Item No.:
02
|
|
Site:
Medical-Follow-up with Asymptomatic Cabin Mates
|
|
Violation:
The asymptomatic cabin mate of a crew member who reported with acute gastroenteritis (AGE) on 21 September was interviewed initially and then at 48 hours. The 24 hour interview was not conducted. The asymptomatic cabin mate of a crew member who reported with AGE on 22 September was interviewed initially and then at 48 hours. The 24 hour interview was not conducted. The asymptomatic cabin mate of a crew member who reported with AGE on 26 September was interviewed initially and at 24 hours. The 48 hour interview was not conducted.
|
|
Recommendation:
When any crew member (food or nonfood employee) meets the case definition for AGE, take the following actions: (1) restrict exposure to symptomatic crew member(s); (2) undergo a verbal interview with medical or supervisory staff, who will confirm their condition, provide facts and a written fact sheet about hygiene and handwashing, and instruct them to report immediately to medical if they develop illness symptoms; (3) complete a verbal interview daily with medical or supervisory staff until 48 hours after the ill crew members' symptoms began. Ensure that the first verbal interview is conducted within 8 hours from the time the ill crew member initially reported to the medical staff. If the asymptomatic immediate contact or cabin mate is at work, ensure that he or she must is contacted by medical or supervisory staff as soon as possible. Document the date and time of verbal interviews.
|
|
|
Item No.:
02
|
|
Site:
Medical-Follow-up with Asymptomatic Immediate Contacts
|
|
Violation:
It was not documented that the crew AGE cases reporting on 21 September, 22 September, and 26 September did not have immediate contacts other than cabin mates.
|
|
Recommendation:
Document whether crew AGE cases have immediate contacts other than cabin mates.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Hair and Lint Strainer and Housing Disinfection
|
|
Violation:
The concentration and contact time for the disinfection of all the hair and lint strainers and housings were not recorded for the disinfection completed on 15 September. The concentration and contact time for the disinfection of the cartridge filter housing on the spa pool was not recorded for the disinfection completed on 15 September.
|
|
Recommendation:
Clean, rinse, and disinfect the filter housing before the new filter media is placed in it. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures. Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
|
|
|
Item No.:
36
|
|
Site:
Pantry-Lighting
|
|
Violation:
The light intensity behind the ice machines in all deck pantries was less than 110 lux. This was written on the previous inspection. According to the staff, a light survey had been completed.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
33
|
|
Site:
Pantry-Deck 8 Forward and Midship
|
|
Violation:
The piping for the undercounter warewash machines in both pantries was on the deck. There were hooks located behind the machines for securing the piping above the deck.
|
|
Recommendation:
Remove the piping from the deck.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Spa Pool and Aquarius Pool
|
|
Violation:
The flotation devices at each pool did not have the ropes attached. At the Aquarius pool, the rope was also tied around the deck railing, making it difficult to remove quickly.
|
|
Recommendation:
Provide a rescue or shepherd's hook and an approved flotation device at a prominent location (visible from the full perimeter of the pool) at each RWF that has a depth of 1 meter (3 feet) or greater. Mount these devices in a manner that allows for easy access during an emergency. Ensure the pole of the rescue or shepherd's hook is long enough to reach the center of the deepest portion of the pool from the side plus 2 feet. Ensure it is a light, strong, nontelescoping material with rounded, nonsharp ends. Ensure the approved flotation device includes an attached rope that is at least 2/3 of the maximum pool width.
|
|
|
Item No.:
09
|
|
Site:
Recreational Water Facilities-Neptune Pool
|
|
Violation:
The chlorine levels in the swimming pool were measured at greater than 10 ppm twice and 9.89 ppm by the inspector. The pH was measured at 6.6 by the ship's staff and less than 6.5 by the inspector. According to the staff, they were aware that the chemistry was out of range and the pool was supposed to be closed. A net was previously on the pool, but upon arrival to the pool area by the inspection team, there was no net and passengers were on the pool deck. No one was in the pool. It was unclear why the net had been removed from the pool.
|
|
Recommendation:
Maintain a free residual halogen in recirculated RWFs in the following ranges: (1) swimming pools, between 1.0 and 5.0 mg/L (ppm); (2) children's pools, between1.0 and 5.0 mg/L (ppm); (3) wading pools, between 1.0 and 5.0 mg/L (ppm); (4) interactive RWFs (activity pools), between 2.0 and 5.0 mg/L (ppm); (5) baby-only water facilities, between 3.0 and 10.0 mg/L (ppm) free chlorine or between 4.0 and 10.0 mg/L (ppm) bromine; and (6) whirlpool spas and spa pools, between 3.0 and 10.0 mg/L (ppm) free chlorine or between 4.0 and 10.0 mg/L (ppm) bromine. Maintain the pH level in all RWFs between 7.0 and 7.8. Immediately close facilities if these halogen and pH ranges are not maintained.
|
|
|
Item No.:
09
|
|
Site:
Recreational Water Facilities-Aquarius Starboard Whirlpool
|
|
Violation:
The bromine levels in the whirlpool were measured at 3.62, 3.80, 3.65, and 4.07 ppm by the inspector. The ship's staff measured the bromine at less than 3 ppm. The chart recorder in the pump room was checked and it indicated that the levels were approximately 6 ppm during the testing period.
