Item No.:
40
|
|
Site:
Integrated Pest Management-IPM - Training
|
|
Violation:
The staff responsible for conducting the routine inspections for pest management and placing traps and baits around the ship was trained by the person they relieved in that position, but there was no documentation of the training.
|
|
Recommendation:
Document the training of the pest-control personnel.
|
|
|
Item No.:
26
|
|
Site:
Galley-Main Galley - Cold Galley
|
|
Violation:
The large can opener set in the holder at the central preparation counter in the cold galley was heavily soiled on the blade and all surfaces surrounding the blade and guard with a heavy build-up of food debris and metal filings. The sleeve-type holder the can opener slides into for storage was also heavily soiled with old food debris.
|
|
Recommendation:
Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
16
|
|
Site:
Galley-Main Galley - Cold Galley
|
|
Violation:
Two opened packages containing sliced deli turkey meat were found inside the 3 door upright reach-in refrigerator without discard labels affixed.
|
|
Recommendation:
Ensure refrigerated, ready-to-eat, potentially hazardous food: (2) Prepared and packaged by a food-processing plant and held on the vessel after opening for more than 24 hours must be clearly marked at the time the original container is opened to indicate the date by which the food must be consumed (7 calendar days or fewer after the original container is opened). The day of opening is counted as day 1.
|
|
|
Item No.:
28
|
|
Site:
Galley-Main Galley - Cold Galley
|
|
Violation:
Two large ice buckets were stored inverted and stacked on a soiled counter beside the ice machine. The opening of the lower ice bucket was in contact with that counter.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck. Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
|
|
|
Item No.:
21
|
|
Site:
Galley-Main Galley - Cold Galley
|
|
Violation:
The small, bulkhead-mounted microwave oven was set on a bulkhead mounted shelf with a distance of less than 1/2 inch above the shelf, making cleaning below very difficult.
|
|
Recommendation:
Ensure table-mounted equipment that is not easily movable is elevated on legs that provide at least a 100 mm (4-inch) clearance between the table and the equipment.
|
|
|
Item No.:
27
|
|
Site:
Galley-Main Galley - Cold Galley
|
|
Violation:
The shelf below the microwave oven was soiled with accumulated food debris and small metal parts.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
36
|
|
Site:
Galley-Main Galley - Cold Galley
|
|
Violation:
The artificial light level beside and around the ice machine was below the minimum 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
20
|
|
Site:
Galley-Main Galley - Beverage Counter
|
|
Violation:
There were six slot-head screws fastened into the underside splash panel of each of the six soft drink dispensing heads at the beverage counter, making this splash zone difficult to clean.
|
|
Recommendation:
Contact the equipment repair technician for a solution to this issue, as they can either swap out the dispensing head or provide a shielding for the slotted screws.
|
|
|
Item No.:
26
|
|
Site:
Galley-Main Galley - Beverage Counter
|
|
Violation:
There was a significant splash of old beverage residue on the underside of all six of the soft drink dispensers, surrounding each dispensing head.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch. Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
36
|
|
Site:
Galley-Main Galley - Beverage Counter
|
|
Violation:
The artificial light level at the beverage dispensing counter was below the minimum 220 lux required.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
27
|
|
Site:
Galley-Main Galley - Dishwash
|
|
Violation:
There was a heavy layer of dried food debris on the top exterior surface of the hood type dishwash machine.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
22
|
|
Site:
Galley-Main Galley - Dishwash
|
|
Violation:
Two dishware racks were stored on edge on the dirty deck. There were deck stands available for storage of these dishware racks.
|
|
Recommendation:
Ensure the staff use the available deck stands for storing dishware racks between uses. Never store dish racks on the deck.
|
|
|
Item No.:
33
|
|
Site:
Galley-Main Galley - General
|
|
Violation:
Deckhead and bulkhead mounted equipment such as cables, piping, and bells were installed too close to the bulkheads and deckheads for easy cleaning. Several of these attached pieces were heavily soiled with dust or dirt debris. A hot galley deckhead mounted air supply vent near the range tops was soiled with a layer of grease residue.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Galley-Main Galley - Hot Galley
|
|
Violation:
The canopy exhaust hood over the two range units had a heavy old grease layer in all the hood filters.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
16
|
|
Site:
Galley-Main Galley - Pastry
|
|
Violation:
There were two opened large blocks of butter with no 7 day discard date affixed found inside the three door reach-in refrigerator.
