Cruise Ship: Pearl Mist Cruise Line: V. Ships Leisure U.S.A. Inspection Date: 09/10/2014 Inspection Score: 74
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: *
Site: Dining Room-Crew Mess
Violation: Verify all artificial light levels across the full counter for beverages as well as the the buffet counter to ensure a minimum 220 lux.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 03
Site: Potable Water-Production
Violation: The ship's two reverse osmosis production plants must be used to produce water for potable consumption on two days per month, which are sea days. There is no connection between the reverse osmosis production and the newly installed bunker chlorination equipment, so the water produced into the potable water tanks twice monthly is not chlorinated until it leaves the tanks and the post chlorination equipment doses that water. Staff stated the piping connection between RO plants and the potabe water chlorination system will be made in the October, 2014 dry dock.
Recommendation: Continuously halogenate potable water to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device that is controlled by a flow meter and adjust the pH so it does not exceed 7.8. Ensure the amount of halogen injected during bunkering or production is controlled by a flow meter or a free halogen analyzer.
Item No.: 08
Site: Potable Water-Cross-Connection Control
Violation: Several non-vented backflow prevention devices were observed (007 models) for the reverse osmosis system. Additionally, the listing of cross-connections was incomplete (missing toilets, clothes washers, ice machines and galley chemical locker) and did not include non-testable devices.
Recommendation:
Item No.: 12
Site: Galley-Main Galley - Dishwash
Violation: One of the staff operating the conveyor dishwash machine placed their personal container of a red sports drink on top of the machine during use for consumption while working.
Recommendation: Ensure employees eat, drink, or use any form of tobacco only in designated areas where the contamination of exposed food; clean equipment, utensils, and table linens; unwrapped single-service and single-use articles; or other items needing protection cannot occur.
Item No.: 15
Site: Provisions-Walk-in Freezer
Violation: Boxes of raw oysters in shell were found inside the walk-in freezer. Staff serve these cooked in two separate menu items, but there was no system on board for maintaining the tags for at least 90 days after the box was emptied and no information on when the oysters were served.
Recommendation: Ensure shellstock shellfish tags: (1) Remain attached to the container in which the shellstock are received until the container is empty. (2) Are maintained by retaining shellstock tags or labels for 90 calendar days from the date the container is emptied by using an approved record-keeping system that keeps the tags or labels in chronologic order correlated to the date when the shellstock are served and the date when the last shellstock from the container is served is recorded on the tag or label.
Item No.: 16
Site: Galley-Main Galley - Hot Galley
Violation: A sauce pan containing oil and a half block of butter was set on a small counter beside the range and grill area. Staff said it was to be melted for the lunch service at 11:30. The time of inspection was 10 am and there was no time discard label on the pan which was said to be on time control. The butter had an internal temperature of 54-55 °F, and no correction was made during the hour the inspector was evaluating the galley.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 16
Site: Galley-Main Galley - Hot Galley
Violation: Inside the two door reach-in refrigerator #4 was a pan of cooked link sausage with a label noting preparation on 9 September and discard on 15 September. The sausage had an internal temperature of 92 °F and staff stated that it was taken from the bain marie at the end of breakfast service (9 am) and placed in the refrigerator. The posted time control plan indicated hot foods on the bain marie would be discarded after service. Another hotel pan in the same refrigerator contained cooked bacon with a temperature of 62 °F. This too was on the bain marie and not discarded per the time control plan. Both pans of food were discarded in full view of the inspector.
Recommendation: If time only?rather than time in conjunction with temperature?is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control. (2) Is not be placed on temperature control again. (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours. and (4) Is discarded within 4 hours of placement on time control.
Item No.: 16
Site: Galley-Main Galley - Hot Galley
Violation: A pan of baked beans and a pan of cooked link sausages were found inside reach-in refrigerator #4 without the required 7 day discard labels affixed. In addition, staff made no entry in the cooling logs for either of these foods. Staff stated the beans were from a tin. Additionally, there was a large pan of pasteurized egg liquid and four sheet pans with individual bowls of raw eggs, which staff stated were individually cracked to load the pans just 2 hours prior. The eggs had temperatures of 53 °F and no entry was made in the cooling logs for these items. Both the pasteurized egg in the large pan and all the shelled eggs in bowls were immediately removed and blast chilled.
