Item No.:
40
|
|
Site:
Integrated Pest Management-Garbage Handling Area
|
|
Violation:
There was no documentation indicating the garbage handling areas were inspected at least weekly for the presence of insects, rodents, and other pests.
|
|
Recommendation:
Inspect the garbage handling areas of the vessel at least weekly for the presence of insects, rodents, and other pests. Maintain the results of these inspections in a log.
|
|
|
Item No.:
43
|
|
Site:
Ventilation-Air Handling Units
|
|
Violation:
Technical water was used to clean the air handling units.
|
|
Recommendation:
Use only potable water for cleaning HVAC distribution systems.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Striping
|
|
Violation:
The distillate lines from the two evaporators and the permeate lines from the reverse osmosis system were not striped to the production halogen injection point in accordance with ISO 14726 standards (blue/gray/blue).
|
|
Recommendation:
Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
The backflow prevention device on the faucet of the spa deck 9 private tub was difficult to access and required the use of several tools.
|
|
Recommendation:
Ensure backflow prevention devices and air gaps are accessible for inspection, service, and maintenance.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Filter Housing
|
|
Violation:
According to the staff, the filter housing for the RWFs were cleaned, rinsed, and disinfected, but there was no documentation of the disinfectant concentration or contact time.
|
|
Recommendation:
Clean, rinse, and disinfect the filter housing before the new filter media is placed in it. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Hair and Lint Strainers
|
|
Violation:
According to the staff, the hair and lint strainers and the hair and lint strainer housings for the RWFs were cleaned, rinsed, and disinfected, but there was no documentation of the frequency of cleaning, disinfectant concentration, or contact time.
|
|
Recommendation:
Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Fecal and Vomit Accident Plan
|
|
Violation:
The fecal and vomit accident plan did not include how to clean up vomit accidents and did not include the correct contact times for loose stool accidents.
|
|
Recommendation:
Ensure a fecal and vomit accident response procedure that meets or exceeds the procedure provided in Annex 13.8 is available for review during inspections.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Sample Lines
|
|
Violation:
The sample lines for the analyzer probes for the RWFs were located after the compensation tank.
|
|
Recommendation:
Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Deck 8 Whirlpools
|
|
Violation:
There were three suction fittings for the therapy pumps less than three feet apart on both of the deck 8 whirlpools. The fittings had ASME A112.19.8 compliant covers, but no automatic pump shut-off systems or safety vacuum release systems were installed.
|
|
Recommendation:
For RWFs with suction fittings and a single blockable drain or multiple drains (less than 3 feet apart), provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a safety vacuum release system or automatic pump shut-off system.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Safety Signs
|
|
Violation:
The safety signs for the deck 5 and deck 8 swimming pools did not have the bather load numbers. Also, the whirlpool safety signs did not meet the requirements of the 2011 VSP Operations Manual.
|
|
Recommendation:
Provide safety signs for all RWFs, except for baby-only water facilities. Ensure the signs, at a minimum, include the following words: (1) do not use these facilities if you are experiencing diarrhea, vomiting, or fever; (2) no children in diapers or who are not toilet trained; (3) shower before entering the facility; and (4) bather load #. In addition to the safety sign requirements in section 6.7.1.1.1, install a sign at each whirlpool spa and spa pool entrance listing precautions and risks associated with the use of these facilities. Include, at a minimum, cautions against use by the following: (1) individuals who are immunocompromised; (2) individuals on medication or who have underlying medical conditions such as cardiovascular disease, diabetes, or high or low blood pressure; and (3) pregnant women, elderly persons, and children. Additionally, caution against exceeding 15 minutes of exposure.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Outbreak Prevention and Response Plan (OPRP)
|
|
Violation:
The OPRP did not include procedures for informing passengers and crew of an outbreak or procedures for returning the vessel to normal operating conditions after an outbreak.
|
|
Recommendation:
Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (4) Procedures for informing passengers and crew members of the outbreak. Ensure this section also includes procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage; (5) Procedures for returning the vessel to normal operating conditions after an outbreak.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Deck 3 Mid Ship Female Crew Toilet Room
|
|
Violation:
There was no sign advising users to wash their hands. Also, there was no sign posted advising users of the toilet room to use a hand towel, paper towel, or tissue to open the door. The exit for this crew public toilet room was not hands free.
|
|
Recommendation:
Provide the passenger and crew public toilets with a handwashing station that includes: (4) A sign advising users to wash hands. Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free. Equip passenger and crew public toilet facilities so persons exiting the toilet room are not required to touch the door handle with bare hands. Where toilet stalls include handwashing facilities, ensure the bare-hands-free contact begins in the toilet stall. Ensure that toilet facilities with multiple exits, such as spa dressing rooms, have bare-hands-free contact at each exit.
