Cruise Ship: Silver Whisper Cruise Line: Silversea Inspection Date: 09/28/2005 Inspection Score: 99
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 10
Site: Recreational Water Facilities-SWIMMING POOL & WHIRLPOOLS
Violation: THE MONTHLY SAND FILTER SEDIMENTATION TEST WAS DONE IN A BUCKET AND NOT A CLEAR CONTAINER.
Recommendation: Ensure that the granular filters are opened at least monthly and examined for cracks, mounds, or holes in the filter media and a core sample of the filter media is inspected for excessive organic material accumulation using a recommended sedimentation method. One acceptable method is to draw water down to the media surface and inspect the granular filter for cracks, mounds, or holes, Take a sample from the filter core and inspect it for excessive organic/dirt build-up at least monthly. Shake sampled media and water in a clean, stoppered, clear plastic container and observe the settling action. If, after 30 minutes of settling, a measurable layer of sediment is within or on top of the filter media or fine, colored particles are suspended in the water, the organic loading may be excessive, and media replacement should be considered.
Item No.: 10
Site: Recreational Water Facilities-
Violation: THE FREE RESIDUAL CHLORINE LEVEL AND CONTACT TIME IN THE VESSEL'S FECAL ACCIDENT RESPONSE PROCEDURE FOR DISINFECTION OF THE POOL FOLLOWING A FECAL ACCIDENT (50 PPM FOR 1 HOUR) WAS NOT ADEQUATE FOR A FECAL ACCIDENT INVOLVING A LOOSE STOOL.
Recommendation: 6.2.1.2.2 Ensure that the vessel has a fecal accident response procedure which meets or exceeds the procedure provided in annex 13.11 of the August 2005 VSP Operations Manual and is documented and available to the VSP for review during inspections.
Item No.: 08
Site: Potable Water-
Violation: THE DOCUMENTATION FOR THE DISINFECTION OF THE POTABLE WATER TANKS DID NOT INCLUDE FLUSHING TO 5 PPM OR BELOW PRIOR TO PLACING THE TANK BACK INTO SERVICE.
Recommendation: Ensure that the disinfected parts of the system are flushed with potable water or otherwise dechlorinated until the free residual halogen is 5.00 mg/L (ppm) or below.
Item No.: 08
Site: Potable Water-
Violation: THE LISTING OF CROSS CONNECTIONS TO THE POTABLE WATER SYSTEM THAT IS PART OF THE COMPREHENSIVE CROSS CONNECTION CONTROL PROGRAM DID NOT CONTAIN THE AIR GAPS FOR THE WHIRLPOOL AND SWIMMING POOL MAKE-UP TANKS.
Recommendation: 5.7.1.1.4 Ensure that the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so there is a match to the plumbing system component and location, the program shall set a schedule for inspection frequency. Repeat devices such as toilets can be grouped under a single device type, and air-gaps shall be included in the listing. A log documenting the inspection or maintenance in written or electronic form shall be maintained and be available for review during inspections.
Item No.: 27
Site: Pantry-DECK 7 & 8 ICE PANTRIES
Violation: THE SURFACE BELOW THE CUBER IN THE UPPER COMPARTMENT OF THE ICE MACHINES WAS LIGHTLY SOILED WITH DUST.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris. Increase the cleaning frequency of the upper compartment of the ice machines onboard the vessel.
Item No.: 41
Site: Housekeeping-
Violation: MIKRO-BAC IS USED ONBOARD TO CLEAN SURFACES WHEN CREW OR PASSENGERS HAVE GASTROINTESTINAL ILLNESS. THE USE OF MIKRO-BAC IS NOT INDICATED IN THE VESSEL'S OUTBREAK PREVENTION AND RESPONSE PLAN.
Recommendation: 9.1.1.1.2 Ensure that the vessel has a written Outbreak Prevention and Response Plan (OPRP) which details the standard procedures and policies to specifically address gastrointestinal illness onboard. The written OPRP shall include at a minimum, the following: (a) Duties and responsibilities of each department and their staff (b) Steps in outbreak management and control and the trigger for each step.
Item No.: 41
Site: Housekeeping-
Violation: THERE WAS NO METHOD IN PLACE TO PREVENT PASSENGERS FROM USING THEIR BARE HANDS ON THE DOOR HANDLE TO EXIT THE TOILET ROOMS. THIS IS A NEW REQUIREMENT IN THE AUGUST 2005 VSP OPERATIONS MANUAL.
Recommendation: 9.1.1.1.3 Ensure that public toilet facilities are equipped so that persons exiting the toilet room are not required to handle the door with bare hands. This may be accomplished by methods such as locating paper towel dispensers at sinks and waste containers near the room door, installing mechanically operated doors, door removal, or other effective means.
