|
|
|
Item No.:
33
|
|
Site:
Galley-GALLEY
|
|
Violation:
THE EXPOSED BULKHEAD PANEL ABOVE THE REFRIGERATION UNITS WAS MADE OF WOOD AND WAS DIFFICULT TO CLEAN. THE ADJACENT LAMINATE PANEL WAS SEPARATING FROM THE SUBSTRATE, LEAVING A GAP, MAKING CLEANING DIFFICULT. PEELING WALLPAPER MATERIAL WAS NOTED ON THE SIDE OF THE COUNTER ADJACENT TO THE HANDWASH SINK.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
26
|
|
Site:
Galley-GALLEY
|
|
Violation:
SEVERAL PREVIOUSLY CLEANED BOWLS, COOKING PANS, UTENSILS AND FOOD CONTAINERS WERE FOUND SOILED AND STORED IN THE UNDERCOUNTER STORAGE AREAS.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
29
|
|
Site:
Galley-GALLEY
|
|
Violation:
THE DESIGN OF THE HANDWASH STATION DOES NOT PREVENT THE SPLASH FROM HANDWASHING ACTIVITIES FROM CONTAMINATING THE ADJACENT FOOD PREPARATION COUNTER.
|
|
Recommendation:
Install an easily cleanable barrier to prevent splash from handwashing activities to the adjacent food preparation counter.
|
|
|
Item No.:
38
|
|
Site:
Galley-GALLEY
|
|
Violation:
EXCESS GALLEY ITEMS WERE NOTED STORED ON THE TOPS OF THE REFRIGERATION UNITS. THESE ITEMS WERE CONSIDERED UNNECESSARY BY THE SHIP GALLEY STAFF.
|
|
Recommendation:
Remove excess materials from food preparation areas.
|
|
|
Item No.:
21
|
|
Site:
Galley-GALLEY
|
|
Violation:
THE REFRIGERATOR HANDLE WAS BROKEN.
|
|
Recommendation:
Repair the broken door handle.
|
|
|
Item No.:
33
|
|
Site:
Galley-GALLEY
|
|
Violation:
DRIED FOOD DEBRIS WAS NOTED ON THE DECKHEAD ABOVE THE STOVE AREA.
|
|
Recommendation:
Clean deckhead above stove area.
|
|
|
Item No.:
24
|
|
Site:
Galley-GALLEY
|
|
Violation:
THE SANITIZER SOLUTION CONCENTRATION IN THE SANITIZER BUCKET STAGED AT THE THREE-COMPARTMENT SINK EXCEEDED 200 PPM.
|
|
Recommendation:
Maintain sanitizer solutions between 50-200 ppm.
|
|
|
Item No.:
16
|
|
Site:
Galley-GALLEY
|
|
Violation:
LABELS AFFIXED TO POTENTIALLY HAZARDOUS FOODS, SUCH AS POTATO AND TUNA SALADS AND OPENED DELI MEATS, STORED IN THE REFRIGERATION UNITS DID NOT HAVE DISCARD DATES.
|
|
Recommendation:
Ensure that refrigerated, ready-to-eat, potentially hazardous food: (2) A container of refrigerated, ready-to-eat potentially hazardous food prepared and packaged by a food processing plant is clearly marked, at the time the original container is opened, to indicate the date by which the food shall be consumed which is, including the day the original container is opened, 7 calendar days or fewer after the original container is opened.
|
|
|
Item No.:
29
|
|
Site:
Bar-BAR
|
|
Violation:
THE HANDWASH SINK IN THIS AREA WAS BEING USED AS A DUMP SINK. THERE WAS EVIDENCE OF DISCARDED COFFEE IN THE SINK.
|
|
Recommendation:
Ensure that handwashing facilities are used for no other purpose and are accessible at all times.
|
|
|
Item No.:
20
|
|
Site:
Bar-BAR
|
|
Violation:
THE INTERNAL THERMOMETER WAS MISSING FROM THE UNDERCOUNTER REFRIGERATION UNIT. THE UNIT DID NOT HAVE A MOUNTED EXTERNAL THERMOMETER.
|
|
Recommendation:
Ensure that food temperature measuring devices are provided and readily accessible for use in ensuring attainment and maintenance of food temperatures.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-POTABLE WATER
|
|
Violation:
THERE WAS NO BACK-UP CHLORINATION PUMP WITH AUTOMATIC SWITCHOVER CAPABILITIES INSTALLED ON THE DISTRIBUTION HALOGENATION SYSTEM. THIS IS A REPEAT ITEM.
|
|
Recommendation:
Ensure that at least one backup halogen pump is available with automatic switchover to maintain the free residual halogen in the event that the primary pump fails.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-POTABLE WATER
|
|
Violation:
THERE WERE SEVERAL DAYS SINCE THE LAST INSPECTION WHERE THE HALOGEN (CHLORINE) RESIDUALS WERE LESS THAN 0.2 PPM FOR GREATER THAN 8 HOURS ON EACH DAY IN QUESTION. THERE WAS NO INDICATION ON EITHER THE HALOGEN ANALYZER CHARTS OR IN A LOGBOOK AS TO THE REASONS FOR THE LOW HALOGEN RESIDUALS.
|
|
Recommendation:
Ensure that records from the halogen analyzer-chart recorder verify the free residual halogen of 0.2 mg/L (ppm) and 5.0 mg/L (ppm) in the water distribution system for at least 16 hours in each 24-hour period since the last inspection of the vessel.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-POTABLE WATER
|
|
Violation:
NOTATIONS OF DAILY CALIBRATIONS WERE MISSING FROM THE DISTRIBUTION HALOGEN ANALYZER CHARTS AND WERE NOT DOCUMENTED ELSEWHERE.
|
|
Recommendation:
Ensure that the halogen analyzer-chart recorder is properly maintained, operated, and calibrated daily in accordance with the manufacturer's instructions.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-POTABLE WATER
|
|
Violation:
THE POTABLE WATER HOSE LOCKER WAS NOT LABELED.
|
|
Recommendation:
Ensure that potable water hose lockers are marked "POTABLE WATER HOSE AND FITTING STORAGE" in letters at least 13 mm (0.5 inch) high.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-POTABLE WATER
|
|
Violation:
A FEW ENTRIES IN THE POTABLE WATER PRODUCTION LOG LISTED THE TERM 'OKAY' IN THE COLUMN WHERE HALOGEN RESIDUALS WERE LISTED.
|
|
Recommendation:
Record the halogen concentrations and record in the potable water production logs.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-IPM
|
|
Violation:
THERE WAS NO DOCUMENTATION IN THE IPM PLAN OF PEST CONTROL TRAINING FOR DESIGNATED IPM PERSONNEL.
|
|
Recommendation:
Ensure that the training of the pest-control personnel is documented in the Integrated Pest Management Plan.
|
|