Item No.:
16
|
|
Site:
Other-Time Control Plans for Milk in Coffee Machines
|
|
Violation:
In the Executive Lounge, Concierge Lounge and Grand Bar, the time control plans for the milk in the coffee machines were not posted.
|
|
Recommendation:
Post a time control plan at each outlet where time control is used.
|
|
|
Item No.:
27
|
|
Site:
Other-Concierge Lounge
|
|
Violation:
The drain and adjacent wall in the technical space below the coffee machine was soiled. This was corrected.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
21
|
|
Site:
Other-Concierge Lounge
|
|
Violation:
There was a gap at the front, bottom of the technical space below the coffee machine.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
33
|
|
Site:
Other-Concierge Lounge
|
|
Violation:
There was no coving at the cabinet/deck juncture for the small storage cabinet across from the service counter. This cabinet was used to store beverages.
|
|
Recommendation:
Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
|
|
|
Item No.:
16
|
|
Site:
Preparation Room-Time Control Plan
|
|
Violation:
Two cold holding trolleys were labeled for time control, but there was no plan posted in this outlet. According to the staff, the food in the trolleys is transported to the specialty galleys.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used.
|
|
|
Item No.:
16
|
|
Site:
Buffet-Staff/Officers Mess
|
|
Violation:
The time control plan indicated the service hours that food was on time control. However, milk in the coffee machine and in an undercounter refrigerator on the beverage line were on time control with 4-hours discard labels outside of the regular meal service times. Therefore, the plan did not completely reflect the operations.
|
|
Recommendation:
Ensure the written time control plan reflects the operations.
|
|
|
Item No.:
16
|
|
Site:
Galley-Time Control Plan
|
|
Violation:
The time control plan indicated the service hours that food was on time control. However, pans of rice were prepared and held on time control with 4-hour discard labels outside of these service hours. Therefore, the plan did not completely reflect the operations.
|
|
Recommendation:
Ensure the written time control plan reflects the operations.
|
|
|
Item No.:
21
|
|
Site:
Galley-
|
|
Violation:
The stainless steel strip directly below the cooking surface on the flat grill was bent on the front and right side, creating gaps. This was corrected.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
08
|
|
Site:
Galley-Hood Cleaning Cabinet
|
|
Violation:
There was a continuous leak from the atmospheric vent on the backflow prevention device. The device was replaced.
|
|
Recommendation:
Maintain backflow prevention devices in good repair.
|
|
|
Item No.:
27
|
|
Site:
Buffet-
|
|
Violation:
The insulation for the chill line in the technical space for undercounter refrigerator 3 was soiled and wet. This was corrected.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Beverage Line
|
|
Violation:
The light intensity on both sides of the ice/water dispenser was less than 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
20
|
|
Site:
Food Service General-Tip-sensitive Temperature-measuring Device
|
|
Violation:
Several of the supervisory chefs had tip-sensitive temperature-measuring devices, but not all of the cooks who measured thin foods. According to the staff, additional tip-sensitive temperature-measuring devices had been ordered and would be distributed to the rest of the cooks.
|
|
Recommendation:
Ensure food temperature-measuring devices are provided and readily accessible for use in ensuring attainment and maintenance of food temperatures. Use tip-sensitive temperature-measuring devices, such as a thermocouple or thermistor, for measuring thin food products.
|
|
|
Item No.:
24
|
|
Site:
Galley-Dishwash Area
|
|
Violation:
There was no spray from the final sanitizing rinse on the conveyor warewash machine. A breaker for the final rinse pump had failed, and the pump was not working. In addition, the visual alarm on the warewash panel was indicating an error. When the error code was checked, it indicated that the final rinse spray was not working. The final rinse sanitizing spray was checked at 0700 at the beginning of operations, and the malfunctioning spray was discovered at approximately 1000. It was not clear how long the spray had been malfunctioning. The pump was replaced and a sufficient final sanitizing temperature was achieved. According to the staff, the items washed during the morning would be sent through the warewash machine again.
|
|
Recommendation:
Ensure the final sanitizing rinse spray is functioning at all times when the warewash machine is in operation.
|
|
|
Item No.:
13
|
|
Site:
Galley-Dishwash Area
|
|
Violation:
The visual alarm on the warewash panel was indicating an error, but the crew members working in the area did not respond to the alarm. When the error code was checked, it indicated that the final rinse spray was not working. The alarm was turned off only after the malfunctioning spray was discovered by the inspector.