Item No.: 08
Site: Potable Water-
Violation: THE HOSES ON THE BATH TUBS IN FOUR OF FIVE CABINS CHECKED DURING THE INSPECTION DID NOT HAVE A BACKFLOW PREVENTION DEVICE VISIBLE. THE AREA UNDER THE HOSE CONNECTIONS WERE NOT ACCESSIBLE DURING THE INSPECTION.
Recommendation: Ensure that all of the hoses that are long enough to enter below the flood level of the bathtub, sink, or shower have an appropriate, vented backflow prevention device installed.
Item No.: 33
Site: Provisions-FRESH VEGETABLE AND FRESH FRUIT WALK-IN REFRIGERATORS
Violation: FILTERS WERE MOUNTED ON BRACKETS FROM THE DECKHEAD, THE FILTERS APPEARED SOILED AND NO ONE SEEMED TO KNOW WHY THEY WERE INSTALLED.
Recommendation: Clean the mounted filters. If the filters are not needed, remove the filters.
Item No.: 33
Site: Provisions-ICE CREAM FREEZER
Violation: THERE WAS A LOOSE BULKHEAD/DECKHEAD PROFILE ON THE LEFT SIDE OF THE WALK-IN, MAKING THE AREA DIFFICULT TO CLEAN.
Recommendation: Reattach the loose profile.
Item No.: 20
Site: Preparation Room-
Violation: THE MEAT SAW WAS POSTED OUT OF ORDER AWAITING SPARE PARTS. THE MEAT SAW WAS LISTED AS OUT OF ORDER DURING THE LAST INSPECTION ON OCTOBER 29, 2004. DUE TO THE NEED TO REPOSITION THE UNIT, IT IS SCHEDULED FOR REPAIR DURING THE UPCOMING DRY DOCK IN DECEMBER 2005.
Recommendation: Repair, replace, or remove the meat saw.
Item No.: 08
Site: Potable Water-AUTOMATIC HOOD WASHING CABINETS
Violation: DUAL CHECK VALVE ASSEMBLIES WITHOUT INTERMEDIATE ATMOSPHERIC VENTS WERE INSTALLED ON THE HOOD WASHING SYSTEMS.
Recommendation: Replace the dual check valve assemblies with continuous pressure type backflow prevention devices which have intermediate atmospheric vents.
Item No.: 33
Site: Galley-HOT GALLEY
Violation: A LOOSE BULKHEAD PROFILE WAS NOTED ON THE LEFT SIDE OF THE COOK TOP, MAKING CLEANING DIFFICULT. THIS WAS A REPEAT ITEM FROM THE OCTOBER 29, 2004 INSPECTION.
Recommendation: Reattach the loose profile.
Item No.: 26
Site: Galley-GENERAL
Violation: SEVERAL SOILED, PREVIOUSLY CLEANED SHEET PANS WERE USED TO STORE FOOD CONTAINERS IN REACH-IN REFRIGERATORS.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Galley-POOL GRILL
Violation: THE HEATING COIL OF THE FRYER WAS BLACK WITH CARBONIZED COOKING OIL.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 20
Site: Galley-TERRACE CAFE
Violation: THE FRYER WAS LABELED OUT OF ORDER. IT WAS STATED THAT THIS UNIT HAD BEEN OUT OF ORDER FOR AT LEAST TWO MONTHS AWAITING SPARE PARTS.
Recommendation: Repair the fryer.
Item No.: 20
Site: Galley-HOT GALLEY
Violation: THE RIGHT SIDE FRYER WAS POSTED OUT OF ORDER. IT WAS STATED THAT THIS UNIT HAD BEEN OUT OF ORDER FOR AT LEAST TWO MONTHS AWAITING SPARE PARTS.
Recommendation: Repair the fryer.
Item No.: 38
Site: Galley-HOT GALLEY
Violation: THE VEGETABLE STEAMER WAS LABELED OUT OF ORDER. IT WAS STATED THAT THIS UNIT HAS NEVER BEEN USED.
Recommendation: Remove the vegetable steamer.
Item No.: 16
Site: Room Service-
Violation: A CONTAINER OF CREAM USED TO MAKE CAPPUCCINOS WAS FOUND IN AN ICE BATH WITH A PRODUCT TEMPERATURE OF 51°F. WHEN ASKED, IT WAS STATED THAT THIS PRODUCT WAS ON TEMPERATURE CONTROL. THERE WAS ALSO A CONTAINER OF MILK IN THE SAME ICE BATH WITH A PRODUCT TEMPERATURE OF 39°F. THE CREAM WAS DISCARDED DURING THE INSPECTION.
Recommendation: Maintain cold foods at temperatures 41°F or below or use time as the public health control for the dairy products.