Recommendation: Ensure refrigerated, ready-to-eat, potentially hazardous food: (2) Prepared and packaged by a food-processing plant and held on the vessel after opening for more than 24 hours must be clearly marked at the time the original container is opened to indicate the date by which the food must be consumed (7 calendar days or fewer after the original container is opened). The day of opening is counted as day 1. Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 16
Site: Galley-Main Galley
Violation: Inside the walk-in refrigerator were two bags of leafy greens in a spring mix which had food temperatures between 45 and 47 °F.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 17
Site: Galley-Main Galley
Violation: Inside reach-in refrigerator #8 was a small hotel pan of sliced salami meat along with the partial loaf of meat. The same meat particles were noted on the counter slicer. The internal temperature of the meat in the refrigerator was 61 °F and there was no entry in the cooling log for this meat.
Recommendation: Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days form the date the food was placed in the cooling process. Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 17
Site: Galley-Main Galley - Hot Galley
Violation: A pan of baked beans and a pan of cooked link sausages were found inside reach-in refrigerator #4 without the required 7 day discard labels affixed. In addition, staff made no entry in the cooling logs for either of these foods. Staff stated the beans were from a tin. Additionally, there was a large pan of pasteurized egg liquid and four sheet pans with individual bowls of raw eggs, which staff stated were individually cracked to load the pans just 2 hours prior. The eggs had temperatures of 53 °F and no entry was made in the cooling logs for these items. Both the pasteurized egg in the large pan and all the shelled eggs in bowls were immediately removed and blast chilled.
Recommendation: Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days form the date the food was placed in the cooling process. Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 17
Site: Galley-Main Galley and Provisions
Violation: Cold smoked salmon appetizers were found in a galley reach-in refrigerator as well as many fillets found in the provisions walk-in refrigerators. There was no documentation that any of these were frozen either by the supplier or ship to a temperature or time sufficient to destroy parasites and their eggs.
Recommendation: If raw, raw-marinated, partially cooked, or marinated partially cooked fish are served in ready-to-eat form, ensure: (1) The person in charge records the freezing temperature and time to which the fish are subjected and retains the records on the vessel for 90 calendar days beyond the time of service or sale of the fish; or (2) If the fish are frozen by a supplier, a written letter from the supplier which specifies the fish species involved and both the temperature to which the fish was frozen and the total time period at that temperature. If the supplier provides any of the same species to the vessel in a fresh state, ensure there is a designation on the outer packaging for the parasite-free fish.
Item No.: 19
Site: Food Service General-Dining Room - Waiter Stations
Violation: Although some deck stands have been put in place since the previous inspection, there were still many packaged foods set directly on the deck and stacked in most of the cold rooms, dry storage room, and the provisions corridor. As there are no mounted food racks in the walk-in cold rooms there was a tendency for the stacked boxes of food to tilt and fall over due to the ship's movement, so some rooms such as the meat walk-in had several boxes tumbled onto the deck on top of one another.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 19
Site: Dining Room-Crew mess
Violation: The hot service counter was a table set on a carpet with 5 portable bain maries set beside each other, with no cover or sneeze shield installed for crew self-service. During inspection a completely new counter was delivered with a full bain marie cabinet with attached sneeze shields.
Recommendation: Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
Item No.: 21
Site: Galley-Main Galley - Hot Galley
Violation: There were difficult to clean crevices and gaps present along the top and sides of the interior of the chute for the flat-top grill and grooved griddle grease pan housings.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Dining Room-Crew Mess
Violation: The upright reach-in refrigerator was set on legs less than the minimum 150 mm height above the deck.
Recommendation: Ensure deck-mounted equipment that is not easily movable is sealed to the deck or elevated on legs that provide at least a 150 mm (6-inch) clearance between the deck and the equipment.
Item No.: 21
Site: Dining Room-Dining Room - Waiter Stations
Violation: The distance from the deck to the bottom cabinet of all the dark brown waiter stations was 100 mm. These were located in the middle and forward sections of the dining room, as well as in the pantry between dining room and galley.
Recommendation: Ensure deck-mounted equipment that is not easily movable is sealed to the deck or elevated on legs that provide at least a 150 mm (6-inch) clearance between the deck and the equipment.
