Item No.:
29
|
|
Site:
Buffet-Port Side Hot Line
|
|
Violation:
The water temperature at the handwashing sink was less than 100°F.
|
|
Recommendation:
Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet.
|
|
|
Item No.:
16
|
|
Site:
Buffet-Time Control Plan
|
|
Violation:
The undercounter hot holding units on time control were not labeled as time control. They were listed on the plan and all items on time control had discard labels.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such).
|
|
|
Item No.:
16
|
|
Site:
Galley-Time Control Plan
|
|
Violation:
The upright reach-in refrigeration units were labeled as time control, but were not listed on the plan.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such).
|
|
|
Item No.:
16
|
|
Site:
Food Service General-Consumer Advisories
|
|
Violation:
There were no consumer advisories at the buffets for eggs made to order or served undercooked or the cold smoked salmon. The restaurant menus did not have consumer advisories for the animal-derived foods that could be served raw or undercooked.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., ?oysters on the half-shell,? ?hamburgers,? ?steaks,? or ?eggs?); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order OR (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
|
|
|
Item No.:
29
|
|
Site:
Galley-Garde Manger
|
|
Violation:
At the handwashing station by the entrance to the garde manger, the water temperature was measured at 125°F and the user could not adjust the temperature. There was another handwashing station within 8 meters.
|
|
Recommendation:
For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
|
|
|
Item No.:
20
|
|
Site:
Food Service General-Tip-sensitive Thermometers
|
|
Violation:
The cooks who prepared thin foods did not have tip-sensitive thermometers.
|
|
Recommendation:
Ensure food temperature-measuring devices are provided and readily accessible for use in ensuring attainment and maintenance of food temperatures. Use tip-sensitive temperature-measuring devices, such as a thermocouple or thermistor, for measuring thin food products.
|
|
|
Item No.:
36
|
|
Site:
Food Service General-Light Intensity
|
|
Violation:
The light intensity behind and around many pieces of deck-mounted and counter-mounted equipment was less than 110 lux. This included combination ovens, stack ovens, ice machines and beverage machines in galleys, pantries, bars, and buffets.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
16
|
|
Site:
Buffet-Time Control Plan
|
|
Violation:
The plan did not list the counter top-mounted pass-through refrigerator as being on time control. The unit was labeled.
|
|
Recommendation:
Ensure plan(s): (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such).
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-
|
|
Violation:
Follow-up inspections after the treatment of pests were not recorded if there were no pests identified during the follow-up inspection.
|
|
Recommendation:
When pests are noted during an inspection, ensure the log includes action taken and follow-up inspection results.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-
|
|
Violation:
Active monitoring inspections were only recorded if pests were identified. From the records, it was unclear which areas were inspected or what time the inspections occurred.
|
|
Recommendation:
Ensure the IPM Plan includes provisions for logs for active monitoring of pest sightings in operational areas of the vessel. Ensure the IPM plan includes provisions for training of crew members in charge of log completion. Record the time of the active monitoring inspections in the log.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-
|
|
Violation:
There were no records for pest inspections of incoming stores. Staff stated that loading inspections were only recorded if there was a pest found.
|
|
Recommendation:
Routinely inspect incoming shipments of food and all other supplies for evidence of insects, rodents, and other pests. Maintain a record of these inspections onboard the vessel and make the record available for review during inspections.
|
|
|
Item No.:
03
|
|
Site:
Potable Water-Production
|
|
Violation:
Records indicated that potable water was produced while making way in the Amazon River throughout 25 December - 4 January. Voyage 122 embarked on 16 December from Port Everglades, FL and disembarked on 30 December in Manaus, Brazil. Voyage 201 embarked on 30 December from Manaus, Brazil and disembarked on 13 January in Port Everglades, Florida.
|
|
Recommendation:
Operate a reverse osmosis unit, distillation plant, or other process that supplies water to the vessel?s potable water system only while the vessel is making way, and do not operate in polluted areas, harbors, or at anchor.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Whirlpool Pump Room
|
|
Violation:
The air gaps for the make-up hot and cold potable water to the whirlpool compensation tank was not at least twice the diameter of the supply lines. This was corrected.
|
|
Recommendation:
Ensure air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 25 millimeters (1 inch).
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Thalasso Spa Pool Pump Room
|
|
Violation:
The air gap for the potable water make up line to the Thalasso compensation tank was not at least twice the diameter of the supply line.
|
|
Recommendation:
Ensure air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 25 millimeters (1 inch).
|
|
|
Item No.:
10
|
|
Site:
Housekeeping-Private Cabin Whirlpool Cleaning
|
|
Violation:
The records for disinfecting the private cabin whirlpools did not indicate a contact time.
|
|
Recommendation:
Maintain a record outlining the frequency of cleaning and disinfection. Ensure the record includes the type, concentration, and contact time of the disinfectant. Retain records on the vessel for 12 months.
|
|
|
Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Surveillance Log
|
|
Violation:
The electronic medical AGE surveillance log did not include all fields and was not ordered exactly as the log in 13.2.2 of the VSP Operations Manual.
|
|
Recommendation:
Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Date of the first medical visit or report to staff of illness; (2) time of the first medical visit or report to staff of illness; (3) case identification number; (4) person?s name; (5) person?s age; (6) person?s sex; (7) designation as passenger or crew member; (8) crew member position or job on the vessel, if applicable; (9) cabin number; (10) meal seating information; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24-hour period; (b) number of episodes of vomiting in a 24-hour period; (c) bloody stools; (d) recorded temperature; (e) abdominal cramps; (f) headaches; (g) muscle aches; (14) entry (yes/no) for whether this was a reportable case; (15) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (16) presence of underlying medical conditions that may affect interpretation of AGE. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Chemical Locker 713
|
|
Violation:
Potable water lines to the chemical sink were not striped or painted either in accordance with ISO 14726 (blue/green/blue) or blue only. This was corrected.
|
|
Recommendation:
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only.
|
|