|
|
Recommendation:
Ensure crew members are properly sanitizing cleaned multiuse equipment and utensils before they are reused. Ensure crew members respond when the machine alarms.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-Consumer Advisories
|
|
Violation:
There were no consumer advisories on the menus for the restaurants. The menus are distributed by the corporate office and could not be changed on the vessel. According to the staff, until the menus were changed, consumer advisories are posted at the entrances to the restaurants. In addition, there were advisories posted in the passenger buffet, but there were no signs indicating what animal-derived foods could be served raw or undercooked.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., "oysters on the half-shell," "hamburgers," "steaks," or "eggs"); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order OR (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
|
|
|
Item No.:
21
|
|
Site:
Dining Room-Main - Coffee Station
|
|
Violation:
There was a seam along the top of the frame for the drawer for the used coffee grounds below the coffee machine.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
08
|
|
Site:
Galley-Terrace Cafe - Hood Cleaning Cabinet
|
|
Violation:
There was a continuous leak from the atmospheric vent on the backflow prevention device.
|
|
Recommendation:
Maintain backflow prevention devices in good repair.
|
|
|
Item No.:
16
|
|
Site:
Buffet-Terrace Cafe - Time Control Plan
|
|
Violation:
The time control plan stated that the milk in the starboard WMF coffee machine was available 24 hours and the milk in the port WMF coffee machine was available breakfast service through dinner service. There was an additional statement that all other milk was on time control. From the plan, it was not clear if the milk in the coffee machines was on time control, if it required 4-hour discard labels, or when it would be discarded. The milk at the beverage stations had 4-hour discard labels.
|
|
Recommendation:
Ensure the written time control plan clearly indicates when milk is on time control, if 4-hour discard labels are required, and when the milk should be discarded.
|
|
|
Item No.:
16
|
|
Site:
Buffet-Terrace Cafe - Time Control Plan
|
|
Violation:
The two counter top milk dispensers on both port and starboard beverage lines were on time control, but they were not labeled for time control and were not listed on the time control plan. The milk inside the dispensers had four-hour discard labels.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Ensure plans list refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such).
|
|
|
Item No.:
13
|
|
Site:
Other-Bon Appétit Culinary Center
|
|
Violation:
The vessel had a variance for a class where passengers prepare food. A requirement of the variance was to keep the variance and approval letter from VSP onboard the vessel. The variance and approval letter could not be located. Forms with information about health and safety procedures signed by the participating passengers were available. The back of these forms had additional information about the classes and procedures, but no one knew if this was the actual variance.
|
|
Recommendation:
Maintain the variance and the VSP approval letter onboard the vessel and make it available for review during inspections.
|
|
|
Item No.:
08
|
|
Site:
Food Service General-Chilled Water Lines
|
|
Violation:
The chilled water lines to the ice machines in the galleys and pantries were not uniquely identified.
|
|
Recommendation:
Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
|
|
|
Item No.:
36
|
|
Site:
Bar-Martini and Grand
|
|
Violation:
The light intensity at the handwashing stations was not at least 110 lux during operations.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at handwashing stations in bars.
|
|
|
Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Surveillance Log
|
|
Violation:
The AGE surveillance log did not have the required information in the exact order as Annex 13.2.2 of the 2011 VSP Operations Manual.
|
|
Recommendation:
Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Date of the first medical visit or report to staff of illness; (2) time of the first medical visit or report to staff of illness; (3) case identification number; (4) person's name; (5) person's age; (6) person's sex; (7) designation as passenger or crew member; (8) crew member position or job on the vessel, if applicable; (9) cabin number; (10) meal seating information; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24-hour period; (b) number of episodes of vomiting in a 24-hour period; (c) bloody stools; (d) recorded temperature; (e) abdominal cramps; (f) headaches; (g) muscle aches; (14) entry (yes/no) for whether this was a reportable case; (15) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (16) presence of underlying medical conditions that may affect interpretation of AGE. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Microbiological Testing
|
|
Violation:
The vessel did not have a color comparator for analyzing results of the potable water microbiological testing.
|
|
Recommendation:
If water samples are collected and analyzed by the vessel for the presence of E. coli, analyze the samples using a method accepted in Standard Methods for the Examination of Water and Wastewater. Ensure test kits, incubators, and associated equipment are operated and maintained in accordance with the manufacturers' specifications.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross-Connection Control Program
|
|
Violation:
On the list of reduced pressure backflow prevention assemblies, the physical location of several of these assemblies was indicated, but the plumbing system component was not. This was written on the previous inspection. This was corrected.
|
|
Recommendation:
Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross-Connection Control Program
|
|
Violation:
The testing records for the reduced pressure backflow prevention assemblies indicated the six assemblies in the bunker stations were tested in January 2012 but no pressure differentials were recorded. The staff explained that the tests were attempted but not performed. In addition, for all other assemblies tested in January 2012, there was no notation if the assemblies passed or failed the tests. Furthermore, the tests appeared to be incomplete since there were no pressure differentials recorded for the relief valve test as stated in the manufacturer's instructions for the Watts 909 series.
