|
|
|
Item No.:
08
|
|
Site:
Potable Water-Striping
|
|
Violation:
The distillate lines from the 2 evaporators were not striped blue/gray/blue to the chlorine injection system.
|
|
Recommendation:
Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-pH Monitoring
|
|
Violation:
There was no documentation that the pH was monitored every hour during bunkering or every four hours during production since December 5, 2012.
|
|
Recommendation:
After the free residual halogen level of at least 2.0 mg/L (ppm) and pH level not exceeding 7.8 have been reached, monitor the free residual halogen and pH at least hourly during the bunkering of potable water. After the free residual halogen level of at least 2.0 mg/L (ppm) and pH level not exceeding 7.8 have been reached, monitor the free residual halogen and pH at least once every 4 hours during the production of potable water. Maintain accurate records of production and bunkering monitoring aboard for 12 months and ensure these records are available for review during inspections.
|
|
|
Item No.:
03
|
|
Site:
Potable Water-Bunkering
|
|
Violation:
On December 17, 2011, the free chlorine residual during bunkering was between 0.5 - 0.7 ppm. Bunkering was done between 9:00 a.m. and 3:00 p.m. The documentation stated there was no flow meter available and the pH was high on the shore side water supply. On December 22, 2011, documentation stated that the free chlorine residual was 0.1 ppm each hour bunkering occurred from 10:00 a.m. - 7:00 p.m. The documentation stated the pH of 9.1 was too high from the shore side water supply. According to the staff, the free chlorine residual sensor was not working properly. On December 28, 2011, documentation stated the free chlorine residual was between 0.1 - 0.4 ppm during bunkering between 8:00 a.m. - 4:00 p.m. and the pH of 9.3 was too high from the shore side water supply.
|
|
Recommendation:
Continuously halogenate potable water to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device that is controlled by a flow meter and adjust the pH so it does not exceed 7.8. Ensure the amount of halogen injected during bunkering or production is controlled by a flow meter or a free halogen analyzer.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross-Connection Control Log
|
|
Violation:
On the cross-connection control log, the backflow prevention device to protect the bunkered potable water from the technical water line was described by the serial number and the location of the device was listed as being in the sanitary pump room port instead of the port evaporator room. Also, the backflow prevention device for the potable water connection used to wash the technical tank in the starboard stabilizer room, and the starboard and port mineralizer and backwash connections were described as serial numbers and the devices could not be matched to the plumbing components. In addition, the backflow prevention devices on the hot and cold water lines to the handwash sink in the deck 4 incinerator room were not on the cross-connection control list and were painted over, making them very difficult to access for maintenance. The backflow prevention device for the spray hose to wash down the equipment in the deck 3 incinerator room was listed on the cross-connection control list as 'near staircase' and the device could not be matched to the plumbing component. Also, one backflow prevention device for the pedicure throne was listed as an S8 on the cross-connection control list but upon inspection there were two dual check devices with no vents on both the hot and cold water lines to the pedicure throne.
|
|
Recommendation:
Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Ensure backflow prevention devices and air gaps are accessible for inspection, service, and maintenance. Ensure the backflow prevention devices on the pedicure throne are vented.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Incinerator Room Striping
|
|
Violation:
On deck 4, the hot and cold potable water lines to the spray hose used to wash drums and to the handwashing sink were not striped or painted blue. Also, it was unclear if the potable water lines to the pulper on deck 4 were striped or painted blue every 15 feet. The paint was peeling and it was difficult to see all of the lines. In addition, the cold potable water line to the hose bib next to the air connection on deck 4 was not striped or painted blue. On deck 3, the potable water line to the hose for washing equipment was not striped or painted blue every 15 feet.
|
|
Recommendation:
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers.
|
|
|
Item No.:
43
|
|
Site:
Ventilation-
|
|
Violation:
There was no sight glass or way to easily access the condensate collection pans in A/C unit 210.
|
|
Recommendation:
Ensure air handling unit condensate drain pans and collection systems are able to be accessed for inspection, maintenance, and cleaning. Install sight windows or use other effective methods to allow for full inspection of condensate collection pans when original equipment access makes evaluation during operational inspections impractical.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Fecal and Vomit Accident Log
|
|
Violation:
The fecal and vomit accident log did not include vomit as a type. Also, the disinfection contact times for loose stool accidents were not correct. In addition, there was no way to indicate in which RWF the accident occurred.
