Item No.:
08
|
|
Site:
Food Service General-Ice Machine Chilled Water
|
|
Violation:
The flexible and fixed chilled water lines connected to the rear exterior panel on the ice machines throughout the ship did not have any unique identification that these lines were chilled water.
|
|
Recommendation:
Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
|
|
|
Item No.:
36
|
|
Site:
Galley-Room Service Area
|
|
Violation:
The artificial light level behind and beside the two (side-by-side) ice machines was below the minimum 110 lux (10 foot candles) required.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
39
|
|
Site:
Galley-Room Service Area
|
|
Violation:
One live fruit fly was observed flying around the ice machine near to the port hole window.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
26
|
|
Site:
Galley-Cold Pantry
|
|
Violation:
Inside the knife locker and stored as clean were a knife, which was soiled with food debris along the blade, and a hand mixer which had accumulated food debris wedged into the food-contact area around and below the blade.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch. Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
18
|
|
Site:
Galley-Cold Pantry
|
|
Violation:
There were 7 unopened plastic pint containers of fresh blackberries stacked in the cold basin and surrounded by open serving containers filled with individual berries which were being spooned onto serving dishes and stacked for waiter pick-up at the cold line. It was unclear if these packaged blackberries were going to be washed before refilling the bowls in the basin or simply added unwashed. It was also unclear if there was an initial washing made with the other berries (raspberry, blueberry) was actually performed before transfer to their bulk serving bowls and later plating.
|
|
Recommendation:
Protect food from cross-contamination or other sources of contamination by the following methods: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food so that products do not physically touch and so that one product does not drip into another. (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry?except when combined as ingredients?during storage, preparation, holding, and display by using separate equipment for each type, or by arranging each type of food in equipment so that cross-contamination of one type with another is prevented, or by preparing each type of food at different times or in separate areas. (3) Cleaning and sanitizing equipment and utensils. (4) Storing the food in packages, covered containers, or wrappings. (5) Cleaning visible soil on hermetically sealed containers of food before opening. (6) Protecting food containers that are received packaged together in a case or overwrap from cuts when the case or overwrap is opened. (7) Separating damaged, spoiled, or recalled food being held on the vessel. (8) Separating unwashed fruits and vegetables from ready-to-eat food.
|
|
|
Item No.:
16
|
|
Site:
Galley-Cold Pantry
|
|
Violation:
A small hotel pan of chicken liver mousse inside undercounter reach-in refrigerator MG2-63 had an internal temperature of 43-45 °F. A tray of slice prosciutto ham was in the same refrigerator at 44 °F, and a tray of ratatouille canape inside had a food temperature of 44-45 °F. All were immediately removed and blast-chilled.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
|
|
|
Item No.:
16
|
|
Site:
Galley-Cold Pantry
|
|
Violation:
A sheet pan of rice stuffed grape leaves (dolmades) was at a temperature of 46-48 °F inside the walk-in refrigerator. It was immediately removed and blast-chilled.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
|
|
|
Item No.:
36
|
|
Site:
Galley-Room Service
|
|
Violation:
The artificial light level behind and around the counter model toaster and bread slicer was below the minimum 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
16
|
|
Site:
Galley-Time Control Plan - Hot Galley
|
|
Violation:
The time only as a public health control plan did not specifically address the various ice bath and room temperature mise en place preparations for batters, sauces, omelets which were on counters throughout the hot galley on time control.
|
|
Recommendation:
Include the various mise en place preparations of potentially hazardous foods on the written time as a public health control plans.
|
|
|
Item No.:
39
|
|
Site:
Galley-Pastry
|
|
Violation:
One live filth fly was observed circulating in this area during active preparation.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
36
|
|
Site:
Galley-Pastry
|
|
Violation:
The artificial light level behind the forward of the two stack ovens was below the minimum 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
19
|
|
Site:
Galley-Bakery
|
|
Violation:
Inside a large trolley of bread crumbs beneath the pastry counter was a small black 1/2 inch strip of what was believed to be an old rind from a lime. Additionally, buried in the breadcrumbs was a spray can of canola oil.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
39
|
|
Site:
Galley-Bakery
|
|
Violation:
One live filth fly was observed on the side exterior of the knife locker.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
39
|
|
Site:
Galley-Room Service
|
|
Violation:
One live filth fly was observed on the bulkhead mounted overshelf near the two ice machines.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
30
|
|
Site:
Galley-Handwash Stations
|
|
Violation:
The paper towel dispensers throughout the galley were a pull-type unit designed to leave a small tag end of paper to pull the next sheet, but nearly half of the units did not function properly and a wheel on the side of the dispenser had to be used to advance the paper. In 3 of 5 the wheel exterior was soiled and not easy to clean.
