|
Item No.:
01
|
Site:
Medical-MEDICAL
|
Violation:
A REVIEW OF SOME OF THE GASTROINTESTINAL ILLNESS SURVEILLANCE LOGS AND THE 24-HOUR AND 4-HOUR REPORTS INDICATED THAT THE MEDICAL STAFF REPORTED REPORTABLE AND NON-REPORTABLE CASES OF ILLNESS. IN ONE ROUTINE REPORT, THE NUMBER OF CASES AMONG PASSENGERS INCLUDED A CASE THAT WAS NOT GASTROINTESTINAL ILLNESS AND THEREFORE, WAS NOT A REPORTABLE CASE TO THE VSP.
|
Recommendation:
Include case counts for reportable cases of gastrointestinal illness only in the 24-hour and 4-hour surveillance reports.
|
|
Item No.:
06
|
Site:
Potable Water-MICROBIOLOGICAL TESTING
|
Violation:
THE SHIP BUNKERS POTABLE WATER REGULARLY IN NEW ORLEANS, BUT THE MOST RECENT MICROBIOLOGICAL ANALYSIS REPORT ONBOARD WAS AN ANNUAL SUMMARY OF WATER QUALITY FROM THE SEWERAGE AND WATER BOARD OF NEW ORLEANS FOR THE YEAR 2003. THE SHIP HAS AN ONBOARD MICROBIOLOGICAL TEST KIT WHICH IS APPROVED AND WILL PROVIDE ANALYSIS RESULT IN 24 HOURS, BUT IT IS ONLY USED FOR ANALYZING DISTRIBUTION SAMPLES FROM AREAS ON THE SHIP.
|
Recommendation:
Where available, ensure that the vessel has a copy of the most recent microbiologic report from each port before bunkering potable water to verify that the water meets potable standards.
In the case of unavailable recent reports for New Orleans or other ports, the ship should use the secondary option of conducting the E. coli test onboard with their existing test kit. For ports where the ship makes repeated sailings, the VSP considers one test per month, per port as a recent test.
|
|
Item No.:
07
|
Site:
Potable Water-DECK C ENGINE ROOM - AC COMPRESSOR ROOM
|
Violation:
THE HIGH SALINE OVERBOARD DISCHARGE LINES TO THE TWO EVAPORATORS WERE DOUBLE CHECK VALVE ASSEMBLY BACKFLOW PREVENTERS WITHOUT ATMOSPHERIC VENTS.
|
Recommendation:
Replace the double check valve backflow preventers with reduced pressure assembly backflow preventers.
|
|
Item No.:
08
|
Site:
Potable Water-DECK 0 CREW LAUNDERETTE
|
Violation:
THE 4 CLOTHES WASHERS ON THE FORWARD BULKHEAD IN THE LAUNDERETTE HAD NON-CONTINUOUS PRESSURE (8S MODEL) BACKFLOW PREVENTERS INSTALLED. IT WAS ALSO NOTED THAT AT LEAST SOME OF THE BACKFLOW PREVENTERS FROM THE ORIGINAL INSTALLATION MAY ALSO HAVE BEEN OF A NON-CONTINUOUS PRESSURE TYPE (NLF9 MODEL) ON THE OTHER WASHING MACHINES.
|
Recommendation:
Replace the backflow preventers with continuous pressure backflow preventers.
|
|
Item No.:
08
|
Site:
Potable Water-DECK 11 BEAUTY SALON, CREW AND PASSENGER LAUNDERETTES
|
Violation:
SOME OF THE BACKFLOW PREVENTION DEVICES INSTALLED ON THE SPRAY RINSE SINKS, WHIRPOOL FOOT BATH, AND CLOTHES WASHING MACHINES WERE NON-CONTINUOUS PRESSURE DEVICES (MODEL NLF9). IN EACH CASE THESE PREVENTERS WERE INSTALLED IN CONTINUOUS PRESSURE POSITIONS OF THE POTABLE WATER SUPPLY LINES. ADDITIONALLY, SOME OF THE DEVICES IDENTIFIED IN THE INSPECTION AND THE AIR-GAP PREVENTION PRESENTED IN VARIOUS APPLICATIONS (MINERALIZERS AND FILL LINE FROM EVAPORATORS TO POTABLE WATER).