Item No.: 21
Site: Bar-Atlantic Lounge Bar
Violation: The handwash sink and paper towel dispensers were not equipped with shields to prevent water splash onto the drink preparation counter during handwashing and drying of hands.
Recommendation: Install shielding if the paper towel dispensers cannot be moved away to protect the drink preparation counter from soiled splash.
Item No.: 21
Site: Other-Atlantic and Pacific Lounge
Violation: The small undercounter ice machine in the Atlantic Lounge was mounted on legs less than the minimum 150 mm height.
Recommendation: Ensure deck-mounted equipment that is not easily movable is sealed to the deck or elevated on legs that provide at least a 150 mm (6-inch) clearance between the deck and the equipment.
Item No.: 21
Site: Galley-Main Galley - Coffee Counter
Violation: The coffee machine was mounted on legs less than 100mm above the counter.
Recommendation: Ensure table-mounted equipment that is not easily movable is elevated on legs that provide at least a 100 mm (4-inch) clearance between the table and the equipment.
Item No.: 21
Site: Dining Room-Dining Room - Waiter Stations
Violation: The lighter brown color cabinets for the aft waiter station had an absorbent bare wood set of trim pieces on the interior back upper panel of each, and a similar bare wood trim piece inside near the hinges. Additionall, there was a difficult to clean gap present along the top interior side panel where two cabinet sections joined. A dark brown waiter station cabinet was installed in the middle and forward sections of the dining room, and all these had bare wood draweres whcih were absorbent as well. This was noted in the previous VSP inspection.
Recommendation: Use only hard, non-absorbent materials for construction of cabinets, including trim pieces. Profile gaps and seal seams in furnishings.
Item No.: 21
Site: Other-Atlantic Lounge
Violation: The newly installed counter model coffee/cappuccino machines in the lounge snack and beverage counter were not installed on legs at least 100mm above the counter and were not sealed to the counter top.
Recommendation: Ensure table-mounted equipment that is not easily movable is elevated on legs that provide at least a 100 mm (4-inch) clearance between the table and the equipment.
Item No.: 22
Site: Galley-Main Galley - Dishwash
Violation: During active warewashing the final sanitizing rinse upper spray arm was detached and wedged in an upright position beside the conveyor support. The inspector pointed it out and where it was to be fastened during the inspection.
Recommendation: Ensure the galley staff involved with operations and evaluations of the dishwashers understand and routinely inspect the components inside the machines and repair and replace those parts throughout before the operations starts and regularly during use.
Item No.: 23
Site: Galley-Main Galley - Dishwash
Violation: During active use of the conveyor dishwash machine the water in the wash tank measured only 150 °F, but the manufacturer's data plate required a minimum 160 °F in the wash tank.
Recommendation: Ensure the temperature of the wash solution in spray type warewashers that use hot water to sanitize is not less than: (1) 74°C (165°F) for a stationary-rack, single-temperature machine; (2) 66°C (150°F) for a stationary-rack, dual-temperature machine; (3) 71°C (160°F) for a single-tank, conveyor, dual-temperature machine; (4) 66°C (150°F) for a multi-tank, conveyor, multi-temperature machine.
Item No.: 28
Site: Galley-Main Galley - Dishwash
Violation: There were some deck stands in use for dishware racks, but still staff were observed setting dishware racks from the in-use conveyor machine on the wet deck between uses. On the soiled staging side of the operation there was a stack of several dishware racks directly on the deck, and another stack of dishware racks with two used microwave ovens stacked on top at the soiled area.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
Item No.: 29
Site: Bar-Atlantic Lounge Bar
Violation: There was only a counter mounted handwash sink at the front bar counter. Based on the liquors stored undercounter and mixing confirmed by the staff, there is a need for a utility sink at this bar to prevent staff using the handwash sink basin for mixing operations. During the inspection there was only pouring of Champagne observed.
Recommendation: Ensure handwashing facilities are used for no other purpose and are accessible at all times. Install a utility sink for the mixed drink preparation and dumping.
Item No.: 33
Site: Dining Room-Crew mess
Violation: Both the coffee/cold beverage table and the buffet/bain marie table in this mess room were installed on a carpet covered deck.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
Item No.: 33
Site: Dining Room-Dining Room - Waiter Stations
Violation: The three forward waiter station were all installed on carpeting.
