals used for housekeeping were stored adjacent to, on and above water bottles, coffee packs, coffee creamers, tea bags, clean linens, clean cups, and clean glasses. The staff explained that there were about 28 lockers on the ship, all with the same setting.
|
|
Recommendation:
Store poisonous or toxic materials used in the cleaning and maintenance of food areas in a cleaning materials locker so they cannot contaminate food, equipment, utensils, linens, and single-service and single-use articles.
|
|
|
Item No.:
19
|
|
Site:
Housekeeping-Stewardess Lockers
|
|
Violation:
Water bottles, coffee packs, coffee creamers, and tea bags were stored adjacent to, on and above cleaning and sanitizing chemicals used for housekeeping, clean linens, clean cups, and clean glasses. The staff explained that there were about 28 lockers on the ship, all with the same setting.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck. Do not store foods in locker rooms or areas not finished in accordance with 7.7.4 and 7.7.5 for food storage areas. Protect food from contamination that may result from a physical, chemical, biological origin.
|
|
|
Item No.:
28
|
|
Site:
Housekeeping-Stewardess Lockers
|
|
Violation:
Clean linens, clean cups, and clean glasses were stored adjacent to, on and above cleaning and sanitizing chemicals used for housekeeping, water bottles, coffee packs, coffee creamers, and tea bags, The staff explained that there were about 28 lockers on the ship, all with the same setting.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
|
|
|
Item No.:
36
|
|
Site:
Food Service General-Lighting
|
|
Violation:
In the pantries and the galleys, the light intensity behind and around many pieces of counter-mounted and deck-mounted equipment was less than 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
08
|
|
Site:
Food Service General-
|
|
Violation:
The nonpotable chilled water lines connected to the back of the ice machines in food areas throughout the ship were not uniquely identified.
|
|
Recommendation:
Uniquely identify all chilled water and refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
|
|
|
Item No.:
21
|
|
Site:
Buffet-All Restaurant Large Buffet Counters
|
|
Violation:
The undercounter technical compartments beneath the large buffet counters in all restaurants were difficult to clean due to many cable bundles on perforated panels, gaps around panels and crevices throughout the large open technical compartments. Most were clean, but the construction made cleaning very difficult.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Food Service General-All Galleys and Palms Buffet
|
|
Violation:
The grease pan housing for all Lang flat-top grills and range tops were long, wide, channels of only 25 mm height, which made cleaning inside very difficult. Some had large open voids inside, both above and below the housing section which was also difficult to access and clean.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Close the open voids.
|
|
|
Item No.:
21
|
|
Site:
Galley-Deck 10 Galley
|
|
Violation:
There were gaps where pipes penetrated the starboard end of the undercounter warming cabinet beneath the bain marie. There were also difficult to clean gaps and open voids at the port end of this technical compartment at the side and lower panels.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Close the gaps and open voids.
|
|
|
Item No.:
21
|
|
Site:
Galley-Deck 10 Galley
|
|
Violation:
There was a gap where the port end of the bain marie counter joined the stainless steel bulkhead panel.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Close the gap.
|
|
|
Item No.:
29
|
|
Site:
Galley-Deck 10 Galley
|
|
Violation:
The two automated handwash station faucets reached only 87-90°F when adjusted to the fullest hot temperature at the faucet. Staff corrected this during the inspection.
|
|
Recommendation:
Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
|
|
|
Item No.:
16
|
|
Site:
Galley-Deck 10 Galley
|
|
Violation:
The posted time control plan did not specify set-up or discard times for foods on time control. Set-up was stated to be 30 minutes prior to published opening hours each day.
|
|
Recommendation:
Identify standard times for each meal service, and for port, sea or disembarkation days. On days when this changes, a small posting can be placed near the time control plan. Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan includes set-up and discard times for each outlet.
