Cruise Ship: Coral Princess Cruise Line: Princess Cruises Inspection Date: 08/31/2005 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 02
Site: Medical-CLINICAL SPECIMEN SHIPPING
Violation: ALTHOUGH THE HOSPITAL WAS EQUIPPED WITH SUFFICIENT GASTROINTESTINAL CLINICAL SPECIMEN COLLECTION CONTAINERS, PROPER SHIPPING CONTAINERS AND LABELS FOR THE CONTAINERS WERE NOT AVAILABLE. THIS IS A NEW REQUIREMENT FROM THE VSP OPERATIONS MANUAL 2005.
Recommendation: Ensure that the medical department has the proper shipping containers and labels for same. Section 4.3.1 of the 2005 Vessel Sanitation Program Operations Manual. Specific information on vendors is provided at the VSP website.
Item No.: 08
Site: Potable Water-BUNKER CHLORINATION LOCKER
Violation: NOT ALL OF THE POTABLE WATER HOSES USED FOR BUNKERING HAD THE WORDS "POTABLE WATER ONLY" LABELED AT BOTH CONNECTING ENDS. THIS IS A REQUIREMENT FROM THE 2005 VSP OPERATIONS MANUAL.
Recommendation: Potable water hoses shall be labeled for use with the words "potable water only" in letters at least 13 mm (0.5 inch) at each connecting end.
Item No.: 09
Site: Recreational Water Facilities-LOTUS POOL - DECK 14
Violation: THIS POOL HAD WATER FEATURES IN TERMS OF WATER TEMPERATURE AND TURBULENCE SIMILAR TO A WHIRLPOOL SPA, BUT A WATER VOLUME OF A SWIMMING POOL. ACCORDING TO THE VSP OPERATIONS MANUAL 2005 THIS POOL MEETS THE DEFINITION OF A SPA POOL. THE FREE HALOGEN RESIDUAL WAS MAINTAINED AT 1.07 PPM CHLORINE DURING THE INSPECTION, AND STAFF STATED THIS POOL WAS NOT SHOCK CHLORINATED EACH NIGHT.
Recommendation: Ensure that swimming pools, with whirlpool spa features, are maintained at a free residual chlorine of >3.0 mg/L (ppm) and <10 mg/L (ppm), or a free residual bromine of >4.0 mg/L (ppm) and <10 mg/L (ppm). Additionally, ensure that the residual halogen level is increased to at least 10.0 mg/L (ppm) and circulated for at least 1 hour at the end of each day. Refer to sections 6.3.2.1.2 6.4.2 of the 2005 Vessel Sanitation Operation Manual.
Item No.: 16
Site: Food Service General-HORIZON COURT
Violation: THE FOOD PRODUCTION LABELS PLACED ON INDIVIDUAL CONTAINERS/TRAYS OF READY-TO-EAT POTENTIALLY HAZARDOUS FOODS (DELI MEATS, CUT MELONS, AND SLICED CHEESES) WERE LEFT ON THOSE PRODUCTS AFTER THEY WERE TRANSFERRED TO COLD HOLDING UNITS AND POSTED WITH TIME ONLY CONTROL LABELS (ON THE REFRIGERATOR EXTERIORS AND THE COUNTERS AT THE COLD TOP). THIS CREATED SOME CONFUSION, GIVEN THE PRODUCTION LABELS CALLED FOR DISCARD AFTER 24 OR 48 HOURS AND TIME ONLY CONTROL HAS A 4 HOUR LIMIT. ONCE PUT INTO A TIME CONTROL STORAGE ALL PRODUCTION LABELS SHOULD BE REMOVED.
Recommendation: Remove the 7 day discard production type labels when any ready-to-eat or potentially hazardous food is removed from temperature control and placed under time only as a control.
Item No.: 19
Site: Buffet-HORIZON COURT LIDO BUFFET
Violation: THE HOT SOUP AND OATMEAL ON THE PORT AND STARBOARD BUFFET SERVICE LINES FOR PASSENGER SELF-SERVICE WERE NOT PROVIDED WITH SNEEZE SHIELDS. THE SERVING CONTAINERS DID HAVE LIDS, BUT WHEN PASSENGERS SERVE THEMSELVES THE LIDS ARE REMOVED AND THE PRODUCTS SUBJECT TO CONTAMINATION.
Recommendation: Ensure that food on display is protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
Item No.: 21
Site: Food Service General-GALLEYS GENERAL
Violation: SEVERAL SERVICE TRAYS WERE FOUND WITH CHIPPED AND PEELING RESIN COATING MAKING CLEANING DIFFICULT.
