Item No.:
08
|
|
Site:
Potable Water-BUNKERING HOSES
|
|
Violation:
THE STANDARD GARDEN HOSES, UTILIZED FOR BUNKERING AT PORTS WITHOUT CONVENTIONAL POTABLE WATER BUNKERING CONNECTIONS, WERE NOT LABELED "POTABLE WATER ONLY".
|
|
Recommendation:
Potable water hoses shall be labeled for use with the words "potable water only" in letters at least 13mm (0.5 inch) at each connecting end.
|
|
|
Item No.:
27
|
|
Site:
Provisions-UPRIGHT FREEZER
|
|
Violation:
THE DOOR GASKET SEAMS HAD HEAVY MOLD GROWTH.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Provisions-UPRIGHT REFRIGERATOR
|
|
Violation:
THE DOOR GASKET SEAMS HAD HEAVY MOLD GROWTH.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
33
|
|
Site:
Provisions-
|
|
Violation:
SEVERAL DECK TILES WERE CHIPPED OR BROKEN MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Provisions-
|
|
Violation:
OLD FOOD MATTER AND OTHER DEBRIS WAS NOTED UNDER THE STORAGE RACKS AND EQUIPMENT.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
26
|
|
Site:
Provisions-
|
|
Violation:
SEVERAL PREVIOUSLY CLEANED PLASTIC BIN COVERS WERE FOUND SOILED.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
28
|
|
Site:
Provisions-
|
|
Violation:
SHEET PANS, USED FOR STORAGE OF CLEAN ITEMS, WERE FOUND SOILED.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
20
|
|
Site:
Provisions-
|
|
Violation:
PLASTIC BIN LIDS WERE FOUND WITH BROKEN CORNERS MAKING CLEANING DIFFICULT. THE LIDS WERE DISCARDED.
|
|
Recommendation:
Ensure that multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
33
|
|
Site:
Provisions-
|
|
Violation:
THE BULKHEADS HAD PIPE PENETRATIONS/RUNS AND OTHER FEATURES THAT MAKE CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that exposed utility service lines and pipes, including lines for fire detection and protection systems, are installed so they do not obstruct or prevent cleaning.
|
|
|
Item No.:
33
|
|
Site:
Galley-
|
|
Violation:
THE BULKHEADS HAD PIPE PENETRATIONS/RUNS AND OTHER FEATURES THAT MAKE CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that exposed utility service lines and pipes, including lines for fire detection and protection systems, are installed so they do not obstruct or prevent cleaning.
|
|
|
Item No.:
26
|
|
Site:
Bar-
|
|
Violation:
SEVERAL PREVIOUSLY CLEANED GLASSES WERE FOUND SOILED.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Bar-TECHNICAL AREA
|
|
Violation:
PIPING, HOSES, AND EQUIPMENT UNDER THE COUNTER WERE HEAVILY SOILED.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
*
|
|
Site:
Food Service General-
|
|
Violation:
MANY OF THE DESIGN AND EQUIPMENT RELATED ITEMS SHOULD BE ADDRESSED DURING THE NOVEMBER 2005 DRY DOCK.
|
|
Recommendation:
|
|
|
Item No.:
21
|
|
Site:
Galley-
|
|
Violation:
NON-FOOD CONTACT SURFACES OF THE DISHWASHER, STORAGE CABINETS, COUNTER BACKSPLASH, AND STATIONARY COOKING EQUIPMENT HAD GAPS, SEAMS, AND PEELING LABELS, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-ENGINE ROOM
|
|
Violation:
THE HOSE BIBB HAD A NON-CONTINUOUS PRESSURE BACKFLOW PREVENTION DEVICE. A SPRAY NOZZLE WAS ATTACHED TO THE HOSE.
|
|
Recommendation:
Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-AFT DECK GARBAGE AREA
|
|
Violation:
A HOSE WAS FOUND ATTACHED TO THE HOSE BIBB WITH NO BACKFLOW PREVENTION DEVICE. THE HOSE WAS FITTED WITH A SPRAY NOZZLE.
|
|
Recommendation:
Ensure that the potable water system is protected against backflow or other contamination by backflow preventers or air gaps.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-
|
|
Violation:
THERE WAS NO AUDIBLE ALARM TO INDICATE A LOW FREE HALOGEN RESIDUAL LEVEL. THIS IS A NEW REQUIREMENT FROM THE 2005 VESSEL SANITATION OPERATIONS MANUAL.
|
|
Recommendation:
Provide an audible alarm in a continuously occupied watch station, i.e.: the engine control room, o indicate low free halogen readings at the distant point (bridge) analyzer.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-
|
|
Violation:
SEVERAL ANALYZER CHARTS WERE FOUND WITH NO INITIALS.
|
|
Recommendation:
Ensure that halogen analyzer-chart recorder charts are changed, initialed, and dated daily and contain notations of any unusual water events in the potable water system.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-100 LEVEL DECK
|
|
Violation:
THE POTABLE WATER HOSE LOCKERS WERE MOUNTED DIRECTLY TO THE DECK. DECK WASHING ACTIVITIES ALLOWED WASH WATER AND DECK CLEANING REAGENTS TO POSSIBLY ENTER THE LOCKERS.
|
|
Recommendation:
Ensure that the potable water hose lockers are mounted at least 45 cm (18 inches) above the deck and are self-draining.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-100 LEVEL DECK
|
|
Violation:
STANDARD GARDEN HOSES WERE UTILIZED FOR BUNKERING POTABLE WATER AT PORTS WITH NO CONVENTIONAL BUNKERING CONNECTION.
|
|
Recommendation:
Ensure that all hoses, fittings, water filters, and appurtences used for connection with the bunkering of potable water are constructed of safe, easily cleanable materials.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-100 LEVEL DECK
|
|
Violation:
THE GARDEN HOSES USED FOR BUNKERING POTABLE WATER WERE NOT STORED WITH THE ENDS CAPPED OR OTHERWISE PROTECTED.
|
|
Recommendation:
Ensure that potable water hoses are stowed with the ends capped, on reels, or racks in potable water hose lockers.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-200 LEVEL DECK
|
|
Violation:
THE BUNKERING WATER LINE CAP WAS NOT PROPERLY SECURED. THE CAP'S CHAIN WAS ATTACHED TO THE BUNKER LINE UTILIZING A LIGHT WEIGHT STRING.
|
|
Recommendation:
Ensure that the potable water filling line has a screw cap or plug fastened by a non-corroding chain to an adjacent bulkhead or surface in such a manner that the cap or plug does not touch the deck when hanging free.
|
|
|
Item No.:
19
|
|
Site:
Buffet-DINING ROOM
|
|
Violation:
THE SNEEZE GUARD DID NOT PROVIDE PROTECTION FOR TRAYS OF FRESH FRUIT LOCATED AT THE END OF THE SERVICE LINE. ITEMS PLACED NEAR THE COUNTER EDGE WERE NOT COVERED BY THE SNEEZE GUARD. THREE CHAFING DISHES, UTILIZED FOR THE BREAKFAST BUFFET, WERE NOT PROTECTED BY SNEEZE GUARDS.
|
|
Recommendation:
Ensure that food on display is protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
|
|
|
Item No.:
20
|
|
Site:
Provisions-UPRIGHT FREEZER
|
|
Violation:
THE LOWER RUBBER DEFROST STRIP (INTERIOR), WAS CHIPPED MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that non-food contact equipment is maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
|
|