Item No.:
20
|
|
Site:
Galley-PIZZA GRILL
|
|
Violation:
THE FLAT TOP GRILL LOCATED IN THE PIZZA GRILL WAS SEVERELY PITTED MAKING IT DIFFICULT TO CLEAN.
|
|
Recommendation:
Ensure that multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
20
|
|
Site:
Galley-PORTOFINO
|
|
Violation:
SLOTTED FASTENERS WERE NOTED IN THE FOOD CONTACT SURFACES OF THE FRYER, MAKING CLEANING DIFFICULT
|
|
Recommendation:
Replace with fasteners that are smooth, low profile and corrosion resistant.
|
|
|
Item No.:
36
|
|
Site:
Buffet-PORTOFINO BUFFET SERVICE SIDE
|
|
Violation:
INADEQUATE LIGHTING WAS NOTED ALONG THE WORKING AREA OF THE SERVICE SIDE OF THE BUFFET. THIS ITEM WAS NOTED DURING THE LAST INSPECTION.
|
|
Recommendation:
Ensure that the light intensity is at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
33
|
|
Site:
Buffet-PORTOFINO BUFFET SERVICE SIDE
|
|
Violation:
THE BULKHEAD/DECK JUNCTURE WAS NOT ADEQUATELY COVED, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-PORTABLE WATER TANK
|
|
Violation:
THE SAMPLE POINT FOR TANK FW4C WAS HORIZONTAL.
|
|
Recommendation:
Ensure that potable water tanks have sample valves which are turned down.
|
|
|
Item No.:
20
|
|
Site:
Galley-HOT LINE
|
|
Violation:
HOSE CLAMPS WERE USED TO HOLD THE THERMOSTAT IN PLACE IN THE FRYER. THE HOSE CLAMPS HAVE A ROUGH SURFACE AND A SLOTTED FASTENER, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Replace hose clamps with clamps that have a smooth surface and use fasteners that are smooth, low profile and corrosion resistant.
|
|
|
Item No.:
30
|
|
Site:
Galley-GLASSWASH AREA
|
|
Violation:
THERE WAS NO TRASH CAN AT THE HAND WASH STATION.
|
|
Recommendation:
Ensure that a handwashing facility includes a sink, soap dispenser, single-use towels dispenser, and waste receptacle.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-POTABLE WATER HOSES
|
|
Violation:
POTABLE WATER HOSES WERE NOT MARKED 'POTABLE WATER ONLY' AT EACH CONNECTING END. THIS IS A NEW REQUIREMENT IN THE AUGUST 2005 VSP OPERATIONS MANUAL.
|
|
Recommendation:
Ensure that all potable water hoses are labeled "potable water only" in letters at least 13 mm (1/2 inch) tall at each connecting end.
|
|
|
Item No.:
33
|
|
Site:
Food Service General-
|
|
Violation:
THERE WAS EXCESS GROUT ON THE DECK TILES UNDER EQUIPMENT THROUGHOUT THE FOOD SERVICE AREAS, MAKING CLEANING DIFFICULT. SPECIFIC AREAS INCLUDE: THE MAIN GALLEY COLD PANTRY, THE MAIN GALLEY DISHWASH, AND THE POOL BAR PANTRY. THE FLOORS HAD BEEN RECENTLY RE-GROUTED.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning. Remove the excess grout from the deck tiles in all food service areas.
|
|
|
Item No.:
21
|
|
Site:
Galley-HOT GALLEY
|
|
Violation:
PEELING SEALANT WAS NOTED IN THE VENTILATION HOOD ABOVE THE GRILLS.
|
|
Recommendation:
Remove the sealant in this area. Sealant is not required if seams are less than 0.8 mm (1/32 inch).
|
|
|
Item No.:
27
|
|
Site:
Galley-
|
|
Violation:
THE SURFACE ON THE OUTSIDE OF THE CUBER OF THE UPPER COMPARTMENT OF THE ICE MACHINE WAS SLIGHTLY SOILED WITH A BACK MATERIAL.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
33
|
|
Site:
Provisions-ROOM 1 FROZEN POULTRY
|
|
Violation:
AN ICE BUILD-UP WAS NOTED INSIDE AND AN ICICLE WAS HANGING OFF A LIGHT FIXTURE.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair. Repair the leak that is resulting in the collection of water (ice) in the light fixture.
|
|
|
Item No.:
38
|
|
Site:
Provisions-BUTCHER ROOM
|
|
Violation:
THE SIGN ON THE CLEANING LOCKER WAS UNREADABLE.
|
|
Recommendation:
Replace the sign on the designated cleaning locker.
|
|
|
Item No.:
33
|
|
Site:
Bar-GALILEO BAR
|
|
Violation:
THE DECK OF THE TECHNICAL SPACE BETWEEN THE UNDERCOUNTER REFRIGERATORS WAS HEAVILY SOILED WITH A WHITE SLIMY MATERIAL.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Bar-GALILEO AND POOL BAR
|
|
Violation:
THE GROUT WAS PULLING AWAY FROM THE BULKHEAD JUST INSIDE THE ENTRANCE DOORS TO THE PANTRY AREAS IN BOTH BARS. THIS GAP WAS DIFFICULT TO CLEAN.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
|
|
|
Item No.:
02
|
|
Site:
Medical-
|
|
Violation:
THERE WERE NO SHIPPING LABELS FOR CLINICAL SPECIMEN SUBMISSION. THIS IS A NEW REQUIREMENT IN THE AUGUST 2005 VSP OPERATIONS MANUAL.
|
|
Recommendation:
Ensure that shipping labels are available to submit clinical specimens.
|
|