|
|
Recommendation:
Maintain a free residual halogen in recirculated RWFs in the following ranges: (1) swimming pools, between 1.0 and 5.0 mg/L (ppm); (2) children's pools, between1.0 and 5.0 mg/L (ppm); (3) wading pools, between 1.0 and 5.0 mg/L (ppm); (4) interactive RWFs (activity pools), between 2.0 and 5.0 mg/L (ppm); (5) baby-only water facilities, between 3.0 and 10.0 mg/L (ppm) free chlorine or between 4.0 and 10.0 mg/L (ppm) bromine; and (6) whirlpool spas and spa pools, between 3.0 and 10.0 mg/L (ppm) free chlorine or between 4.0 and 10.0 mg/L (ppm) bromine.
|
|
|
Item No.:
36
|
|
Site:
Galley-Lighting Behind Cooking Equipment - General Comment
|
|
Violation:
The light levels behind galley cooking equipment were measured at less than the required 110 lux. This was cited in the 01 FEB 2014 inspection in some of the same locations. Examples included: Deck 2 Main Galley, the light levels were 70 - 100 lux behind combination steamer ovens #JC/020706 and --707; Deck 3 Main Galley the light levels were 30 - 40 lux behind the three combination steamer ovens; and Deck 9 Belvedere Food Court galley behind all the combination steamer ovens the light levels were less than 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
33
|
|
Site:
Galley-Deck 2 - Hot Galley
|
|
Violation:
Large open holes were found in the bulkhead behind the tilting skillets where three new electrical cables had been installed to the tilting skillets. Additionally, water supply lines to these kettles had loose and missing flanges around the water lines.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
|
|
|
Item No.:
22
|
|
Site:
Galley-Deck 2 - Pot Wash
|
|
Violation:
A soap film was noted on the sanitizing water surface in the three-compartment sink.
|
|
Recommendation:
Ensure the wash, rinse, and sanitize solutions are maintained clean.
|
|
|
Item No.:
20
|
|
Site:
Galley-Deck 2 - Ocean Grill
|
|
Violation:
The black plastic hot water recirculating line in the pasta boiler had a black residue coming off the interior when it was touched. The interior of the pipe where the water traveled was rough and difficult to clean.
|
|
Recommendation:
Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition.
|
|
|
Item No.:
26
|
|
Site:
Galley-Deck 2 - Ocean Grill
|
|
Violation:
The black plastic hot water recirculating line in the pasta boiler was soiled with dried pasta pieces. The unit had been previously cleaned and stored.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
20
|
|
Site:
Galley-Deck 2 - Pot Wash
|
|
Violation:
A large yellow plastic cutting board was heavily scored by sharp knives and made difficult to clean.
|
|
Recommendation:
Ensure surfaces such as cutting blocks and boards that are subject to scratching and scoring are resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
|
|
|
Item No.:
26
|
|
Site:
Galley-Deck 2 - Ocean Grill
|
|
Violation:
A knife stored on the preparation table in a clean item storage pan had a small amount of food grease on the blade. The entire pan of utensils was sent for rewashing.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
22
|
|
Site:
Galley-Deck 2 - Dishwashing
|
|
Violation:
The flight-type dishwasher had an analog gauge that was not accurate. The gauge read the final rinse water manifold temperature at 207°F. A direct water temperature was taken inside the manifold through the spray nozzle with the inspector's calibrated thermocouple. This direct measurement was 198°F, or 9 °F lower. The allowable difference is +/- 3°F.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
16
|
|
Site:
Galley-Deck 3 - Cold Pantry
|
|
Violation:
Two rounds of cut blue cheese were in a pan in the undercounter reach-in cooler without a seven-day expiration date label. Two other rounds of this cheese were in a different pan with a 01 OCT 2014 discard date.
|
|
Recommendation:
Ensure refrigerated, ready-to-eat, potentially hazardous food: (2) Prepared and packaged by a food-processing plant and held on the vessel after opening for more than 24 hours must be clearly marked at the time the original container is opened to indicate the date by which the food must be consumed (7 calendar days or fewer after the original container is opened). The day of opening is counted as day 1.
|
|
|
Item No.:
20
|
|
Site:
Preparation Room-Deck A - Production
|
|
Violation:
The dough molder belt was frayed along the left side facing the machine which made it difficult to clean. The right side had some holes that also contributed to effective cleaning problems.
|
|
Recommendation:
Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition.
|
|
|
Item No.:
26
|
|
Site:
Preparation Room-Deck A - Production
|
|
Violation:
The right side of the dough molder belt was filled with dried old dough after the unit had been stored as clean. Additionally, the interior of the roller unit had dried dough residue in it after the unit had been stored as clean.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Preparation Room-Deck B - Production
|
|
Violation:
Old potato residue was noted in the door gasket groove and on the door gasket. The potato peeler had been previously cleaned.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Deck B - Frozen Meat Storage
|
|
Violation:
Water had leaked from the deckhead through a light fixture in the back right area of the meat freezer. The frozen leak was captured in a cardboard box lined with a plastic bag. No food was impacted.
|
|
Recommendation:
Repair the leak.
|
|