|
|
Recommendation:
Ensure a written or electronic record is made of all accidents involving fecal material or vomit. Ensure the record includes the name of the RWF, date and time of the accident, type of accident, response steps taken, and free residual halogen level and contact time reached during disinfection. For a fecal accident, ensure the record also includes whether the fecal material was formed or loose.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Active Surveillance Log
|
|
Violation:
There was no information on the follow-up inspection results or action taken when pests were noted on the active surveillance log.
|
|
Recommendation:
When pests are noted during an inspection, ensure the log includes action taken and follow-up inspection results.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Filter Housing Disinfection
|
|
Violation:
The cartridge filters for the RWFs were cleaned and rinsed, but not disinfected before new media was placed in the filter housing.
|
|
Recommendation:
Clean, rinse, and disinfect the filter housing before the new filter media is placed in it. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Bather Load
|
|
Violation:
There was no documentation for the bather load calculations for any of the RWFs.
|
|
Recommendation:
Maintain documentation on the maximum bather load for each RWF. Ensure the maximum bather load is based on the following factor: one person per five gallons (19 liters) per minute of recirculation flow.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Safety Signs
|
|
Violation:
The safety signs for the swimming pool and whirlpools did not meet the requirements of the 2011 VSP Operations Manual.
|
|
Recommendation:
Provide safety signs for all RWFs, except for baby-only water facilities. Ensure the signs, at a minimum, include the following words: (1) do not use these facilities if you are experiencing diarrhea, vomiting, or fever; (2) no children in diapers or who are not toilet trained; (3) shower before entering the facility; and (4) bather load #. In addition to the safety sign requirements in section 6.7.1.1.1, install a sign at each whirlpool spa and spa pool entrance listing precautions and risks associated with the use of these facilities. Include, at a minimum, cautions against use by the following: (1) individuals who are immunocompromised; (2) individuals on medication or who have underlying medical conditions such as cardiovascular disease, diabetes, or high or low blood pressure; and (3) pregnant women, elderly persons, and children. Additionally, caution against exceeding 15 minutes of exposure.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Antientrapment
|
|
Violation:
The swimming pool had dual gravity drains greater than 3 feet apart, and it could not be determined if the drain covers met the antientrapment standards. There was an alarm for draining but the alarm could not be heard at the RWF.
|
|
Recommendation:
For RWFs with gravity drainage and multiple drains (2 or more drains greater than 3 feet apart), provide either a standard design (not compliant with ASME A112.19.8) drain cover and an alarm, or an ASME A112.19.8 compliant antientrapment/antientanglement drain cover. Ensure the alarm is audible and sounds in both a continuously manned space and at the RWF. Ensure this alarm is for all draining: accidental, routine, and emergency.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Hair and Lint Strainer
|
|
Violation:
The hair and lint strainers and the hair and lint strainer housings for the whirlpools were not cleaned, rinsed, or disinfected on any regular basis.
|
|
Recommendation:
Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Shock Halogenation
|
|
Violation:
The free chlorine residual levels at the start and completion of shock halogenation for the whirlpools were not recorded. The documentation stated that the free chlorine residual was greater than 10 ppm for 1 hour.
|
|
Recommendation:
Ensure a written or electronic record of the date and time of water dumping and shock halogenation (concentration in ppm at the start and completion and time) is available for review during inspections.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Shock Halogenation
|
|
Violation:
There was no documentation or indication that shock halogenation was done for the mid, port, and starboard whirlpools on December 14-19, 27 or 31, 2011, or on January 1, 2012.
|
|
Recommendation:
Increase the free residual halogen to at least 10.0 mg/L (ppm) and circulate for at least 1 hour every 24 hours. Test the free residual halogen both at the start and completion of shock halogenation. Superhalogenate the water in the entire RWF system to 10 ppm to include the whirlpool spa/spa pool tub, compensation tank, filter housing, and all associated piping before starting the 1-hour timing. Ensure a written or electronic record of the date and time of water dumping and shock halogenation (concentration in ppm at the start and completion and time) is available for review during inspections.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Dumping
|
|
Violation:
Documentation only stated that dumping occurred on the mid whirlpool on December 19, 2011, all whirlpools on March 17, 2012, and the mid whirlpool on December 14 and 15, 2011. According to the staff, dumping of whirlpool water occurred every 3 - 5 days or whenever they felt it was needed. The last documented dumping before March 17, 2012 was February 24, 2012.
