Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Caribbean Princess Cruise Line: Princess Cruises Inspection Date: 04/12/2005 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 21
Site: Bar-PALM 1 WINE BAR
Violation: THE HINGES ON ONE OF THE DOORS TO THE MULTIFLOW CABINET WERE BROKEN AND THE DOOR WAS SETTING ON THE DECK.
Recommendation: Repair the door.
Item No.: 33
Site: Galley-
Violation: THE BULKHEAD MOUNTED CLOCK WAS MISSING AND ONLY THE HOUSING WAS PRESENT MAKING THE AREA DIFFICULT TO CLEAN.
Recommendation: Replace the clock.
Item No.: 32
Site: Galley-DISHWASH AREA
Violation: FOOD WRAPPERS WERE NOTED IN THE WASTE RECEPTACLE AT THE HANDWASHING SINK.
Recommendation: Discontinue using uncovered, handwash station waste receptacles for disposing food wrappers.
Item No.: 21
Site: Buffet-HORIZON COURT AND CAFE CARIBE
Violation: THE SOLID SURFACE BUFFET COUNTERS WERE CRACKED IN NUMEROUS AREAS, ESPECIALLY AROUND THE HOT SERVICE AREAS. WARRANTY CLAIMS ARE STILL PENDING ON THESE COUNTERS.
Recommendation: Repair the damaged sections of the buffet counters.
Item No.: 32
Site: Buffet-HORIZON COURT
Violation: FOOD WASTE AND FOOD CONTAINER COVERS WERE NOTED IN THE AFT HANDWASHING STATION WASTE RECEPTACLES.
Recommendation: Discontinue using uncovered, handwash station waste receptacles for disposing food waste and food wrappers.
Item No.: 21
Site: Food Service General-TECHNICAL AREAS OF REFRIGERATION UNITS
Violation: THE BRINE CHILL WATER LINES TO THE REFRIGERATORS IN FOOD SERVICE AREAS AND THE BARS HAD GREEN OPEN CELL INSULATION WHICH WAS DIFFICULT TO CLEAN. IT APPEARED THAT EITHER THERE WERE LEAKS IN THE CHILL WATER SYSTEM OR THAT THE INSULATION WAS NOT SUFFICIENT BECAUSE THESE LINES WERE SOILED WITH MOLD.
Recommendation: Repair or replace the open cell insulation so it is easy to clean, and non-absorbent.
Item No.: 27
Site: Food Service General-TECHNICAL AREAS OF REFRIGERATION UNITS
Violation: THE GREEN FOAM INSULATION ON THE BRINE CHILL WATER LINES TO THE REFRIGERATORS IN THE GALLEYS, AND BARS WERE SOILED WITH PINK AND BLACK SLIME MOLD.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 41
Site: Children Area-DIAPER CHANGING STATION
Violation: THE DIAPER CHANGING STATION WASTE RECEPTACLE WAS NOT AIR-TIGHT. THIS WAS CORRECTED DURING THE INSPECTION.
Recommendation: Ensure that each station includes an airtight, soiled-diaper receptacle.
Item No.: 08
Site: Potable Water-SUITE 8750, DECK 12
Violation: THE AIR GAP ON THE PRIVATE WHIRLPOOL BATHTUB WAS LESS THAN THE REQUIRED TWO PIPE DIAMETERS, AND A BACKFLOW PREVENTION DEVICE COULD NOT BE LOCATED ON THE POTABLE WATER SUPPLY LINE.
Recommendation: Ensure that proper backflow protection is provided at the in cabin whirlpool bathtubs.
Item No.: 10
Site: Other-WHIRLPOOL RECORDS
Violation: THE MULTIPLE DAY CHARTS UTILIZED TO RECORD THE FREE HALOGENATION CONCENTRATION AND PH FOR THE WHIRLPOOLS DID NOT PROVIDE DETAILS REGARDING THE CONCENTRATION OR THE COLOR OF PEN UTILIZED FOR HALOGEN AND PH. THE STAFF COULD NOT PROVIDE THE INFORMATION ON WHAT EACH COLOR REPRESENTED NOR WERE THEY ABLE TO DETERMINE THE HALOGEN CONCENTRATION.
Recommendation: Ensure that the crew responsible for operating and maintaining the whirlpool spas are knowledgeable of the information recorded on the whirlpool spa charts and that the charts accurately Indicate halogen and pH levels of the spas.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program