|
Recommendation:
The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present:
(1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
|
|
Item No.:
16
|
Site:
Buffet-LIDO - CEZANNE GALLEY - COLD PANTRY
|
Violation:
WALK-IN REFRIGERATOR #49 WAS POSTED WITH A TIME CONTROL PLAN AND STAFF STATED THAT ALL ITEMS HELD WITHIN WERE ON TIME ONLY AS A PUBLIC HEALTH CONTROL. THE TIME CONTROL PLAN SHEETS WERE COMBINATION PLAN AND TIME/TEMPERATURE LOG FORMS, BUT IN THE DESCRIPTION OF ITEMS UNDER CONTROL THE CREAM CHEESE, DELI MEATS, CUBED MELONS, AND WEDGE MELONS WERE LISTED WITH PLAN ELEMENTS. IN EACH CASE THE FOOD WAS LISTED AS IN STORAGE AT 41 °F UNTIL REMOVED TO BE PLACED ON THE SELF-SERVICE BUFFET LINE (APPROXIMATELY 15 MINUTES PRIOR TO SERVICE). WHEN REMOVED THE ITEMS WOULD BE PLACED ON TIME CONTROL. THE LOG SECTION OF THE TIME CONTROL PLAN LISTED A TIME CONTROL PERIOD OF 6 AM TO DISCARD AT 10 AM. ANOTHER PLAN FOR HACCP ON THE SAME ITEMS REVEALED A SIMILAR DESIGN, WHERE AFTER RECEIPT (TEMPERATURE CONTROLLED) FOODS WOULD BE PREPARED IN SMALL BATCHES, AND HELD UNDER TEMPERATURE CONTROL UNTIL PLACED OUT FOR SERVICE (TIME CONTROL BEGINS AT THE TIME FOODS WERE PLACED FOR SERVICE). THE WALK-IN CONTAINED 4 TROLLEYS FILLED WITH WEDGE CUT CANTALOUPE MELONS, A LARGE PLASTIC BIN HALF-FILLED WITH CREAM CHEESE, 4 TRAYS OF CUT CHEESE AND VARIOUS DELI MEATS, AND APPROXIMATELY 8 LARGE PANS FILLED WITH CUBE CUT HONEYDEW AND CANTALOUPE MELONS. ALL THE INDIVIDUAL CONTAINERS OF FOOD INSIDE WALK-IN REFRIGERATOR #49 HAD TIME LABELS AFFIXED WHICH LISTED PREPARATION DATE OF 16 APRIL AND DISCARD DATES OF 23 APRIL.
|
Recommendation:
Using a walk-in refrigerator for a time only control system requires a detailed, written time control plan, with clearly detailed steps from preparation, cooling, transport, storage, and service. Temperature control must be documented and the point of time control should be labeled on the containers, as well as their discard time. Revise the written plan and all labels and log forms to be very specific about the potentially hazardous foods which will be stored in walk-in refrigerator #49.
|
|
Item No.:
19
|
Site:
Buffet-STAFF MESS - SELF-SERVICE BUFFET
|
Violation:
THE SMALL, SELF-SERVICE SOUP KETTLE WAS OUTSIDE THE SNEEZE GUARD AND THE SOUP WAS UNPROTECTED FROM POTENTIAL CONTAMINATION FROM STAFF DURING SERVICE.
|
Recommendation:
Provide a protective covering or sneeze guard for the soup kettle.
|
|
Item No.:
20
|
Site:
Buffet-LIDO - CEZANNE GALLEY - BUFFET PANTRY
|
Violation:
THREE LARGE PANS FILLED WITH CUBE CUT CANTALOUPE AND HONEYDEW MELONS HAD INTERNAL TEMPERATURES BETWEEN 45 AND 50 °F. THE PANS WERE REMOVED AND BLAST CHILLED. SEVERAL OTHER TROLLEYS AND PANS OF MELON, CREAM CHEESE, AND DELI MEATS/CHEESES WERE AT PROPER TEMPERATURE.
|
Recommendation:
Ensure that equipment for cooling and heating food, and holding cold and hot food, is sufficient in number and capacity to maintain specified potentially hazardous food temperatures.
|
|
Item No.:
20
|
Site:
Galley-CREW GALLEY
|
Violation:
THE INTERIOR OF THE BLADE COVER TO THE BUFFALO CHOPPER WAS SCORED AND GOUGED, MAKING CLEANING DIFFICULT.