|
|
|
Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Surveillance Log
|
|
Violation:
The AGE surveillance log did not include the case identification number, the time passengers or crew reported to medical, passenger meal seating, specimen requested, or a specific place to record body temperature. Also, the items on the AGE surveillance log were not in the exact order as required in Annex 13.2.2 of the 2011 VSP Operations Manual. According to the staff, the definition for a reportable case of AGE for episodes of diarrhea did not include what was above normal for the individual.
|
|
Recommendation:
Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (2) time of the first medical visit or report to staff of illness; (3) case identification number; (10) meal seating information; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (d) recorded temperature, and specimen requested. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure a reportable case of AGE is a case reported to the master of the vessel, the medical staff, or other designated staff by a passenger or a crew member and meets the case definition based on the following symptoms: (1) Diarrhea (three or more episodes of loose stools in a 24 hour period or what is above normal for the individual. See section 4.1.2.1.3, illness symptoms).
|
|
|
Item No.:
16
|
|
Site:
Food Service General-Consumer Advisory
|
|
Violation:
There were prepared foods containing eggs, steak, veal, and fish that could be cooked to order on the breakfast, lunch, and dinner menus. There was a consumer advisory statement at the bottom of each menu, but there was no asterisk at these food items on the menu.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that disclosure is made by one of the two following methods: (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-Time Control Plans
|
|
Violation:
The posted time control plans in all of the food preparation areas did not include the set-up times.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet.
|
|
|
Item No.:
20
|
|
Site:
Galley-The Colonnade
|
|
Violation:
In the preparation galley, the plastic panel in the upper interior of the microwave was loose and not properly secured. The panel was removed and the microwave was placed out of service.
|
|
Recommendation:
Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines.
|
|
|
Item No.:
20
|
|
Site:
Food Service General-Temperature-Measuring Devices
|
|
Violation:
Food employees responsible for measuring the temperature of thin foods were not equipped with tip-sensitive temperature-measuring devices.
|
|
Recommendation:
Use tip-sensitive temperature-measuring devices, such as a thermocouple or thermistor, for measuring thin food products.
|
|
|
Item No.:
40
|
|
Site:
Galley-The Colonnade
|
|
Violation:
The swinging door leading from the galley to the open deck seating area was fully open upon the inspector's arrival to the area. The staff closed the door and upon further inspection a few hours later, the door remained closed. Also, when the door was closed, there was a three-inch gap between the door and the door frame. No flies were observed in this area.
|
|
Recommendation:
Protect entry points where pests may enter the food areas.
|
|
|
Item No.:
33
|
|
Site:
Galley-The Colonnade
|
|
Violation:
The swinging door leading from the galley to the open deck seating area was damaged, preventing the door from closing completely and leaving a three-inch gap between the door and door frame.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
36
|
|
Site:
Food Service General-Light Intensity
|
|
Violation:
During normal operation, the light intensity was less than 110 lux at some of the handwashing stations in several of the bars.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at handwashing stations in bars.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Bonded Store
|
|
Violation:
Many of the round stainless steel deckhead supports were loose, creating gaps.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
25
|
|
Site:
Preparation Room-
|
|
Violation:
A wiping cloth was on the preparation counter. The cloth was placed in the chemical sanitizing solution.
|
|
Recommendation:
Restrict wiping cloths to the following: (2) Cloths used for wiping food spills are dry and used for wiping food spills from tableware and single service articles or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment.
|
|
|
Item No.:
19
|
|
Site:
Galley-Cold Galley
|
|
Violation:
In the walk-in refrigerator, previously rinsed mixed fresh fruits contained the manufacturer's label.
|
|
Recommendation:
Thoroughly rinse raw fruits and vegetables in water to remove soil and other contaminants before being cut, combined with other ingredients, cooked, served, or offered for human consumption in ready-to-eat form.
|
|
|
Item No.:
27
|
|
Site:
Galley-Port Cold Pantry
|
|
Violation:
The shelves above the utility sink and the preparation counter were heavily soiled with dust. This was corrected.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Room Service-Port Dishwash Area
|
|
Violation:
Some of the room service trays in the clean utensil storage area were soiled.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
26
|
|
Site:
Room Service-Port Dishwash Area
|
|
Violation:
In the china locker, some of the previously cleaned dishes were soiled. These dishes were removed to the dishwash area.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
28
|
|
Site:
Room Service-Port Dishwash Area
|
|
Violation:
In the china locker, numerous previously cleaned dishes were stacked and stored wet. The shelves below these dishes were wet. In the silver locker, numerous previously cleaned candlesticks, vases, and stacked butter covers were stored wet. The shelves below these dishes were wet. Upon re-inspection, the items and shelving in the china locker were dry.
