Item No.:
06
|
|
Site:
Potable Water-Far Point Analyzer
|
|
Violation:
The far point analyzer chart recorder worked in the opposite direction as the times written on the charts. The times went counter-clockwise, whereas the pen documented chlorine values in a clock-wise rotation. During the inspection of the area at 11:30, the analyzer chart read 13:30.
|
|
Recommendation:
Construct and install halogen and pH analyzer-chart recorders used on bunker water systems according to the manufacturer?s guidelines.
|
|
|
Item No.:
20
|
|
Site:
Galley-Deck 2- Galley Clean Cutting Board Storage
|
|
Violation:
More than 4 cutting boards were identified with deep crevices and discolorations that made cleaning difficult. Some plastic fibers were noted that could easily be transferred to food.
|
|
Recommendation:
Ensure surfaces such as cutting boards that are subject to scratching and scoring are resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
|
|
|
Item No.:
26
|
|
Site:
Galley-Deck 2 - Galley Clean Glaseware and Storage
|
|
Violation:
More than 3 wine glasses were identified with lip marks on the rim.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
36
|
|
Site:
Galley-Deck 6- Pantry Adjacent to Kitchen
|
|
Violation:
Two light bulbs were missing or burned out in this area resulting in a measured light intensity of 180 lux, This was corrected.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in utensil storage, and pantry areas.
|
|
|
Item No.:
36
|
|
Site:
Bar-Deck 6 - Night Bar
|
|
Violation:
Lighting in this area was measured at an intensity of 96 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at handwashing stations in bars. In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
|
|
|
Item No.:
36
|
|
Site:
Galley-Deck 6 - Lighting Behind Ice Maker
|
|
Violation:
Lighting behind the ice maker was measured at 26 lux. Making visibility during cleaning difficult.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around deck-mounted equipment.
|
|
|
Item No.:
19
|
|
Site:
Buffet-Deck 6 - Open Buffet Line.
|
|
Violation:
Sliced bread was uncovered on top of the serving line. It was not fully protected under the sneeze guard.
|
|
Recommendation:
Protect food on display from contamination by the use of service line bar food guards.
|
|
|
Item No.:
29
|
|
Site:
Galley-Deck 2 - Handwash
|
|
Violation:
The water in the hand wash sink could not be adjusted below a temperature of126°F making handwashing difficult to perform correctly.
|
|
Recommendation:
Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet.
|
|
|
Item No.:
43
|
|
Site:
Ventilation-Deck 5 and Deck 6- Air Conditioning Units
|
|
Violation:
The air conditioning and condenser units utilizing with the white vertical baffles were very soiled with a black mold like residue. 7 units were inspected. The black substance was observed in AC 1-13 AP 108 and AC 3-14 AP158.
|
|
Recommendation:
Keep air handling units clean.
|
|
|
Item No.:
27
|
|
Site:
Galley-Deck 2 - Technical Area Port Side
|
|
Violation:
The area in a technical space behind a compressor was difficult to clean and contained insect or rodent feces. Direct examination was not possible by the IMP manager present because there was live electrical equipment in the space.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-IPM Records
|
|
Violation:
IPM records were not complete during active monitoring indicating actual observations. Records indicated application of pesticides but there was no amplifying information about the pests in the area or any documentation or follow-up after application with observations.
|
|
Recommendation:
Ensure the IPM Plan includes provisions for logs for active monitoring of pest sightings in operational areas of the vessel. Record the time and results of the active monitoring inspections in the log.
|
|
|
Item No.:
36
|
|
Site:
Galley-Deck 2 - Lighting behind Combination Oven
|
|
Violation:
Lighting behind the combination oven on the port side was measured at an intensity of 55lux making cleaning difficult.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck behind and around deck-mounted equipment.
|
|
|
Item No.:
22
|
|
Site:
Galley-Deck 2 - Warewasher
|
|
Violation:
Seven coffee cups were observed exiting the washer right side up containing dirty wash and rinse water. It was explained that the water jets turned these cups over while washing. Measures were taken to place an additional rack on top to prevent this. The cups were rewashed.
|
|
Recommendation:
Ensure soiled items to be cleaned in a warewashing machine are loaded into racks in a position that (1) exposes the items to the unobstructed spray from all cycles; (2) allows the items to drain.
|
|
|
Item No.:
37
|
|
Site:
Galley-Deck 2 - Warewasher
|
|
Violation:
Poor ventilation at the dirty side of the warewasher allowed a heavy condensate to drip back onto the dishwasher and also out into the clean aisle adjacent to the warewasher. Steam was observed flowing from the ventilation ducts out into this area.