|
Recommendation:
Adjust the blade on the buffalo chopper to prevent it from striking the lid when it is in operation. Smooth down the surfaces of the lid to return it to its easily cleanable characteristic.
|
|
Item No.:
21
|
Site:
Other-CREW MESS - SERVICE LINE
|
Violation:
THE DOOR TO THE UNDERCOUNTER CABINET DID NOT CLOSE PROPERLY.
|
Recommendation:
Make the necessary adjustments to the door so that it closes properly.
|
|
Item No.:
21
|
Site:
Other-CREW MESS - SERVICE LINE
|
Violation:
THE LABEL ON THE VITALITY JUICE MACHINE WAS PEELING, MAKING CLEANING DIFFICULT.
|
Recommendation:
Reattach or replace the peeling label on the juice dispenser.
|
|
Item No.:
21
|
Site:
Galley-MAIN GALLEY - MONET WINE PANTRY
|
Violation:
ONE WINE CHILLER WAS DAMAGED ON THE INTERIOR, MAKING CLEANING DIFFICULT.
|
Recommendation:
Replace damaged wine chiller.
|
|
Item No.:
21
|
Site:
Galley-MAIN GALLEY - CENTER GALLEY (FWD)
|
Violation:
THE GASKET AROUND THE WINDOWS ON THE DOORS OF 3 OF 6 COMBI-THERM OVENS WAS DAMAGED, MAKING CLEANING DIFFICULT.
|
Recommendation:
Repair or replace damaged gaskets.
|
|
Item No.:
21
|
Site:
Galley-MAIN GALLEY - CENTER GALLEY (FWD)
|
Violation:
A SCREW WAS MISSING FROM THE HINGE ON THE LID OF THE STEAM KETTLE LEAVING A LOOSE PANEL AND A LARGE OPENING, MAKING CLEANING DIFFICULT.
|
Recommendation:
Replace missing screw and reattach hinge to close the openings in this equipment.
|
|
Item No.:
21
|
Site:
Galley-MAIN GALLEY - BAKERY
|
Violation:
THE METAL SAFETY LABEL ON THE HOBART MIXER HAD GAPS AROUND THE LABEL WHERE FOOD AND DEBRIS COULD COLLECT, MAKING CLEANING DIFFICULT.
|
Recommendation:
Reattach the safety label in a manner that prevents the collection of food and debris.
|
|
Item No.:
21
|
Site:
Galley-MAIN GALLEY - RENOIR DISHWASH AREA
|
Violation:
SEVERAL LARGE SERVING TRAYS WERE DAMAGED ALONG THE EDGES, MAKING CLEANING DIFFICULT.
|
Recommendation:
Replace the damaged serving trays.
|
|
Item No.:
21
|
Site:
Galley-LIDO - CEZANNE GALLEY - DISHWASH
|
Violation:
SEVERAL OF THE COLORED SELF-SERVICE TRAYS STACKED ON THE CLEAN STORAGE SHELF HAD BROKEN AND CHIPPED EDGES, REVEALING A DIFFICULT TO CLEAN UNDERLAYER.
|
Recommendation:
Replace trays when the damage displayed clearly makes them difficult to clean.
|
|
Item No.:
22
|
Site:
Galley-LIDO - CEZANNE GALLEY - DISHWASH
|
Violation:
THE IN-USE CONVEYOR DISHWASH MACHINE HAD A FINAL RINSE COMPARTMENT WITH THE MIDDLE RINSE ARM SPRAY NOZZLES CREATING A WEAK, NARROW SPRAY PATTERN WHICH DIDN'T EFFECTIVELY COVER THE DISHWARE BELOW. ADDITIONALLY, THE FINAL UPPER SPRAY ARM HAD ONLY 5 OF THE 7 SPRAY NOZZLES PRODUCING WATER SPRAY.
|
Recommendation:
Ensure that warewashing equipment is maintained in good repair and proper adjustment including: (1) Being maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; and (2) Maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
|
|
Item No.:
22
|
Site:
Galley-MAIN GALLEY - POTWASH
|
Violation:
NINE OF 10 RINSE SPRAY NOZZLES ON THE IN-USE MECHANICAL POTWASH WERE NOT WORKING. THE TENTH SPRAY NOZZLE HAD AN ERRATIC SPRAY PATTERN.