|
|
Recommendation:
Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
|
|
|
Item No.:
36
|
|
Site:
Galley-Starboard Waiter Station
|
|
Violation:
The light intensity was below 110 lux behind the counter-mounted water dispensing unit.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
28
|
|
Site:
Galley-Starboard Equipment Storage
|
|
Violation:
There were two boxes of clean utensils stored on the deck. The boxes were moved to a shelf.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (3) at least 150 millimeters (6 inches) above the deck.
|
|
|
Item No.:
24
|
|
Site:
Galley-Starboard Potwash
|
|
Violation:
A crew member was observed at the in-use main potwash three compartment sink manually sanitizing at least four pans and bowls for less than seven seconds in the chlorine sanitizing compartment. The equipment was then stored on a drying rack. This was discussed with the supervisor; however the items were not re-sanitized and no further action occurred.
|
|
Recommendation:
Ensure a chemical sanitizer is used in accordance with the EPA-approved manufacturer?s label use instructions at a minimum temperature of 24°C (75°F) with an exposure time of 7 seconds for a chlorine solution and 30 seconds for other chemical sanitizers.
|
|
|
Item No.:
30
|
|
Site:
Galley-Toilet Room
|
|
Violation:
There was no sign in the toilet room for galley personnel stating 'wash hands after using toilet.'
|
|
Recommendation:
Ensure signs are conspicuously posted on the bulkhead adjacent to the door of the toilet, reading "WASH HANDS AFTER USING TOILET " in a language that the food employees understand.
|
|
|
Item No.:
27
|
|
Site:
Buffet-Heat Lamps
|
|
Violation:
The heat lamps above the carving station were soiled. The carving station was not in use at the time of the inspection.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
19
|
|
Site:
Buffet-
|
|
Violation:
Three containers of bread were out for service at the cold buffet line and were not equipped with self-closing hinged lids or under a sneeze guard. The buffet was open during the time of the inspection.
|
|
Recommendation:
Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means.
|
|
|
Item No.:
30
|
|
Site:
Galley-Outside Toilet Rooms
|
|
Violation:
There were no signs in the toilet rooms stating 'wash hands after using toilet'. These toilet rooms were used by galley workers.
|
|
Recommendation:
Ensure signs are conspicuously posted on the bulkhead adjacent to the door of the toilet, reading "WASH HANDS AFTER USING TOILET " in a language that the food employees understand.
|
|
|
Item No.:
40
|
|
Site:
Pantry-Patio Bar
|
|
Violation:
The door to the pantry was propped open during the first inspection of the area. This bar was on an open deck, but was not open for service. A crew member was instructed by the inspector to close the door. After further discussion with the manager, the door was closed and no flies were observed in this area.
|
|
Recommendation:
Protect entry points where pests may enter the food areas.
|
|
|
Item No.:
16
|
|
Site:
Pantry-Patio Grill
|
|
Violation:
The time control plan did not describe when the potentially hazardous food was taken from temperature control in the galley to placement on time control in the pantry.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
19
|
|
Site:
Pantry-Patio Grill
|
|
Violation:
A plastic container used for dessert items was not equipped with a self-closing hinged lid. No food items were stored in this container at the time of the inspection.
|
|
Recommendation:
Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means.
|
|
|
Item No.:
25
|
|
Site:
Bar-Coffee Bar
|
|
Violation:
A wet wiping cloth was on the counter. The cloth was placed in the chemical sanitizing solution.
|
|
Recommendation:
Restrict wiping cloths to the following: (2) Cloths used for wiping food spills are dry and used for wiping food spills from tableware and single service articles or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment.
|
|
|
Item No.:
16
|
|
Site:
Bar-Coffee Bar
|
|
Violation:
The milk compartment of the coffee machine was physically labeled for time control, but was not listed in the time control plan.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such).
|
|
|
Item No.:
19
|
|
Site:
Galley-Port Cold Pantry
|
|
Violation:
On the preparation counter, a container of previously rinsed nectarines contained the manufacturer's label.
|
|
Recommendation:
Thoroughly rinse raw fruits and vegetables in water to remove soil and other contaminants before being cut, combined with other ingredients, cooked, served, or offered for human consumption in ready-to-eat form.
|
|