|
|
Recommendation:
Keep handwashing facilities clean and in good repair.
|
|
|
Item No.:
16
|
|
Site:
Galley-Cooling Logs
|
|
Violation:
The two hour log entries for items like bolognaise sauce, chicken, veal, and fish stock, and tomato sauces were in some cases over the 70 °F temperature (72-76 °F). There was no step or measure recorded in these cases and the foods were continued in cooling mode to temperatures below 41 °F within 4 hours of that check.
|
|
Recommendation:
Ensure cooked potentially hazardous food is cooled from 57°C (135°F) to 21°C (70°F) within 2 hours and from 21°C (70°F) to 5°C (41°F) or less within 4 hours.
Ensure that if the 2 hour control limit is not met that those foods are either re-heated and cooled again or served, but they should not be continued in the cooling process. Recommend evaluating foods at points such as 1.5 hours to verify if the temperatures are too high so measures can be taken before the 2 hour control point is reached.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-Consumer Advisory
|
|
Violation:
Consumer advisories were posted on sneeze shields in La Veranda Buffet, but they were not located at the specific sections where animal-derived foods such as eggs, hamburgers, and steaks were cooked to order. In both the Compass Rose and Prime 7 dining room menu's there were consumer advisories at the footnote of the menu's, but no star at each individual food which was not fully cooked by either passenger request or by recipe.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., ?oysters on the half-shell,? ?hamburgers,? ?steaks,? or ?eggs?); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order OR (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Crew Mess
|
|
Violation:
The deckhead over the buffet line was soiled with food residue. The inspection took place just as lunch food items were being placed out for service.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Crew Mess - Beverage Station
|
|
Violation:
The artificial light level behind and around the counter-mounted water/ice dispenser, microwave oven, and juice dispenser was below the minimum 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
21
|
|
Site:
Buffet-Crew Mess - Beverage Station
|
|
Violation:
The water tubing and power cord to the coffee machine were draped on the counter top, making cleaning behind difficult.
|
|
Recommendation:
Elevate water supply tubes and power cables so cleaning of counters is easy.
|
|
|
Item No.:
26
|
|
Site:
Galley-Crew Galley - Dishwash
|
|
Violation:
A few of the previously cleaned knives in the clean storage rack were found soiled with food residue.
|
|
Recommendation:
Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Officers Mess
|
|
Violation:
The artificial light level behind the beverage machines on the counter was below the minimum 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Officers Mess
|
|
Violation:
There was no coving at the deck juncture with the waiter station counter foundation.
|
|
Recommendation:
Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
|
|
|
Item No.:
17
|
|
Site:
Provisions-Parasite Destruction Certification
|
|
Violation:
The letters verifying the raw and cold-smoked fish served ready-to-eat were free of parasites did not explain the temperature and time these fish were frozen to. The letters all stated that all necessary steps were taken to meet the requirements and that these fish were held at a warehouse prior to transfer to the ship.
|
|
Recommendation:
If raw, raw-marinated, partially cooked, or marinated partially cooked fish are served in ready-to-eat form, ensure: (1) The person in charge records the freezing temperature and time to which the fish are subjected and retains the records on the vessel for 90 calendar days beyond the time of service or sale of the fish; or (2) If the fish are frozen by a supplier, a written letter from the supplier which specifies the fish species involved and both the temperature to which the fish was frozen and the total time period at that temperature. If the supplier provides any of the same species to the vessel in a fresh state, ensure there is a designation on the outer packaging for the parasite-free fish.
These letters need to be specific and state what time and temperature the fish were frozen to.
|
|
|
Item No.:
39
|
|
Site:
Buffet-La Veranda Starboard Line
|
|
Violation:
There were 4 live fruit flies at the deckhead and handwash sink on the forward corner of this buffet.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
39
|
|
Site:
Buffet-La Veranda Port Line
|
|
Violation:
Five live fruit flies were observed on the deckhead in the aft section during lunch service.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
33
|
|
Site:
Buffet-La Veranda Port Line
|
|
Violation:
There was a layer of dust soil on the deckhead vent cover which extended the length of the bulkhead behind the food line..