|
|
|
Item No.:
16
|
|
Site:
Galley-Deck 10 Galley
|
|
Violation:
The hot milk and hot porridge in separate chafing dishes at the counter in the hot galley were not identified as being on time control. Staff stated these were always on time control and time between service set-up and closing could be greater than 4 hours.
|
|
Recommendation:
If time only-rather than time in conjunction with temperature-is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours).
|
|
|
Item No.:
36
|
|
Site:
Galley-Deck 10 Galley
|
|
Violation:
The light intensity at the clean pot rack was less than 220 lux.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-Passenger and Crew Buffets
|
|
Violation:
There were no time control plans posted at any of the passenger or crew buffets. The plans were posted in the galleys.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used.
|
|
|
Item No.:
36
|
|
Site:
Galley-Deck 10 Galley - Wine Cellar
|
|
Violation:
The light intensity along the beverage counter was less than 220 lux.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
21
|
|
Site:
Galley-Deck 10 Galley - Wine Cellar
|
|
Violation:
The profile strip between the toaster counter and the bulkhead was loose, creating a difficult to clean gap.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Secure the profile strip.
|
|
|
Item No.:
36
|
|
Site:
Food Service General-Waiter Stations - All Restaurants
|
|
Violation:
The light intensity over nearly all restaurant dining room waiter stations could not be raised to 220 lux.
|
|
Recommendation:
In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Palms Buffet
|
|
Violation:
There was a hole on the deckhead at the starboard/aft corner on the workers side. The staff stated that a light fixture was once installed on the place.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Close the hole.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Palms Buffet
|
|
Violation:
There was a large hole at the center buffet counter near the flat grill where a deck to buffet foundation tile was missing.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Replace the foundation tile.
|
|
|
Item No.:
36
|
|
Site:
Galley-Deck 7 Palms Galley
|
|
Violation:
The light intensity behind and around reach-in refrigerator #51/52 was less than 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
33
|
|
Site:
Bar-Palms Cafe Bar
|
|
Violation:
The deck at the front and back bar counter foundation/deck juncture was not coved.
|
|
Recommendation:
Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
|
|
|
Item No.:
21
|
|
Site:
Bar-Palms Cafe Bar
|
|
Violation:
There were difficult to clean gaps at the forward end of the front counter where pipes penetrated the bulkhead. Additionally, there were open voids throughout the front bar undercounter technical compartment, and especially at the counter foundation.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Close the gaps and voids.
|
|
|
Item No.:
39
|
|
Site:
Bar-Palms Cafe Bar
|
|
Violation:
There were over 40 live ants crawling along the top of the deck foundation tile of the front bar counter. The ants crawled from a gap at the forward end to a void inside the center technical compartment. The ants were also entering and leaving from one of the voids in the lower panel, just above the deck.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
36
|
|
Site:
Pantry-Morning Light Pub
|
|
Violation:
The light intensity over the counter corner where the liquors were stored was less than 220 lux.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
16
|
|
Site:
Room Service-Consumer Advisory
|
|
Violation:
There was no consumer advisory on the room service menu indicating that consuming raw or undercooked animal-derived foods may increase the risk for foodborne illness, especially to consumers with certain medical conditions. The menu included cold-smoked salmon appetizers and gravlax.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that disclosure is on a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
|
|
|
Item No.:
21
|
|
Site:
Food Service General-All Food Area Counter Equipment
|
|
Violation:
Power cables and water lines to the hot and cold drink dispensers and other fixed equipment like ovens and toasters were draped on the counters making cleaning difficult.
|
|
Recommendation:
Shorten or elevate cables and water lines so they hang over the counter top and make cleaning beneath equipment easy.
