Cruise Ship: Silver Spirit Cruise Line: Silversea Inspection Date: 03/23/2012 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 36
Site: Food Service General-Light Intensity
Violation: The light intensity was less than 110 lux behind and around many pieces of deck- and counter-mounted equipment in the galleys, pantries and food service areas. Several light fixtures had been installed since the previous inspection and the vessel had a plan for installing additional fixtures.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 19
Site: Buffet-La Terrazza
Violation: Two wide-mouthed bottles of jelly and four bowls of cinnamon, brown sugar, ketchup, and mayonnaise were not under a sneeze shield or otherwise protected. This was corrected.
Recommendation: Protect condiments from contamination by keeping condiments in: (1) Dispensers designed to provide protection; (2) Protected food displays provided with the proper utensils; (3) Original containers designed for dispensing; OR (4) Individual packages or portions.
Item No.: 19
Site: Buffet-La Terrazza
Violation: The food-contact portions of the serving tongs for the breads were not under a sneeze shield or otherwise protected.
Recommendation: During service, ensure the food-contact portion of each self-service food dispensing utensil is covered or located beneath shielding.
Item No.: 19
Site: Buffet-La Terrazza
Violation: A pan of croissants had a hinged lid that could remain open, leaving the croissants unprotected. In addition, the food-contact portion of the serving tongs was not under a sneeze shield or otherwise protected.
Recommendation: Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. During service, ensure the food contact portion of each self-service food dispensing utensil is covered or located beneath shielding.
Item No.: 08
Site: Food Service General-Refrigerant Brine Lines
Violation: The refrigerant brine lines were not uniquely identified.
Recommendation: Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
Item No.: 21
Site: Buffet-Pool Grill
Violation: There were seams where the bottom of the counter-mounted hot rock oven met the counter.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Buffet-Pool Grill
Violation: The bottom of the counter-mounted hot rock oven was soiled in the seams where it met the counter.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Buffet-Pool Grill
Violation: There was a gap where the back, left leg support met the lower counter below the hot rock oven. In addition, the top of the back, middle leg support for this shelf was not fully enclosed, exposing difficult-to-clean features.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 16
Site: Dining Room-Menu Consumer Advisory
Violation: The breakfast menu did not include asterisks at the eggs, which could be cooked to order, or at the cold smoked salmon. In addition, the dinner menu did not include an asterisk at the Chef's Cut, which was beef tenderloin that could be cooked to order.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that disclosure is made on a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 20
Site: Galley-Room Service Pantry Coffee Station
Violation: The panel above the coffee dispensing area on the Italgi coffee machine next to the toaster was corroding. According to the staff, this machine was not being used for making coffee and was scheduled to be removed.
Recommendation: Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition.
Item No.: 30
Site: Galley-Unisex Toilet Room
Violation: There was no toilet tissue.
Recommendation: Provide a supply of toilet tissue at each toilet at all times.
Item No.: 33
Site: Galley-Pastry
Violation: There was some missing and recessed deck grout.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 20
Site: Food Service General-Tip-sensitive Temperature-measuring Devices (TMDs)
Violation: There were no tip-sensitive TMDs for cooks who measure thin foods. According to the staff, TMDs had been ordered and would arrive in April.
Recommendation: Ensure food temperature-measuring devices are provided and readily accessible for use in ensuring attainment and maintenance of food temperatures. Use tip-sensitive temperature-measuring devices, such as a thermocouple or thermistor, for measuring thin food products.
Item No.: 16
Site: Buffet-Officer's Mess
Violation: Except for the title, the time control plan for cold foods was exactly the same as the time control plan for hot foods. This was corrected.
Recommendation: Provide a time control plan for cold foods.
Item No.: 34
Site: Preparation Room-
Violation: There was a leak from the utility sink faucet.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 20
Site: Food Service General-Illy Espresso Machines
Violation: There were slotted fasteners in the food-splash zones above the coffee dispensing area. This was written on the previous inspection. According to the staff, these units were under warranty. The manufacturer had been contacted and was working on a solution.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan (OPRP)
Violation: The outbreak prevention and response plan (OPRP) did not include the procedures for informing the passengers and crew of an outbreak, including embarking passengers. The OPRP included a statement that they would be informed, but did not include any information about the procedures.
