Item No.:
02
|
|
Site:
Medical-GI LOGS
|
|
Violation:
SOME GASTROINTESTINAL ILLNESS LOGS WERE MISSING CASE-PATIENT DATA ELEMENTS.
|
|
Recommendation:
The gastrointestinal illness surveillance log entry for each passenger or crew member shall contain the following information:
(1) The first date of clinic visit or report to staff of illness; (2) The person's name, age and gender; (3) A designation as passenger or crew member; (4) Crew member position or job on the vessel, if applicable; (5) Cabin number; (6) Meal seating information; (7) Date and time of illness onset; (8) Illness symptoms, including the presence of the following selected signs and symptoms: numbers of episodes each of diarrhea and vomiting per day, bloody stools, fever, recorded temperature; (9) Notation on whether or not a stool specimen was requested and received; (10) Use of antidiarrheal medication; and (11) The presence of underlying medical conditions which may affect interpretation of acute gastrointestinal illness for example diabetic diarrhea, inflammatory bowel disease, gastrectomy or others.
|
|
|
Item No.:
25
|
|
Site:
Galley-MAIN GALLEY
|
|
Violation:
WET WIPING CLOTHES WERE NOTED STORED ON THE COUNTERTOPS OUTSIDE THE SANITIZER CONTAINERS.
|
|
Recommendation:
Store wiping cloths in a sanitizing solution when not in active use.
|
|
|
Item No.:
26
|
|
Site:
Galley-MAIN GALLEY
|
|
Violation:
NUMEROUS PREVIOUSLY CLEANED PLATES, SAUCERS, SAUCE PANS AND UTENSILS WAS FOUND SOILED AND STORED IN THE CLEAN STORAGE CABINETS
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
28
|
|
Site:
Galley-MAIN GALLEY
|
|
Violation:
CLEAN ARTICLES, SUCH AS PLATES, SAUCERS, PANS AND SERVING UTENSILS, WERE STORED IN SOILED STORAGE AREAS.
|
|
Recommendation:
Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
27
|
|
Site:
Galley-MAIN GALLEY
|
|
Violation:
SEVERAL STORAGE AREAS WERE SOILED WITH OLD FOOD DEBRIS.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
21
|
|
Site:
Galley-MAIN GALLEY
|
|
Violation:
SOME NON-FOOD-CONTACT SURFACES, SUCH AS THE FLAT-TOP GRILL AREA, HAD GAPS, SEAMS AND PEELING LABELS, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Galley-MAIN GALLEY
|
|
Violation:
THE GAP BETWEEN THE FLAT-TOP GRILL WAS SOILED WITH A LARGE AMOUNT OF FOOD DEBRIS. THE FOOD DEBRIS APPEARED TO BE GREATER THAN ONE DAY'S ACCUMULATION.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
26
|
|
Site:
Galley-MAIN GALLEY
|
|
Violation:
THE INSIDE OF THE UNDERCOUNTER OVEN WAS SOILED WITH GREATER THAN ONE DAY'S FOOD DEBRIS.
|
|
Recommendation:
Ensure that the food-contact surfaces of cooking equipment and pans are kept free of encrusted grease deposits and other soil accumulations.
|
|
|
Item No.:
27
|
|
Site:
Galley-MAIN GALLEY
|
|
Violation:
THE PIPING BEHIND THE COUNTERTOP OVEN WAS SOILED WITH GREATER THAN ONE DAY'S FOOD DEBRIS.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
33
|
|
Site:
Galley-MAIN GALLEY
|
|
Violation:
DECKHEAD PANELS WERE OBSERVED LOOSE OR MISSING, MAKING CLEANING DIFFICULT. BULKHEADS HAD PIPE PENETRATIONS AND OTHER FEATURES THAT MAKE CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Provisions-DRY STORAGE
|
|
Violation:
THE DECK WAS SOILED WITH PAPER AND FOOD ITEMS.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
19
|
|
Site:
Provisions-MEAT FREEZER
|
|
Violation:
BOXED FOOD ITEMS WERE FOUND STORED DIRECTLY ON THE DECK.
|
|
Recommendation:
Ensure that food is protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
26
|
|
Site:
Bar-BAR
|
|
Violation:
A PREVIOUSLY CLEANED STAINLESS STEEL COFFEE MUG WAS FOUND SOILED AND STORED AS CLEAN.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
24
|
|
Site:
Bar-BAR
|
|
Violation:
THE HALOGEN CONCENTRATION IN THE SANITIZER CONTAINER WAS MEASURED AT GREATER THAN 200 PPM.
|
|
Recommendation:
Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
|
|
|
Item No.:
27
|
|
Site:
Other-DINING ROOM
|
|
Violation:
THE TOPS OF THE COFFEE DISPENSER WAS FOUND SOILED WITH COFFEE GROUNDS.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-SHOWERS
|
|
Violation:
THE FLEXIBLE SHOWER HOSES IN THE CABINS WERE NOT FITTED WITH A BACKFLOW PREVENTION DEVICES.
|
|
Recommendation:
Install appropriate backflow protection on the flexible shower hoses.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-ENGINE ROOM
|
|
Violation:
A HOSE IN THE ENGINE ROOM WAS FOUND FITTED WITH A NON-CONTINUOUS PRESSURE BACKFLOW PREVENTION DEVICE WITH A NOZZLE ON THE END.
|
|
Recommendation:
Install a continuous pressure type backflow prevention device on the spigot.
|
|
|
Item No.:
20
|
|
Site:
Food Service General-
|
|
Violation:
THE FOOD CONTACT SURFACES OF THE OLDER EQUIPMENT HAD GAPS, SEAMS, HOLES, AND OTHER DIFFICULT TO CLEAN FEATURES.
MANY OF THESE ITEMS SHOULD BE CORRECTED DURING THE UPCOMING GALLEY RENOVATIONS.
|
|
Recommendation:
Ensure that multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
*
|
|
Site:
Food Service General-
|
|
Violation:
THE VESSEL IS SCHEDULED FOR A MAJOR RENOVATION WHICH SHOULD IMPROVE THE OVERALL SANITATION AND ABILITY TO CLEAN THE FOOD SERVICE AREAS. THE DRY DOCK IS SCHEDULED FOR NOVEMBER 2005.
|
|
Recommendation:
|
|