Recommendation:
Item No.: 33
Site: Other-Atlantic and Pacific Lounge
Violation: The self-service canape tables in the lounge section were installed on carpeting.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
Item No.: 34
Site: Galley-Entry Handwash
Violation: The single handwash sink basin at the dining room entry to the galley had pooled wastewater on the deck surrounding, because the drain pipe to the deck sink was not aligned properly.
Recommendation: Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
Item No.: 36
Site: Dining Room-Dining Room - Waiter Stations
Violation: There was no artificial light installed at the forward waiter statio and the level was below the minimum 220 lux during service. In the aft/port and starboard waiter stations there was a single light fixture installed over one end of the waiter station, but the bulb for each was not fully shielded and was not verified to be shatter-resistant. Light levels for all three forward stations and the single mid dining room station should be verified by a light meter.
Recommendation:
Item No.: 36
Site: Galley-Main Galley - Coffee Counter
Violation: The artificial light level was below 110 lux behind and around the coffee machine.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 36
Site: Galley-Main Galley - Ice Machine
Violation: The artificial light level behind and around the large ice machine was below the minimum 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 36
Site: Dining Room-Crew Mess
Violation: The artificial light level behind and around the upright reach-in refrigerator was below the minimum 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 36
Site: Other-Atlantic and Pacific Lounge
Violation: the artificial light level was below the minimum 220 lux at both snack and drink counters. The partly shielded bulkhead-mounted lights over the snack and drink counters did not have a shatter-resistant bulb installed.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 36
Site: Other-Atlantic Lounge
Violation: There was no artificial light for the undercounter ice machine at the Atlantic Lounge Bar.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 39
Site: Galley-Main Galley
Violation: One live filth fly was observed in the galley during active food preparation. The fly was landing on food counters.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 40
Site: Integrated Pest Management-IPM Plan and Implementation
Violation: There has been training of staff and supplies for implementation of pest management received on board. The logs for different plan elements were written with frequencies of the work, but none filled in as yet. The overall plan was not yet written and baits or traps have yet to be placed around the ship.
Recommendation:
Item No.: 41
Site: Housekeeping-Public Toilets
Violation: Although there are now signs on toilet room doors indicating use of paper towel to handle the door upon exit, there was no sign or pictogram at the handwash sink indicating to wash hands.
Recommendation: Provide the passenger and crew public toilets with a handwashing station that includes: (1) Hot and cold running water; (2) Soap; (3) A method to dry hands; (4) A sign advising users to wash hands.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan
Violation: Although in progress, the written OPRP was still not corrected from the previous VSP inspection. Contact times were needed for disinfectants. Continuous cleaning and disinfection statements were needed at illness levels of 2% and higher, and procedures for passenger notifications of an outbreak were not detailed.
Recommendation: Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (1) Duties and responsibilities of each department and their staff for all the passenger and crew public areas; (2) Steps in outbreak management and control and the trigger for required action at each step. Ensure the triggers address a graduated approach to outbreak management in response to increasing case counts; (3) Disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times. Ensure the disinfectant products or systems are effective against human norovirus or an acceptable surrogate (e.g., caliciviruses); (4) Procedures for informing passengers and crew members of the outbreak. Ensure this section also includes procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage; (5) Procedures for returning the vessel to normal operating conditions after an outbreak; (6) Procedures to protect the passengers and crew from exposure to disinfectants, if not already included in the vessel?s safety management system. Ensure this protection includes: (a) Material safety data sheets (MSDSs); (b) Personal protective equipment for crew; (c) Health and safety procedures to minimize respiratory and dermal exposures to both passengers and crew.
Item No.: 44
Site: Potable Water-Microbiological Tests of Water
Violation: Medical staff conduct the microbiological tests of the port water and ship's distribution potable water system. In the records the potable water bunker test indicates, and staff confirmed, that the test is made from the end of the ship's hose, rather than direct from the port supply tap.
Recommendation: Ensure the supervisor or person in charge of potable water operations on the vessel demonstrates to VSP?during inspections and on request-knowledge of potable water operations, is able to demonstrate this knowledge by compliance with Section 5 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 5 of the VSP 2011 Operations Manual as it relates to their assigned duties. Ensure staff collect port water samples from the port tap and prior to connecting the ship's bunkering hose to that tap.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program