|
|
Recommendation:
Change the whirlpool spa water, including compensation tank, filter housing, and associated piping, every 72 hours, provided that the system is operated continuously and that the correct water chemistry levels are maintained during that period, including daily shock halogenation. Change the water at least every 30 days. Record the date and time of whirlpool spa and spa pool water changes in the log. Ensure a written or electronic record of the date and time of water dumping and shock halogenation (concentration in ppm at the start and completion and time) is available for review during inspections.
|
|
|
Item No.:
11
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Log
|
|
Violation:
For a galley utility worker, the AGE log indicated symptoms on March 10, 2012 at noon, but this person did not report to medical until March 14, 2012 at midnight. This individual worked on March 15, 2012 from 8:18 p.m. until 1:50 a.m.
|
|
Recommendation:
When food employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document date and time of last symptom and clearance to return to work. Exclude food employees suspected of, diagnosed with, or exposed to any communicable disease caused by Salmonella typhi, Shigella spp., E. coli O157:H7, hepatitis A virus, norovirus, or other communicable diseases that can be transmitted by food, from working in any food or food related areas or operations, including working with exposed food, warewashing, equipment, utensils, table linens, single-service articles and single-use articles. Do not allow the excluded individual to return to the above duties until they are symptom free for a minimum of 48 hours.
|
|
|
Item No.:
44
|
|
Site:
Other-Potable Water and Recreational Water Facilities
|
|
Violation:
The person in charge of the cross-connection control log and the RWFs had a difficult time answering important public health questions about how the RWF systems worked, where all of the equipment was, and how the equipment was disinfected. Also, this person had difficulty identifying the type and location of the backflow prevention devices around the ship.
|
|
Recommendation:
Ensure the supervisor or person in charge of potable water operations on the vessel demonstrates to VSP?during inspections and on request-knowledge of potable water operations, is able to demonstrate this knowledge by compliance with Section 5 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 5 of the VSP 2011 Operations Manual as it relates to their assigned duties.
Ensure the supervisor or person in charge of recreational water operations on the vessel demonstrates to VSP?during inspections and on request ? knowledge of recreational water operations, is able to demonstrate this knowledge by compliance with Section 6 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 6 of the VSP 2011 Operations Manual as it relates to their assigned duties.
|
|
|
Item No.:
16
|
|
Site:
Buffet-La Veranda and Pool Grill
|
|
Violation:
There were no posted consumer advisories for the eggs cooked to order at the omelet station, the cold smoked salmon on the cold buffet, or the eggs benedict that could be ordered at the table. Staff provided placards with the consumer advisory statement, but the specific raw or undercooked animal-derived food items were not included. In addition, the placard with the consumer advisory statement for the pool grill did not include that hamburgers or cheeseburgers could be cooked to order.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that disclosure is made on a sign describing the animal-derived foods (e.g., ?oysters on the half-shell,? ?hamburgers,? ?steaks,? or ?eggs?); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-Dining Room Consumer Advisories
|
|
Violation:
There were no consumer advisories on the menus for the two specialty restaurants or the main dining room. Staff provided a draft copy of a menu with the consumer advisory for review.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that disclosure is made by one of the two following methods: (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
|
|
|
Item No.:
29
|
|
Site:
Galley-La Veranda
|
|
Violation:
The water temperature at the handwashing station was 123°F and the user could not adjust the temperature. The water temperature was corrected.
|
|
Recommendation:
Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
|
|
|
Item No.:
36
|
|
Site:
Food Service General-Light Intensity
|
|
Violation:
The light intensity around and behind many deck- and counter-mounted pieces of equipment in the galleys and food service areas was less than 110 lux. The light intensity at the handwashing stations in the Observation Lounge bar and Coffee Corner bar was less than 110 lux during operations. According to the staff, a proposal to correct all of the lighting issues has been submitted to the corporate office.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment. Ensure the light intensity is at least 110 lux (10 foot candles) at handwashing stations in bars.
|
|
|
Item No.:
39
|
|
Site:
Galley-Prime 7
|
|
Violation:
There were three small flies in and around the cleaning locker. The pest management personnel was contacted. This area was closed at the time of the inspection.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
36
|
|
Site:
Food Service General-Light Intensity
|
|
Violation:
The light intensity at the work surfaces in the La Veranda starboard buffet line was less than 220 lux. In addition, the light intensity at the work surfaces in the Coffee Corner bar and the waiter stations in the Compass Rose dining room could not be raised to 220 lux for cleaning. This was written on the previous inspection. According to the staff, a proposal to correct all of the lighting issues has been submitted to the corporate office.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas. In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
|
|
|
Item No.:
17
|
|
Site:
Galley-Cooling Logs
|
|
Violation:
Since March 10, 2012, there were several entries on the hot galley cooling logs that had the initial temperatures recorded between 131 and 134°F. In addition, on March 14, 2012, there were five different sauces on the sauce cooling log that had initial temperatures recorded between 123 and 126°F. According to the logs, the majority of these items were below 41°F after one hour, and all were below 41°F after two hours.