|
|
Recommendation:
Ensure refrigerated, ready-to-eat, potentially hazardous food: (2) Prepared and packaged by a food-processing plant and held on the vessel after opening for more than 24 hours must be clearly marked at the time the original container is opened to indicate the date by which the food must be consumed (7 calendar days or fewer after the original container is opened). The day of opening is counted as day 1.
|
|
|
Item No.:
33
|
|
Site:
Galley-Main Galley - Pastry
|
|
Violation:
The pastry clean dish rack was set below an existing canopy exhaust hood, The filters installed in the hood were heavily soiled with a layer of dust debris. These soiled filters exposed the clean dishware stored below to contamination.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
28
|
|
Site:
Galley-Main Galley - Pastry
|
|
Violation:
The pastry clean dish rack was set below an existing canopy exhaust hood, The filters installed in the hood were heavily soiled with a layer of dust debris. These soiled filters exposed the clean dishware stored below to contamination.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Dry Storage Area
|
|
Violation:
There were difficult to clean cable bundles attached to both deckheads and bulkheads in this food storage area. As well there were overhead pipes of wastewater and fire piping. The decks throughout the room were pitted, making cleaning difficult.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
36
|
|
Site:
Dining Room-Wine Counter
|
|
Violation:
The artificial light level at the wine counter was below the minimum 220 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at handwashing stations in bars. In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
|
|
|
Item No.:
33
|
|
Site:
Dining Room-Wine Counter
|
|
Violation:
The deck was carpeted at the wine counter. This counter is used to fill empty wine bottles from several dispenser taps connected to an undercounter refrigerator with various wine in kegs.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
|
|
|
Item No.:
33
|
|
Site:
Bar-Lounge Bar
|
|
Violation:
The deckhead was a decorative acoustic ceiling tile design, which was rouch, absorbent, non-durable and difficult-to-clean material. There was damage at the deck surface in places, and there were holes in the lower, forward/starboard corner of the bulkhead, beside the handwash sink. Staff stated the entire bar counter was to be re-constructed in the fall.
|
|
Recommendation:
Ensure bulkheads and deckheads have smooth, hard finishes and light colored surfaces. Exception: bars may have decorative surfaces provided that they are easily cleanable. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
19
|
|
Site:
Bar-Lounge Bar
|
|
Violation:
It was not clear that either the ice bin drain or the drain from the small undercounter glasswashing machine actually drained indirectly to waste. An air-break was not visible below either.
|
|
Recommendation:
Ensure drain lines from all fixtures, sinks, appliances, compartments, refrigeration units, or devices that are used, designed for, or intended to be used in the preparation, processing, storage, or handling of food, ice or drinks are indirectly connected to appropriate waste systems by means of an air gap or air break.
|
|
|
Item No.:
05
|
|
Site:
Potable Water-Distribution System - Far Point
|
|
Violation:
A manual comparison test was made to verify the chlorine residual at the far point chlorine analyzer. The analyzer reading was 0.65 ppm free chlorine while the inspector's kit registered 1.55 ppm. On the second test the analyzer reading was 0.61 ppm while the inspector's kit registered 1.41 ppm.
|
|
Recommendation:
Ensure the free residual halogen measured by the halogen analyzer is within 0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Whirlpool Spas
|
|
Violation:
An automated pH and halogen dosing and control system was not installed on this ship. Staff batch feed chemicals to control pH and chlorine. This was noted in the July, 2014 VSP inspection as well. Staff stated the installation of automated dosing and control equipment is part of the fall 2014 dry dock maintenance.
|
|
Recommendation:
Before arriving in a port or harbor, drain the RWF before the vessel reaches the 20 kilometers (12 mile) mark or any point of land-based discharge as outlined in section 6.1.1.1.1, and ensure the RWF remains empty while in port or at anchor. Or, shut off the RWF seawater filling system 20 kilometers (12 miles) before reaching the nearest land or land-based discharge point, and use a recirculation system with appropriate filtration and halogenation.
|
|