Recommendation: Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (4) Procedures for informing passengers and crew members of the outbreak. Ensure this section also includes procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage.
Item No.: 41
Site: Housekeeping-Public Toilet Rooms
Violation: There were no signs at the handwashing stations advising users to wash their hands. In addition, there were no signs advising users to use a hand towel, paper towel, or tissue to open the door. The exits were not hands-free.
Recommendation: Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free. Provide the passenger and crew public toilets with a handwashing station that includes: (4) A sign advising users to wash hands.
Item No.: 24
Site: Galley-Starboard Dishwash Area
Violation: There was no spray from any of the final sanitizing rinse nozzles on the in-use conveyor dishwash machine. According to the staff, the final sanitizing rinse spray had been checked at 0830, but the machine was not put into service until approximately 1030, just before the inspector arrived. A tray of dishes was observed exiting the machine and not being sanitized.
Recommendation: In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
Item No.: 16
Site: Pantry-Bridge
Violation: A container of milk in the undercounter refrigerator and two containers of milk in the espresso machine refrigerator were not labeled with the discard dates. They were only labeled with the dates the containers were opened.
Recommendation: Ensure refrigerated, ready-to-eat, potentially hazardous food: (2) Prepared and packaged by a food-processing plant and held on the vessel after opening for more than 24 hours must be clearly marked at the time the original container is opened to indicate the date by which the food must be consumed (7 calendar days or fewer after the original container is opened). The day of opening is counted as day 1.
Item No.: 02
Site: Medical-Acute Gastroenteritis (AGE) Surveillance Log
Violation: The AGE surveillance log could not be exported into a spreadsheet with the required information in the exact order as specified in Annex 13 of the 2011 VSP Operations Manual. In addition, the passenger meal seating and the crew position information were recorded in the same column and not in separate columns.
Recommendation: Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Date of the first medical visit or report to staff of illness; (2) time of the first medical visit or report to staff of illness; (3) case identification number; (4) person?s name; (5) person?s age; (6) person?s sex; (7) designation as passenger or crew member; (8) crew member position or job on the vessel, if applicable; (9) cabin number; (10) meal seating information; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24-hour period; (b) number of episodes of vomiting in a 24-hour period; (c) bloody stools; (d) recorded temperature; (e) abdominal cramps; (f) headaches; (g) muscle aches; (14) entry (yes/no) for whether this was a reportable case; (15) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (16) presence of underlying medical conditions that may affect interpretation of AGE. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP.
Item No.: 11
Site: Medical-Crew Acute Gastroenteritis (AGE) Reporting
Violation: A galley utility food worker had an onset of AGE symptoms on 25 December 2011 at 1330, but did not report to the medical center until 2000 that day. He did not work but reported going to the crew mess for lunch and dinner before reporting.
Recommendation: When food employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document date and time of last symptom and clearance to return to work. When nonfood employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 24 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document the date and time of last symptom and clearance to return to work.
Item No.: 11
Site: Medical-Crew Acute Gastroenteritis (AGE) Isolation
Violation: On 25 December 2011, a galley utility (food worker) reported to the medical center after experiencing AGE symptoms. His last AGE symptom was recorded as 1500 on that day. Isolation began at that time, but he was released from isolation on 26 December 2011 at 1800. The isolation period lasted 15 hours instead of 48 hours. In addition, on 13 March 2012, a suite attendant (nonfood worker) was released from isolation at 0845, but there was no record of when her last AGE symptom was. With this information it was unclear if she was isolated for 24 hours after her last symptom.
Recommendation: When food employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document date and time of last symptom and clearance to return to work. When nonfood employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 24 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document the date and time of last symptom and clearance to return to work.
Item No.: 08
Site: Potable Water-Tank Maintenance
Violation: Potable water tank FW 12 Starboard was inspected on 5 January 2012 and tank FW 12 Center was inspected on 16 December 2011. A notation stating that the free halogen residual was below 5.00 ppm before the tanks were put back in service was recorded. However, the actual value of the free halogen test result was not documented.