|
|
Recommendation:
Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days form the date the food was placed in the cooling process.
|
|
|
Item No.:
16
|
|
Site:
Galley-Pastry
|
|
Violation:
Upright refrigerator #95 was listed as time control on the time control plan, but the unit was not labeled. The refrigerator was labeled.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such).
|
|
|
Item No.:
37
|
|
Site:
Galley-Port Dishwash Area
|
|
Violation:
There was condensation collected on the inside of the exhaust hood and on the deckhead exhaust vent above the clean end of the in-use conveyor dishwash machine.
|
|
Recommendation:
Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
|
|
|
Item No.:
20
|
|
Site:
Buffet-Officers Mess
|
|
Violation:
The microwave and toaster oven were labeled for household use and were not certified to meet NSF or equivalent standards. The microwave and toaster oven were removed.
|
|
Recommendation:
Ensure food-contact surfaces of food equipment complies with American National Standards Institute (ANSI), National Sanitation Foundation International (NSF International), or other internationally accredited food equipment sanitation standards for materials, design, and construction.
|
|
|
Item No.:
33
|
|
Site:
Preparation Room-Potwash
|
|
Violation:
There was a gap in the bulkhead to the left of the pulper.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
16
|
|
Site:
Preparation Room-Poultry Cold Room
|
|
Violation:
Turkey parts in a plastic bin were measured at 46°F with the inspector's and the chef's thermometers. The turkey had been put in the cold room approximately two hours before. The turkey was put in the blast chiller.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 5°C (41°F) or less.
|
|
|
Item No.:
22
|
|
Site:
Pantry-Observation Lounge and Pool
|
|
Violation:
The data plates for the undercounter warewash machines did not include the wash and final sanitizing rinse times.
|
|
Recommendation:
Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine?s design and operating specifications including the: (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines.
|
|
|
Item No.:
22
|
|
Site:
Bar-Coffee Counter
|
|
Violation:
The data plate for the undercounter warewash machine did not include the wash and final sanitizing rinse times.
|
|
Recommendation:
Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine?s design and operating specifications including the: (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines.
|
|
|
Item No.:
19
|
|
Site:
Bar-Coffee Counter
|
|
Violation:
At the self-service cold counter, a loaf of unsliced bread was not under a sneeze shield. In addition, the unsliced loaf was on a cutting board with a knife and a pair of tongs, and half of the loaf was wrapped in a linen napkin. To serve the bread, consumers would have to handle the bread and slice it themselves. The bread was removed.
|
|
Recommendation:
Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches). Ensure bread out for self service does not need to be handled and sliced by the consumer.
|
|
|
Item No.:
39
|
|
Site:
Bar-Coffee Counter
|
|
Violation:
There were four small flies at the self service cold counter. This area was open and food was out for self service at the time of the inspection.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
22
|
|
Site:
Bar-Coffee Counter
|
|
Violation:
Two sponges were in the sanitizing bucket. The sponges were removed.
|
|
Recommendation:
Do not use sponges in contact with cleaned and sanitized or in-use food-contact surfaces.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Public Toilet Rooms
|
|
Violation:
There were no signs at the handwashing stations advising users to wash their hands. There were also no signs advising users to use a tissue to open the door.
|
|
Recommendation:
Provide the passenger and crew public toilets with a handwashing station that includes: (4) A sign advising users to wash hands. Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Outbreak Prevention and Response Plan (OPRP)
|
|
Violation:
The OPRP included a statement that VSP 2011 required passengers and crew to be informed of an outbreak, including embarking passengers. Staff provided a PA announcement that would be delivered by the captain. However, the procedures were not included in the OPRP.
|
|
Recommendation:
Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (4) Procedures for informing passengers and crew members of the outbreak. Ensure this section also includes procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage.
|
|
|
Item No.:
16
|
|
Site:
Galley-Pastry
|
|
Violation:
Several trays of pastries for the La Veranda buffet were on time control in upright refrigerator #95. However, the trays still had the 7-day discard labels. The labels were removed.
|
|
Recommendation:
Remove all 7-day discard labels when food is placed on time control.
|
|