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
38
|
|
Site:
Galley-La Veranda - Coffee Station
|
|
Violation:
The counter model espresso/cappuccino machine was in disrepair and had been out of order for over 1.5 years according to staff.
|
|
Recommendation:
Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
|
|
|
Item No.:
18
|
|
Site:
Galley-Le Veranda - Hot Galley
|
|
Violation:
There was a full hotel pan of cut strips of raw fish in contact on one side with a pan of cooked mixed vegetables. On the other side of the fish pan was a staff member cutting up pieces of fully cooked chicken for placing on the buffet line. The preparation counter on the cooking line was not in use at the time and there was space at a second small table on the cooking line just beside the fryer. Staff moved the pan of raw fish to the preparation counter at the cooking line.
|
|
Recommendation:
Protect food from cross-contamination or other sources of contamination by the following methods: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food so that products do not physically touch and so that one product does not drip into another. (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry?except when combined as ingredients?during storage, preparation, holding, and display by using separate equipment for each type, or by arranging each type of food in equipment so that cross-contamination of one type with another is prevented, or by preparing each type of food at different times or in separate areas. (3) Cleaning and sanitizing equipment and utensils. (4) Storing the food in packages, covered containers, or wrappings. (5) Cleaning visible soil on hermetically sealed containers of food before opening. (6) Protecting food containers that are received packaged together in a case or overwrap from cuts when the case or overwrap is opened. (7) Separating damaged, spoiled, or recalled food being held on the vessel. (8) Separating unwashed fruits and vegetables from ready-to-eat food.
|
|
|
Item No.:
40
|
|
Site:
Other-Lido Grill
|
|
Violation:
The pantry door to the outside grill is left partly open during the grill service. The door self-closing mechanism appeared not to work and staff did not pull the door closed behind them.
|
|
Recommendation:
Protect entry points where pests may enter the food areas.
|
|
|
Item No.:
19
|
|
Site:
Bar-Pool Bar
|
|
Violation:
The ice cream dipper well at the corner of the front bar counter was not shielded from the passengers who can stand and order directly in front of the counter.
|
|
Recommendation:
Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
|
|
|
Item No.:
40
|
|
Site:
Pantry-Pool Bar - Pantry
|
|
Violation:
The pantry door was fully opened and latched to hold the door open. As this bar is on an open deck this practice allows entry of pests into the pantry. When checked later in the inspection this door remained latched open.
|
|
Recommendation:
Protect entry points where pests may enter the food areas.
|
|
|
Item No.:
21
|
|
Site:
Bar-Navigator Bar
|
|
Violation:
The flexible steel water line at the espresso/cappuccino machine was coiled on the counter below, making access and cleaning difficult.
|
|
Recommendation:
Shorten or elevated the water line to make the counter below the machine easy to clean.
|
|
|
Item No.:
33
|
|
Site:
Bar-Navigator Bar
|
|
Violation:
There was heavy dust accumulated in the gap between the deckhead panels throughout this bar. Additionally there was dust build-up along the length of the supply vent cover which is installed on the deckhead over the front bar counter.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Test Kit
|
|
Violation:
There were no secondary standards for the electronic test kit being used to test for halogen residuals.
|
|
Recommendation:
Ensure the halogen test kit used to calibrate the halogen analyzer is accurate to within 0.2 mg/L (ppm) for halogen and graduated in increments no greater than 0.2 mg/L (ppm) in the range of free residual halogen normally maintained in the potable water system. Ensure all reagents used with the test kit are not past their expiration dates. Where available, maintain appropriate secondary standards onboard for electronic test kits to verify test kit operation.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Shock Chlorination
|
|
Violation:
Free chlorine residual values were not being recorded at the start and end of whirlpool shock chlorination.
|
|
Recommendation:
Increase the free residual halogen to at least 10.0 mg/L (ppm) and circulate for at least 1 hour every 24 hours. Test the free residual halogen both at the start and completion of shock halogenation. Superhalogenate the water in the entire RWF system to 10 ppm to include the whirlpool spa/spa pool tub, compensation tank, filter housing, and all associated piping before starting the 1-hour timing.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Filter Housing
|
|
Violation:
There were no records being kept on the filter housing cleaning and disinfecting for all the RWFs.
|
|
Recommendation:
Clean, rinse, and disinfect the filter housing before the new filter media is placed in it. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Turnover Rates and Bather Loads
|
|
Violation:
The turnover rates for all the RWFs were not available. Additionally, bather loads were not calculated on the RWF's.
