|
|
|
Item No.:
*
|
|
Site:
Medical-Food handlers working while experiencing Gastrointestial Illness (GI)
|
|
Violation:
During the 7/27-8/8 voyage, a food handler worked while experiencing GI symptoms. During the 7/13-7/27 voyage, a food handler worked while experiencing GI symptoms. During the 7/6-7/13 voyage, a food handler worked while experiencing GI symptoms. These voyages occurred while the vessel was sailing outside of the U.S. All crew members were reprimanded for reporting late to medical, and working while experiencing GI.
|
|
Recommendation:
Ensure food employees who have conditions or symptoms of boils, open sores, infected wounds, diarrhea, jaundice, fever, vomiting, sore throat with fever, or discharges from the nose or mouth report these conditions or symptoms to the vessel's medical staff and are restricted from working with exposed food, warewashing, clean equipment, utensils, and linens, and unwrapped single-service and single-use articles.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Tank Sample Cock
|
|
Violation:
Hose bib vacuum breakers were listed on the cross connection control log for the potable water tank sample cocks. A hose bib vacuum breaker was absent for the sample cock of potable water tank 1 port. This was immediately corrected.
|
|
Recommendation:
Ensure the cross-connection log reflects the backflow prevention devices installed on the vessel. Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Tank Maintenance Records
|
|
Violation:
The third party certification for the tank coating used in the potable water tanks was not provided. The vessel had a certification letter which referred to a different coating than the tank coating used for the tanks.
|
|
Recommendation:
Ensure the interior coatings on potable water tanks are approved for potable water contact by a certification organization. Follow all manufacturers? recommendations for application, drying, and curing. For the tank coatings used, maintain the following onboard: (1) written documentation of approval from the certification organization (independent of the coating manufacturer).
|
|
|
Item No.:
33
|
|
Site:
Buffet-Colonnade Waiter Station #2
|
|
Violation:
The station/deck juncture was not coved on the right side of the waiter station. Carafes of coffee were stored on the top shelf of the waiter station, making this a working side. In addition, some of the coving on the front of the station was missing. A work order was created for both repairs.
|
|
Recommendation:
Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel). Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
28
|
|
Site:
Galley-Dishwash Area
|
|
Violation:
A rack of clean glasses was stored directly adjacent to the soiled landing table with soiled items. The rack was immediately moved.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (2) in a location where they are not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
21
|
|
Site:
Galley-Coffee Station
|
|
Violation:
The glass on the coffee machine milk refrigerator was cracked on the coffee machine adjacent to the upright refrigerator. A work order had already been submitted.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
21
|
|
Site:
Galley-Show Galley
|
|
Violation:
The panel on the underside of the grill was missing a fastener and the panel was partially loose. In addition, loose and peeling sealant was observed. A work order was immediately submitted.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Galley-Show Galley
|
|
Violation:
The underside of the grill was soiled with grease.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
21
|
|
Site:
Other-Patio Grill
|
|
Violation:
The metal parts of the two front wheels on the pizza oven were heavily corroded. A work order for replacement parts had already been submitted.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
21
|
|
Site:
Dining Room-Waiter Stations
|
|
Violation:
Holes were observed in the bottoms of the two top shelves on all of the side storage shelves of the waiter stations. These holes were present due to a metal bracket piece being removed. Food items, such as salt and pepper shakers and sugar packets, were stored on several of these shelves.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
22
|
|
Site:
Galley-Potwash Area
|
|
Violation:
An excessive amount of soiled items were stored outside of and leading into the potwash area. Several trolleys had soiled items stored outside the potwash, making it difficult to walk through the corridor and into the potwash area.
|
|
Recommendation:
Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing.
|
|
|
Item No.:
19
|
|
Site:
Galley-Potwash Area
|
|
Violation:
Possible food contamination was noted from the excessive amount of soiled items were stored outside of and leading into the potwash area, as described in Item 11. The trolleys with soiled items were less than one meter from clean preparation counters and others were approximately 300 mm from an open kettle of cooking stock.
|
|
Recommendation:
Protect food from contamination by storing the food: (3) Where it is not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
28
|
|
Site:
Galley-Potwash Area
|
|
Violation:
Possible clean food equipment contamination was noted from the excessive amount of soiled items were stored outside of and leading into the potwash area, as described in Item 11. Several trolleys had soiled items stored less than one meter from clean storage of waiter trays.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (2) in a location where they are not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
19
|
|
Site:
Galley-
|
|
Violation:
The top tray of hamburgers on a trolley was uncovered. The trolley was staged by the grill for cooking.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected.
|
|
|
Item No.:
14
|
|
Site:
Preparation Room-
|
|
Violation:
A crew member with a goatee was not wearing a beard restraint. He was observed cleaning the orange juice machine. According to the crew member, he wore a beard restraint when chopping vegetables.
|
|
Recommendation:
Ensure food employees wear hair restraints and clothing that covers body hair. Ensure these items are designed and worn effectively to prevent hair from contacting exposed food; clean equipment, utensils, and linens; and unwrapped single-service and single-use articles.
|
|
|
Item No.:
36
|
|
Site:
Bar-Seabourn Square
|
|
Violation:
The light intensity at the handwashing station was less than 110 lux during operations.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at handwashing stations in bars.
|
|
|
Item No.:
20
|
|
Site:
Bar-Seabourn Square
|
|
Violation:
On the espresso machine, the area above the coffee making heads and steam wands was open exposing difficult to clean features. There was no splash panel installed.
|
|
Recommendation:
Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (3) finished to have a smooth, easily cleanable surface.
|
|
|
Item No.:
16
|
|
Site:
Bar-Seabourn Square
|
|
Violation:
The time control plan did not indicate the ice well on the front bar counter as an area on time control. Containers of milk were on time control in the ice well during the inspection.
|
|
Recommendation:
Include the ice well on the time control plan.
|
|
|
Item No.:
33
|
|
Site:
Bar-Patio - Outside Waiter Station
|
|
Violation:
The deckhead above this area was made of a soft canvas material with grommets and rope. Dust was observed in a few areas on the rope. Clean glasses and cans of soda were stored directly below the canvas and dusty rope. A work order was submitted to replace the deckhead material with a hard, durable, and easily cleanable material.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
19
|
|
Site:
Pantry-Pantry #7
|
|
Violation:
Several unopened bottles of water and soda were stored on a table directly adjacent to the soiled storage racks. According to the staff, these bottles were from the cabins and would be sanitized and sent back to provisions for storage.
|
|
Recommendation:
Protect food from contamination by storing the food: (3) Where it is not exposed to splash, dust, or other contamination.
|
|