|
Recommendation:
Ensure that warewashing equipment is maintained in good repair and proper adjustment including: (1) Being maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; and (2) Maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
|
|
Item No.:
26
|
Site:
Galley-MAIN GALLEY - SERVICE LINE
|
Violation:
THE INTERIOR OF ONE OF THE PREVIOUSLY CLEANED UNDERCOUNTER OVENS WAS SOILED.
|
Recommendation:
Clean soiled oven.
|
|
Item No.:
26
|
Site:
Galley-MAIN GALLEY - SALAD APPETIZER PANTRY
|
Violation:
A FEW PREVIOUSLY CLEANED PLATES WERE FOUND SOILED AND STORED AS CLEAN.
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
Item No.:
27
|
Site:
Galley-MAIN GALLEY - MONET WINE PANTRY
|
Violation:
SIX WINE CHILLERS WERE SOILED.
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
Item No.:
27
|
Site:
Galley-MAIN GALLEY - CENTER GALLEY (FWD)
|
Violation:
THE GREASE DRAINS TO THE PREVIOUSLY CLEANED DEEP FAT FRYERS WERE SOILED.
|
Recommendation:
Clean grease drains.
|
|
Item No.:
27
|
Site:
Galley-MAIN GALLEY - PASTRY
|
Violation:
SIX PREVIOUSLY CLEANED SHOW PLATES WERE FOUND SOILED AND STORED IN THE UNDERCOUNTER STORAGE CABINET.
|
Recommendation:
Ensure show plates are cleaned before placing into storage areas.
|
|
Item No.:
27
|
Site:
Other-DINING ROOM - MONET DINING ROOM (LOWER LEVEL)
|
Violation:
THE EXTERIOR OF ONE OF THE COFFEE GRINDERS AT THE BEVERAGE STATION WAS SOILED WITH GREATER THAN ONE DAY'S DIRT AND DEBRIS.
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
Item No.:
27
|
Site:
Other-DINING ROOM - MONET DINING ROOM (LOWER LEVEL)
|
Violation:
THE AREA ABOVE THE MILK FROTHING TUBE ON THE CAPPUCCINO MACHINE WAS SOILED. THIS MACHINE HAD BEEN PREVIOUSLY CLEANED.
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
Item No.:
27
|
Site:
Galley-CREW GALLEY
|
Violation:
THE GREASE DRAIN TUBE OF THE PREVIOUSLY CLEANED DEEP FAT FRYERS WERE SOILED WITH A HEAVY ACCUMULATION OF GREASE AND FOOD DEBRIS.
|
Recommendation:
Clean the soiled grease drain tube.
|
|
Item No.:
27
|
Site:
Galley-CREW GALLEY
|
Violation:
THE EXTERIOR OF THE PASS-THROUGH REFRIGERATOR WAS SOILED WITH GREATER THAN ONE DAY'S DIRT AND DEBRIS.
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
Item No.:
27
|
Site:
Buffet-LIDO - CEZANNE GRAND CENTER AND FORWARD BUFFETS
|
Violation:
THE PORT SIDE UNDERCOUNTER REACH-IN REFRIGERATOR DOOR GASKETS APPEARED SOILED OR STAINED WITH A BLACK MOLD RESIDUE IN THE CENTER BUFFET SECTION. NEARLY ALL THE DOOR GASKETS ON THE UNDERCOUNTER REFRIGERATORS WERE SOILED OR STAINED IN THE FORWARD BUFFET SECTION.
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
Item No.:
27
|
Site:
Galley-MAIN GALLEY - FORWARD - PORT
|
Violation:
THE PREVIOUSLY CLEANED COMMERCIAL TOASTER WAS SLIGHTLY SOILED WITH FOOD RESIDUE. THIS ITEM IS NOT BEING USED BY GALLEY PERSONNEL.
|
Recommendation:
Clean the commercial toaster and maintain clean or remove it from the space.
|
|
Item No.:
33
|
Site:
Galley-MAIN GALLEY - POTWASH
|
Violation:
BROKEN DECK TILES WERE NOTED AROUND THE DECK SCUPPERS.
|
Recommendation:
Repair broken deck tiles.
|
|
Item No.:
33
|
Site:
Bar-SKY BAR
|
Violation:
THE DECKHEAD IN THE FRONT BAR AREA WAS SOILED WITH A DIRT RESIDUE.