Recommendation: Flush the disinfected parts of the system with potable water or otherwise dechlorinate until the free residual halogen is less than or equal to 5.00 mg/L (ppm). Document the free halogen test result.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: The reduced pressure assemblies installed after evaporators #1 and #2 each had a tube attached to the pressure relief vent. The ends of the tubes could not be located, so it was unclear if there were air gaps.
Recommendation: Provide air gaps either at the vents or at the ends of the tubes.
Item No.: 10
Site: Recreational Water Facilities-Swimming Pool Antientrapment
Violation: The swimming pool had dual gravity drains, but it could not be determined if the covers were antientrapment and there was no alarm installed for draining. According to the staff, new antientrapment drain covers had been ordered.
Recommendation: For RWFs with gravity drainage and multiple drains (2 or more drains greater than 3 feet apart), provide either a standard design (not compliant with ASME A112.19.8) drain cover and an alarm, or an ASME A112.19.8 compliant antientrapment/antientanglement drain cover.
Item No.: 10
Site: Recreational Water Facilities-Safety Signs
Violation: The swimming pool and whirlpool safety signs did not contain all the information specified in the 2011 VSP Operations Manual.
Recommendation: Provide safety signs for all RWFs, except for baby-only water facilities. Ensure the signs, at a minimum, include the following words: (1) do not use these facilities if you are experiencing diarrhea, vomiting, or fever; (2) no children in diapers or who are not toilet trained; (3) shower before entering the facility; and (4) bather load #. For children?s RWF signs, include the exact wording ?TAKE CHILDREN ON FREQUENT BATHROOM BREAKS? or ?TAKE CHILDREN ON FREQUENT TOILET BREAKS.?
Item No.: 10
Site: Recreational Water Facilities-Analyzer Chart Recorders
Violation: The sample lines for the analyzer chart recorders for whirlpool spas #2 and #3 were located after the compensation tanks.
Recommendation: Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank.
Item No.: 10
Site: Recreational Water Facilities-Granular Filter Backwashing
Violation: According to the staff, the backwashing system for the granularfilters was automatic and an individual was not always present ensure backwashing was repeated as necessary until the water was clear. In addition, the length of backwashing was not documented.
Recommendation: Backwash granular filter media until the water viewed through a sight glass runs clear and at the following frequencies: (1) whirlpool spa and spa pool: every 72 hours, or sooner if the whirlpool spa is drained; (2) baby-only water facility: daily; and (3) all other RWFs: at a frequency recommended by the manufacturer. For automatic backwashing systems, ensure an individual is present in the filter room to ensure that backwashing is repeated as necessary until the water runs clear. Clean cartridge filters according to the manufacturer?s recommendations. Maintain a written or electronic record documenting filter backwashing and cleaning. Ensure a written or electronic log of RWF filter inspection results, granular filter sedimentation test results, backwashing frequency and length of backwashing, and date and time of water dumping is available for review during inspections.
Item No.: 10
Site: Recreational Water Facilities-Sedimentation Test Results
Violation: There were no records for the granular filter sedimentation test results.
Recommendation: Record the results of both the filter inspection and sedimentation test.
Item No.: 10
Site: Recreational Water Facilities-Water Chemistry
Violation: There was no means to test for total chlorine and total chlorine was not being monitored.
Recommendation: Monitor and adjust the RWF?s flow rates, free and combined halogen levels, pH, total alkalinity, and clarity as recommended by the manufacturer and to maintain optimum public health protection and water chemistry. Ensure a test kit is available for testing water quality parameters, including free and total halogen levels (chlorine and bromine, where applicable), pH, and total alkalinity. Ensure that test kits are accurate to within 0.2 mg/L (ppm) for halogen and have a testing range of free residual halogen normally maintained in the RWF. Ensure test kits for pH are accurate to within 0.2. Ensure all reagents are not past their expiration dates.
*Inspections scores of 85 or lower are NOT satisfactory