|
|
Recommendation:
For RWFs with skim gutters, ensure that the fill level of the RWF is to the level of the skim gutters. Design recirculation systems and equipment, including chemical control equipment, UV disinfection systems, filter, and pumps to maintain adequate water chemistry control while operating at the following minimum turnover rates: (1) swimming pool (VSP 2005 Construction Guidelines or earlier): 6 hours; (2) swimming pool (VSP 2011 Construction Guidelines or later): 4 hours; (3) children's pool: 0.5 hours; (4) wading pool: 1 hour; (5) whirlpool spa: 0.5 hours; (6) spa pool: 2 hours; (7) interactive RWF or activity pool less than 610 millimeters (24 inches) deep: 1 hour; (8) interactive RWF or activity pool greater than 610 millimeters (24 inches) deep: 2 hours; and (9) baby-only water facility: 0.5 hours. Ensure an RWF slide that is combined with a pool has a turnover rate that matches the rate for the pool. Maintain documentation on the maximum bather load for each RWF. Ensure the maximum bather load is based on the following factor: one person per five gallons (19 liters) per minute of recirculation flow.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Automated pH Testing
|
|
Violation:
There were no chart recorders or electronic data loggers with security features that record pH for each individual recreational water facilities.
|
|
Recommendation:
Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration. In the event of equipment failure, measure free residual halogen and pH by a manual test kit at the RWF or return line at least hourly for whirlpool spas, spa pools, children?s pools, and wading pools and every 4 hours for all other RWFs. Record manual readings on a chart or log, retain for at least 12 months, and ensure that they are available for review during inspections. Complete repairs on malfunctioning halogen analyzer-chart recorders within 30 days of equipment failure. Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Halogen and pH Analyzer Probe Locations
|
|
Violation:
The sample line locations for free halogen residual and pH probes for all recreational water facilities were located after the compensation tank.
|
|
Recommendation:
Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration. In the event of equipment failure, measure free residual halogen and pH by a manual test kit at the RWF or return line at least hourly for whirlpool spas, spa pools, children?s pools, and wading pools and every 4 hours for all other RWFs. Record manual readings on a chart or log, retain for at least 12 months, and ensure that they are available for review during inspections. Complete repairs on malfunctioning halogen analyzer-chart recorders within 30 days of equipment failure. Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Safety Signs
|
|
Violation:
The safety signs for all the RWFs did not meet the requirements of the 2011 VSP Operations Manual.
|
|
Recommendation:
Provide safety signs for all RWFs, except for baby-only water facilities. Ensure the signs, at a minimum, include the following words: (1) do not use these facilities if you are experiencing diarrhea, vomiting, or fever; (2) no children in diapers or who are not toilet trained; (3) shower before entering the facility; and (4) bather load #. For children?s RWF signs, include the exact wording ?TAKE CHILDREN ON FREQUENT BATHROOM BREAKS? or ?TAKE CHILDREN ON FREQUENT TOILET BREAKS.? In addition to the safety sign requirements in section 6.7.1.1.1, install a sign at each whirlpool spa and spa pool entrance listing precautions and risks associated with the use of these facilities. Include, at a minimum, cautions against use by the following: (1) individuals who are immunocompromised; (2) individuals on medication or who have underlying medical conditions such as cardiovascular disease, diabetes, or high or low blood pressure; and (3) pregnant women, elderly persons, and children. Additionally, caution against exceeding 15 minutes of exposure.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Test Kit
|
|
Violation:
There was no test kit available that could measure for total halogen and total alkalinity.
|
|
Recommendation:
Ensure a test kit is available for testing water quality parameters, including free and total halogen levels (chlorine and bromine, where applicable), pH, and total alkalinity. Ensure that test kits are accurate to within 0.2 mg/L (ppm) for halogen and have a testing range of free residual halogen normally maintained in the RWF. Ensure test kits for pH are accurate to within 0.2. Ensure all reagents are not past their expiration dates.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Antientrapment Drain Covers
|
|
Violation:
There was no documentation available that showed the drain covers in both the swimming pool and both whirlpools were ASME A112.19.8-2007 compliant. The drains in the pool were gravity, multiple, and greater than 3 feet apart with no alarm. The whirlpools had single gravity drains.