|
|
Recommendation:
Inspect and test backflow prevention devices requiring testing with a test kit after installation and at least annually. Maintain the test results showing the pressure differences on both sides of the valves for each device.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Bridge Restroom
|
|
Violation:
There were no paper towels at the handwash station.
|
|
Recommendation:
Provide the passenger and crew public toilets with a handwashing station that includes: (1) Hot and cold running water; (2) Soap; (3) A method to dry hands; (4) A sign advising users to wash hands.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Public Toilets
|
|
Violation:
Passenger and crew public toilet rooms did not have signs advising users to wash hands. In addition, there were no signs advising users to use hand towel, paper towel, or tissue to open the door when exiting.
|
|
Recommendation:
Provide the passenger and crew public toilets with a handwashing station that includes a sign advising users to wash hands. Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Fecal and Vomit Accident Plan
|
|
Violation:
The fecal accident plan included conflicting information on free halogen concentration and contact times for responding to loose stool accidents. The plan included pages with the 2005 and 2011 VSP Operations Manuals requirements for the inactivation of Cryptosporidium. In addition, the ship's electronic management system had forms for the documentation of fecal and vomit accidents with the 2005 VSP Operations Manual requirements.
|
|
Recommendation:
Ensure a fecal and vomit accident response procedure that meets or exceeds the procedure provided in Annex 13.8 is available for review during inspections.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Turnover Rates
|
|
Violation:
The turnover rate was not calculated for each recreational water facility.
|
|
Recommendation:
Design recirculation systems and equipment, including chemical control equipment, UV disinfection systems, filter, and pumps to maintain adequate water chemistry control while operating at the following minimum turnover rates: (1) swimming pool (VSP 2005 Construction Guidelines or earlier): 6 hours; (2) swimming pool (VSP 2011 Construction Guidelines or later): 4 hours; (3) children's pool: 0.5 hours; (4) wading pool: 1 hour; (5) whirlpool spa: 0.5 hours; (6) spa pool: 2 hours; (7) interactive RWF or activity pool less than 610 millimeters (24 inches) deep: 1 hour; (8) interactive RWF or activity pool greater than 610 millimeters (24 inches) deep: 2 hours; and (9) baby-only water facility: 0.5 hours. Ensure an RWF slide that is combined with a pool has a turnover rate that matches the rate for the pool.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Whirlpool Analyzer Chart Recorders
|
|
Violation:
The sample lines for the whirlpool analyzer probes were located after the compensation tanks.
|
|
Recommendation:
Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Safety Signs
|
|
Violation:
The safety signs posted at the pool and whirlpools did not contain all of the required information.
|
|
Recommendation:
Ensure the signs, at a minimum, include the following words: (1) do not use these facilities if you are experiencing diarrhea, vomiting, or fever; (2) no children in diapers or who are not toilet trained; (3) shower before entering the facility; and (4) bather load #. In addition to the safety sign requirements in section 6.7.1.1.1, install a sign at each whirlpool spa and spa pool entrance listing precautions and risks associated with the use of these facilities. Include, at a minimum, cautions against use by the following: (1) individuals who are immunocompromised; (2) individuals on medication or who have underlying medical conditions such as cardiovascular disease, diabetes, or high or low blood pressure; and (3) pregnant women, elderly persons, and children. Additionally, caution against exceeding 15 minutes of exposure.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Water Testing
|
|
Violation:
There was no test kit to test the total chlorine/bromine and alkalinity.
|
|
Recommendation:
Ensure a test kit is available for testing water quality parameters, including free and total halogen levels (chlorine and bromine, where applicable), pH, and total alkalinity.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Outbreak Prevention and Response Plan
|
|
Violation:
The outbreak prevention and response plan did not include procedures for informing current and embarking passengers and crew members of an outbreak or procedures for returning the vessel to normal operating conditions after an outbreak. In addition, the contact times for the disinfectant products were not specified.
|
|
Recommendation:
Include the following in the written OPRP: disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times; procedures for informing passengers and crew members of the outbreak including procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage; and procedures for returning the vessel to normal operating conditions after an outbreak.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Loading Inspections
|
|
Violation:
It was unclear from the records if nonfood items were inspected during loading inspections.
|
|
Recommendation:
Routinely inspect incoming shipments of food and all other supplies for evidence of insects, rodents, and other pests. Maintain a record of these inspections onboard the vessel and make the record available for review during inspections.
|
|
|
Item No.:
43
|
|
Site:
Ventilation-Deck 11 Forward/Starboard
|
|
Violation:
There was an accumulation of about 1 inch of water in the condensation collection pan of ventilation unit AC11.2.01/PT1. It was unclear if the condensation collection pan was self-draining.
|
|
Recommendation:
Ensure condensation collection pans are self-draining.
|
|