|
Recommendation:
Clean the deckhead regularly.
|
|
Item No.:
33
|
Site:
Buffet-LIDO - CEZANNE GRAND BUFFET
|
Violation:
THERE WAS A MOLD DEBRIS NOTED ALONG THE DECK COVING DIRECTLY BENEATH THE COUNTER IN THE CENTER SECTION OF THE WORKING SIDE OF THE BUFFET. SOME OF THE UTILITY LINES BENEATH THE COUNTER WERE ALSO HEAVILY SOILED WITH THE MOLDY DEBRIS.
|
Recommendation:
Clean the cove base section of the deck more thoroughly to prevent the build-up of mold residue and other dirty debris.
|
|
Item No.:
33
|
Site:
Other-DINING ROOM - MONET DINING ROOM (UPPER LEVEL)
|
Violation:
THE DECKHEAD ABOVE THE STBD BEVERAGE STATION DRINK PREPARATION COUNTER WAS SOILED.
|
Recommendation:
Clean the soiled deckhead.
|
|
Item No.:
33
|
Site:
Galley-MAIN GALLEY - PASTRY
|
Violation:
RECESSED GROUT WAS NOTED BETWEEN DECK TILES IN THIS AREA.
|
Recommendation:
Repair recessed grout between deck tiles.
|
|
Item No.:
33
|
Site:
Provisions-PROVISIONS - FRUIT WALK-IN REFRIGERATION UNIT
|
Violation:
GROUT WAS MISSING BETWEEN DECK TILES IN THIS AREA. THIS ITEM IS SCHEDULED FOR CORRECTIVE ACTION DURING THE AUGUST, 2005 DRYDOCK PERIOD.
|
Recommendation:
Repair missing grout at the upcoming drydock period or sooner.
|
|
Item No.:
33
|
Site:
Provisions-PROVISIONS - VEGETABLE WALK-IN REFRIGERATION UNIT
|
Violation:
THE METAL DECK WAS SEPARATING FROM THE FOUNDATION, LEAVING A LARGE AREA OPEN FOR DIRT AND DEBRIS TO COLLECT, MAKING CLEANING DIFFICULT. THE DECK IN THIS AREA WAS ALSO SOILED WITH FOOD AND DIRT. SEVERAL BROKEN DECK TILES WERE ALSO NOTED IN THIS AREA. THESE ITEMS ARE SCHEDULED FOR CORRECTIVE ACTION DURING THE AUGUST, 2005 DRYDOCK PERIOD.
|
Recommendation:
Reattach the metal deck to the foundation. Clean the deck regularly to prevent food and dirt accumulation. Repair broken deck tiles.
|
|
Item No.:
33
|
Site:
Provisions-PROVISIONS - ICE CREAM FREEZER
|
Violation:
MISSING DECK TILES WERE NOTED AT THE THRESHOLD OF THIS UNIT. THE DECK WAS ALSO SOILED.
|
Recommendation:
Replace missing deck tiles. Clean the deck regularly to prevent accumulation of dirt.
|
|
Item No.:
34
|
Site:
Galley-MAIN GALLEY - CENTER GALLEY (FWD)
|
Violation:
A CLOGGED DECK DRAIN WAS NOTED NEXT TO THE TILTING PANS. THIS ITEM WAS CORRECTED DURING THE INSPECTION.
|
Recommendation:
Ensure that a plumbing system in a food area is maintained in good repair.
|
|
Item No.:
36
|
Site:
Bar-CAFE' FANS AND ATRIUM BARS
|
Violation:
THE LIGHT BULBS OVER THE FRONT BAR COUNTER IN CAFE' FANS WERE NOT EFFECTIVELY SHIELDED FROM BELOW AND WERE NOT SHATTER-RESISTANT BULBS. THE DOUBLE BULB LIGHT FIXTURES OVER THE BAR AND BACK BAR SECTIONS OF THE ATRIUM BAR WERE NOT SHIELDED OR SHATTER-RESISTANT BULBS.
|
Recommendation:
Ensure that light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
|
|
Item No.:
39
|
Site:
Other-DINING ROOM - MONET DINING ROOM (UPPER LEVEL)
|
Violation:
TWO LIVE FRUIT FLIES WERE NOTED IN THE BEVERAGE STATION AREA.
|
Recommendation:
Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
|
|