|
|
Recommendation:
For RWFs with gravity drainage and multiple drains (2 or more drains greater than 3 feet apart), provide either a standard design (not compliant with ASME A112.19.8) drain cover and an alarm, or an ASME A112.19.8 compliant antientrapment/antientanglement drain cover. Ensure the alarm is audible and sounds in both a continuously manned space and at the RWF. Ensure this alarm is for all draining: accidental, routine, and emergency. For RWFs with gravity drainage and a single blockable drain or multiple drains less than 3 feet apart, provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a gravity drainage system.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-pH Monitoring
|
|
Violation:
pH values were not being monitored during water production and bunkering.
|
|
Recommendation:
After the free residual halogen level of at least 2.0 mg/L (ppm) and pH level not exceeding 7.8 have been reached, monitor the free residual halogen and pH at least hourly during the bunkering of potable water. After the free residual halogen level of at least 2.0 mg/L (ppm) and pH level not exceeding 7.8 have been reached, monitor the free residual halogen and pH at least once every 4 hours during the production of potable water.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Depth Markers
|
|
Violation:
The depth markers at the swimming pool were not readily visible from both the deck and the pool.
|
|
Recommendation:
Prominently display the depth of each RWF that is deeper than 1 meter (3 feet) so that it can be seen from the deck and in the pool. Label depth markers in both feet and meters. Additionally, install depth markers for every 1 meter (3 feet) change in depth.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Rescue Hook
|
|
Violation:
The pole of the rescue hook at the swimming pool was not long enough to reach the center of the deepest portion of the pool from side plus 2 feet.
|
|
Recommendation:
Provide a rescue or shepherd?s hook and an approved flotation device at a prominent location (visible from the full perimeter of the pool) at each RWF that has a depth of 1 meter (3 feet) or greater. Mount these devices in a manner that allows for easy access during an emergency. Ensure the pole of the rescue or shepherd?s hook is long enough to reach the center of the deepest portion of the pool from the side plus 2 feet. Ensure it is a light, strong, nontelescoping material with rounded, nonsharp ends. Ensure the approved flotation device includes an attached rope that is at least 2/3 of the maximum pool width.
|
|
|
Item No.:
10
|
|
Site:
Housekeeping-Private Whirlpool
|
|
Violation:
Records for the private whirlpool cleaning and disinfection were not being recorded.
|
|
Recommendation:
Maintain a record outlining the frequency of cleaning and disinfection. Ensure the record includes the type, concentration, and contact time of the disinfectant. Retain records on the vessel for 12 months.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Outbreak Prevention and Response Plan (OPRP)
|
|
Violation:
The OPRP did not have a way to notify passengers and crew members of an existing outbreak as well as informing passengers embarking the vessel following an outbreak voyage.
|
|
Recommendation:
Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (1) Duties and responsibilities of each department and their staff for all the passenger and crew public areas; (2) Steps in outbreak management and control and the trigger for required action at each step. Ensure the triggers address a graduated approach to outbreak management in response to increasing case counts; (3) Disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times. Ensure the disinfectant products or systems are effective against human norovirus or an acceptable surrogate (e.g., caliciviruses); (4) Procedures for informing passengers and crew members of the outbreak. Ensure this section also includes procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage; (5) Procedures for returning the vessel to normal operating conditions after an outbreak; (6) Procedures to protect the passengers and crew from exposure to disinfectants, if not already included in the vessel?s safety management system. Ensure this protection includes: (a) Material safety data sheets (MSDSs); (b) Personal protective equipment for crew; (c) Health and safety procedures to minimize respiratory and dermal exposures to both passengers and crew.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Active Surveillance
|
|
Violation:
The time of active monitoring inspections was not being recorded in the log.
|
|
Recommendation:
Ensure the IPM Plan includes provisions for logs for active monitoring of pest sightings in operational areas of the vessel. Ensure the IPM plan includes provisions for training of crew members in charge of log completion. Record the time of the active monitoring inspections in the log.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Log
|
|
Violation:
Follow-up records were not being recorded in the log when pests were observed.
|
|
Recommendation:
When pests are noted during an inspection, ensure the log includes action taken and follow-up inspection results.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Tank Maintenace
|
|
Violation:
There was no written documentation of approval from a certification organization (independent of the coating manufacturer) that the tank coating being used is approved for potable water contact.
|
|
Recommendation:
Ensure the interior coatings on potable water tanks are approved for potable water contact by a certification organization. Follow all manufacturers? recommendations for application, drying, and curing. For the tank coatings used, maintain the following onboard: (1) written documentation of approval from the certification organization (independent of the coating manufacturer); (2) manufacturers? recommendations for application, drying, and curing; and (3) written documentation that the manufacturers? recommendations have been followed for application, drying, and curing.
|
|