Recommendation: Ensure that nonfood-contact surfaces of equipment and utensils are designed and constructed to be durable and to retain their characteristic qualities under normal use conditions.
Item No.: 21
Site: Galley-DECK 5 GRILL
Violation: THE COLD HOLDING REFRIGERATOR HAD PEELING TAPE ON THE DOOR EXTERIOR MAKING CLEANING DIFFICULT.
Recommendation: Ensure that nonfood-contact surfaces of equipment and utensils are designed and constructed to be durable and to retain their characteristic qualities under normal use conditions.
Item No.: 21
Site: Galley-DECK 4 AFT
Violation: THE COMBINATION OVEN'S LOWER INTERIOR DOOR SEAL WAS MISSING RESULTING IN CONDENSATE POOLING ON THE FLOOR.
Recommendation: Ensure that nonfood-contact equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 22
Site: Galley-POT WASH
Violation: THE FINAL RINSE GAUGE REGISTERED 130°F DURING ACTIVE USE OF THE POT WASH MACHINE. THE FINAL RINSE TEMPERATURE WAS MEASURED INTERNALLY AND RECORDED AT 170°F. THE GAUGE WAS REPLACED IMMEDIATELY.
Recommendation: Ensure that warewashing equipment is maintained in good repair and proper adjustment including: (1) Being maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; and (2) Maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
Item No.: 28
Site: Galley-DECK 12 GALLEY - POT WASH
Violation: THE STAFF MEMBER REMOVING SANITIZED POTS, PANS, AND UTENSILS FROM THE POT WASH MACHINE WAS DRYING THE ITEMS WITH A TOWEL BEFORE STACKING ON THE CLEAN STORAGE RACK.
Recommendation: After cleaning and sanitizing, ensure that equipment and utensils are air-dried or adequately drained before contact with food. Cleaned, sanitized, and air-dried dishware, glassware, and utensils may be polished with a clean, dry, lint-free cloth that is maintained clean and dry.
Item No.: 33
Site: Galley-DECK 5 SOUP STATION
Violation: THE DECK UNDER THE PREPARATION COUNTER WAS SOILED WITH GREASE AND OLD FOOD DEBRIS.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Galley-HORIZON COURT DISHWASH CORRIDOR
Violation: THE DIRTY DISH DROP CORRIDOR HAD A NUMBER OF CRACKED DECK TILES EVIDENT. STAFF STATED A WORK ORDER REQUEST WAS PENDING FOR THE REPAIR IN THIS AREA.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 37
Site: Galley-DECK 5 HOT SERVICE LINE
Violation: STEAM WAS EXITING THE FRONT EDGE OF THE CANOPY HOOD RESULTING IN CONDENSATE FORMING ON THE CANOPY EXTERIOR AND DECKHEAD.
Recommendation: Ensure that ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them.
Item No.: 39
Site: Galley-DECK 4 AFT BEVERAGE LINE
Violation: TWO TO THREE SMALL FLIES WERE NOTED IN THE DECK DRAIN UNDER THE COUNTER. NO FLIES WERE OBSERVED ABOVE THE DECK. A METAL FRAME HAD BEEN WELDED TO THE DECK AROUND THE DRAIN TO PREVENT SPLASH FROM THE WASTE LINE. THE FRAME HINDERED PROPER CLEANING OF THE DRAIN ALLOWING FOOD AND BEVERAGE SYRUP ACCUMULATION IN THE DRAIN.
Recommendation: Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
Item No.: 41
Site: Housekeeping-PUBLIC TOILETS
Violation: THE PAPER TOWEL DISPENSER AND WASTE RECEPTACLES IN THE PUBLIC TOILETS WERE LOCATED NEAR THE SINK, REQUIRING USERS TO USE BARE HANDS TO CONTACT THE DOOR HANDLE AND EXIT THE ROOM. THE 2005 VSP OPERATIONS MANUAL REQUIRES SOME METHOD BE USED TO ALLOW USERS TO EXIT THE ROOM WITHOUT BARE HAND CONTACT OF THE DOOR.
Recommendation: Per section 9.1.1.1.3 of the 2005 Vessel Sanitation Operations Manual, ensure that public toilets are equipped so that persons exiting the toilet room are not required to handle the door with bare hands. This may be accomplished by methods such as locating paper towel dispensers at sinks and waste containers near the room door, installing mechanically operated doors, door removal, or other effective means.