Item No.:
19
|
|
Site:
Galley-MAIN GALLEY - DECK 5 - DINING ROOM LOCKER
|
|
Violation:
TWO BOXES OF PLATES AND CUPS WERE NOT STORED A MINIMUM OF 15 CENTIMETERS (6 INCHES) ABOVE THE DECK.
|
|
Recommendation:
Ensure that food is protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
33
|
|
Site:
Galley-MAIN GALLEY - DECK 5 - SAUCE PREPARATION
|
|
Violation:
THE DECK UNDER DEEP FAT FRYER G28 WAS SOILED WITH A PIECE OF MEAT. THIS AREA WAS CLEANED EARLIER IN THE DAY.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
26
|
|
Site:
Galley-MAIN GALLEY - DECK 6 - PLATE STORAGE AREA
|
|
Violation:
FOUR PREVIOUSLY CLEANED PLATES WERE FOUND SOILED AND STORED AS CLEAN.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Galley-MAIN GALLEY - DECK 6 - WINE STORAGE (AFT)
|
|
Violation:
ONE PREVIOUSLY CLEANED BAR GLASS WAS FOUND SOILED AND STORED AS CLEAN.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
30
|
|
Site:
Galley-MAIN GALLEY - DECK 6 - CENTER GALLEY
|
|
Violation:
THE 'WASH HANDS OFTEN' SIGN WAS MISSING AT THE HANDWASH STATION. THIS ITEM WAS CORRECTED DURING THE INSPECTION.
|
|
Recommendation:
Ensure that a sign stating "WASH HANDS OFTEN" in a language that the food employees understand is posted over handwashing sinks.
|
|
|
Item No.:
26
|
|
Site:
Galley-MAIN GALLEY - DECK 6 - WINE STATION (FWD)
|
|
Violation:
ONE SOILED BAR GLASS WAS FOUND SOILED AND STORED AS CLEAN.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
33
|
|
Site:
Galley-CREW GALLEY
|
|
Violation:
THE DECK WAS SOILED AT THE THRESHOLD TO THE CREW BUFFET AREA. THIS AREA WAS CLEANED EARLIER IN THE DAY. THIS ITEM WAS CORRECTED DURING THE INSPECTION.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
24
|
|
Site:
Galley-CREW GALLEY - POTWASH AREA
|
|
Violation:
THE FINAL RINSE TEMPERATURE ON THE IN-USE MECHANICAL POTWASH WAS MEASURED ON THREE SEPARATE OCCASIONS AT 148-150°F AT APPROXIMATELY 1645. THE TEMPERATURE LOGS INDICATED THE FINAL RINSE TEMPERATURE WAS MEASURED AT 184°F AT NOON. UPON INVESTIGATION, IT WAS FOUND THAT THE FINAL RINSE SPRAY ARMS WERE NOT PROVIDING PROPER COVERAGE DUE TO A MISSING RUBBER PLUG. THE RUBBER PLUG WAS LOCATED AND REINSERTED.
|
|
Recommendation:
In a mechanical operation, ensure that the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F), or less than: (1) For a stationary rack, single temperature machine, 74°C (165°F); or (2) For all other machines, 82°C (180°F); or (3) A utensil surface temperature of 71°C (160°F) as measured by an irreversible registering temperature indicator shall be achieved. (4) The maximum temperature of 90°C (194°F), does not apply to the high pressure and temperature systems with wand-type, hand-held, spraying devices used for the in-place cleaning and sanitizing of equipment such as meat saws.
|
|
|
Item No.:
33
|
|
Site:
Provisions-PROVISIONS - FROZEN FISH FREEZER
|
|
Violation:
DECKHEAD PANELS WERE NOTED SEPARATING, MAKING CLEANING DIFFICULT. THIS ITEM IS SCHEDULED FOR REPAIR ON OR ABOUT 12 JUNE 2005.
|
|
Recommendation:
Repair or replace damaged, separating deckhead panels.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-AFT STARBOARD BUNKER STATION
|
|
Violation:
THE DISTILLATE TRANSFER LINE, USED TO TRANSFER DISTILLATE FROM THE VESSEL TO SHORE WAS PAINTED BLUE SIMILAR TO THE POTABLE WATER FILLING LINE. THE DISTILLATE TRANSFER LINE IN THE AFT PORTSIDE BUNKER STATION WAS PAINTED A BLUE AND WHITE COLOR AND STRIPED BLUE AND YELLOW DIFFERENTIATING IT FROM THE POTABLE WATER LINES.
THE HOSE FITTING WAS DIFFERENT FROM THE POTABLE WATER FILLING LINE CONNECTIONS DECREASING THE POTENTIAL FOR CONNECTION MISTAKES.
|
|
Recommendation:
Paint the distillate transfer line a different color than the potable water filling lines.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-GARBAGE SORTING ROOM AND INCINERATOR ROOM
|
|
Violation:
HOSES WITH SHUT-OFF VALVES WERE CONNECTED TO THE HOSE CONNECTIONS ON THE HANDWASHING STATIONS. ATMOSPHERIC VACUUM BREAKERS WERE PROVIDED AS THE BACKFLOW PREVENTERS.
|
|
Recommendation:
Install continuous pressure type backflow prevention devices.
|
|
|
Item No.:
20
|
|
Site:
Buffet-HORIZON COURT DECK 14
|
|
Violation:
A TRAY OF YOGURT AND A TRAY OF MILK CONTAINERS IN UNDERCOUNTER REFRIGERATOR 140610 WERE FOUND WITH INTERNAL PRODUCT TEMPERATURES OF 45° F. THE MOUNTED AND INTERNAL AMBIENT THERMOMETERS WERE READING 48° F.
THE DAIRY PRODUCTS HAD COME FROM THE DECK 12 HORIZON COURT GALLEY WHERE THE PRODUCT TEMPERATURES WERE CHECKED AND THE TEMPERATURES WERE AT 38° F.
THE SOUS CHEF FOR THE AREA CHOSE TO DISCARD THE PRODUCT BUT COULD HAVE BLAST CHILLED IT DOWN TO 41° F.
|
|
Recommendation:
Ensure that the refrigerators are able to maintain food temperatures at or below 41°F.
|
|
|
Item No.:
20
|
|
Site:
Galley-HORIZON COURT GALLEY DECK 12
|
|
Violation:
THE TWO STEAM KETTLES WERE POSTED OUT OF ORDER AWAITING SPARE PARTS. THE TWO KETTLES HAD BEEN OUT OF ORDER FOR TWO WEEKS.
|
|
Recommendation:
Repair the kettles as soon as parts arrive.
|
|
|
Item No.:
33
|
|
Site:
Other-COLD ROOMS
|
|
Violation:
NUMEROUS BULKHEADS IN THE COLD ROOMS BOTH IN PROVISIONS AND IN GALLEYS HAD BEEN REPAIRED UNDER SHIPYARD WARRANTY BY USING NON-CORRODING HEX-HEAD FASTENERS TO RECONNECT THE STAINLESS STEEL SHEETING TO THE INSULATION. THIS REPAIR MADE THE BULKHEADS DIFFICULT TO CLEAN DUE TO THE EXPOSED FASTENERS.
|
|
Recommendation:
Use a method that does not require exposed hex-head fasteners to repair the bulkheads.
|
|