|
|
|
Item No.:
16
|
|
Site:
Dining Room-Consumer Advisory
|
|
Violation:
There was no consumer advisory on the Ballindalloch Restaurant menu indicating that consuming raw or undercooked animal-derived foods may increase the risk for foodborne illness, especially to consumers with certain medical conditions. The menu included animal-derived foods such as eggs, beef, and lamb that could be served undercooked.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that disclosure is on a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Ballindalloch Restaurant
|
|
Violation:
The light intensity over the forward end of the port and starboard dining room buffets was less than 220 lux.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Ballindalloch Restaurant
|
|
Violation:
The seams between the deckhead panels over the aft bulkhead buffet on the starboard side of the dining room were soiled with dust.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
27
|
|
Site:
Galley-Hot Galley
|
|
Violation:
The grease pan housings for the two previously cleaned flat-top grills were heavily soiled with grease and food residue.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
20
|
|
Site:
Galley-Hot Galley
|
|
Violation:
The Hobart oven in the center galley was out of order and had been in disrepair for months, according to the staff.
|
|
Recommendation:
Food contact equipment must be maintained in good repair and proper adjustment. Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines. Repair, replace, or remove the oven.
|
|
|
Item No.:
27
|
|
Site:
Galley-Pastry
|
|
Violation:
The refrigerant pipe insulation in the undercounter technical compartment for the ice cream chest freezers in the dish-up section was wet and heavily soiled with mold.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
20
|
|
Site:
Preparation Room-Deck 5
|
|
Violation:
The in-use dough sheeter belt had holes in different sections along the middle of the belt, and there were long fibers protruding from the belt in areas throughout the length in the center and edges.
|
|
Recommendation:
Replace the worn dough sheeter belt.
|
|
|
Item No.:
33
|
|
Site:
Room Service-
|
|
Violation:
Several of the deckhead panels were separating at joints with other panels and at the ends of the profile strips, leaving gaps that were difficult to clean.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Close the gaps.
|
|
|
Item No.:
22
|
|
Site:
Room Service-
|
|
Violation:
There was inadequate clean storage racks for air-drying cleaned items and staff had 5 dishware racks of cleaned items on the center food preparation counter. No food was being prepared at the time of the inspection, but the food counter had no drainage and there were no deck drains or gutterways near to that center counter.
|
|
Recommendation:
Use a portable clean rack and place over an area with gutterways for drainage. Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Crew Mess - Beverage Station
|
|
Violation:
The light intensity over the beverage station counter was less than 220 lux.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
34
|
|
Site:
Provisions-Meat Thawing Box 13A
|
|
Violation:
There were two deckhead water leaks inside this walk-in refrigerator. The deckhead was clearly deformed and sagging down where these water leaks at the panel joints were located. No food items appeared to be impacted.
|
|
Recommendation:
Ensure the plumbing system in the food area is maintained in good repair.
|
|
|
Item No.:
17
|
|
Site:
Provisions-Fish Walk-in Refrigerator
|
|
Violation:
There was no parasite destruction record for the variety of ready-to-eat pickled herring and roll mop herring available onboard.
|
|
Recommendation:
If raw, raw-marinated, partially cooked, or marinated partially cooked fish are served in ready-to-eat form and if the fish are frozen by a supplier, a written letter from the supplier which specifies the fish species involved and both the temperature to which the fish was frozen and the total time period at that temperature. If the supplier provides any of the same species to the vessel in a fresh state, ensure there is a designation on the outer packaging for the parasite-free fish.
|
|
|
Item No.:
38
|
|
Site:
Preparation Room-
|
|
Violation:
Two potato peeling machines were wrapped in plastic film with a sign stating not in use. Staff stated they were no longer needed or used.
|
|
Recommendation:
Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
|
|
|
Item No.:
33
|
|
Site:
Preparation Room-
|
|
Violation:
The deckhead profiles throughout this room were damaged and not easy to clean where they attached to deckhead panels. The deck tiles had recessed grout and some were cracked or broken.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Pantry-Observation Lounge
|
|
Violation:
The deckhead profile over the ice machine was loose, creating a difficult to clean gap.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Secure the profile.
|
|
|
Item No.:
21
|
|
Site:
Bar-Marquee Bar
|
|
Violation:
There were open voids where panels were missing in the undercounter technical compartment throughout the length of the front bar.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Close the voids.
|
|