|
|
Recommendation:
Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent condensation from collecting on bulkheads and deckheads.
|
|
|
Item No.:
27
|
|
Site:
Pantry-Deck 2 - Wine Bar
|
|
Violation:
The technical area under the counter at the serving area contained debris and dust. It was difficult to reach and clean.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
36
|
|
Site:
Pantry-Deck 2 - Wine Bar
|
|
Violation:
The intensity of the lighting in this area measured at 77 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at handwashing stations in bars. In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
|
|
|
Item No.:
20
|
|
Site:
Bar-Deck 5 Vine Bar Aft
|
|
Violation:
A new coffee machine was installed with 2 slotted fasteners within the food splash contact area.
|
|
Recommendation:
Ensure multiuse food-contact surfaces use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-AGE Plan
|
|
Violation:
The OPRP has been undergoing recent revisions. Items in the plan were updated to comply with the VSP Operations Manual identifying correct concentrations and contact times of disinfectants. However specific trigger points were not defined for 'step-down' procedures. There were also no written plans identifying how the passengers and crew would specifically be notified during outbreaks and during the stages. The current explanation is to defer to the doctor on board for the specific trigger points. There were no written procedures for informing embarking crew members or passengers following an outbreak.
|
|
Recommendation:
Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (1) Duties and responsibilities of each department and their staff for all the passenger and crew public areas; (2) Steps in outbreak management and control and the trigger for required action at each step. Ensure the triggers address a graduated approach to outbreak management in response to increasing case counts; (3) Procedures for informing passengers and crew members of the outbreak. Ensure this section also includes procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage; (4) Procedures for returning the vessel to normal operating conditions after an outbreak; (5) Procedures to protect the passengers and crew from exposure to disinfectants, if not already included in the vessel?s safety management system.
|
|
|
Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Surveillance Logs
|
|
Violation:
The AGE surveillance logs were not in the same order as outlined in the VSP Operations Manual annex 13.2.2. Specifically, the case ID was not the first column and there was no column for the time passengers/crew reported to the medical center.
|
|
Recommendation:
Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Date of the first medical visit or report to staff of illness; (2) time of the first medical visit or report to staff of illness; (3) case identification number; (4) person?s name; (5) person?s age; (6) person?s sex; (7) designation as passenger or crew member; (8) crew member position or job on the vessel, if applicable; (9) cabin number; (10) meal seating information; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24-hour period; (b) number of episodes of vomiting in a 24-hour period; (c) bloody stools; (d) recorded temperature; (e) abdominal cramps; (f) headaches; (g) muscle aches; (14) entry (yes/no) for whether this was a reportable case; (15) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (16) presence of underlying medical conditions that may affect interpretation of AGE. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP.
|
|
|
Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Surveillance Logs
|
|
Violation:
The total number of passengers and crew listed on the AGE log was different than the highest numbers onboard during the voyage. For example, for voyage 2714 (26 October to 11 November) the AGE log listed 362 passengers, however the highest passenger count onboard was 354; for voyage 2614 (10-26 October) the AGE log listed 343 passengers and 164 crew, however the highest count onboard was 349 passengers and 168 crew; for voyage 2514 (24 September to 10 October) the AGE log listed 372 passengers and 163 crew, however the highest count onboard was 371 passengers and 164 crew.
|
|
Recommendation:
Ensure the AGE report contains the total number of passengers and crew members on the cruise.
|
|
|
Item No.:
03
|
|
Site:
Potable Water-Production Records
|
|
Violation:
During the production of potable water on 21 November, the chlorine values were approximately 0.15 ppm from 13:30 - 16:00. At about 13:00 a note was written on the chart stating 'damaged chlorination pipe.' The engineer explained to the inspector that a hole had formed in the tube and chlorine was leaking from the tube. The chlorine levels continued to drop until the engineer returned from break, at which time he replaced the plastic tube and restarted the chlorination feed. The engineer on watch at the time did not stop production when the levels dropped.
|
|
Recommendation:
Continuously halogenate potable water to at least 2.0 mg/L (ppm) free residual halogen at the time of r production with an automatic halogenation device that is controlled by a flow meter and adjust the pH so it does not exceed 7.8. Ensure the amount of halogen injected during bunkering or production is controlled by a flow meter or a free halogen analyzer.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Bunkering and Production Records
|
|
Violation:
The calibration or calibration check was not consistently documented on the potable water bunkering and production charts. Occasionally, bunkering or production would start and stop throughout the day, with no calibration check before each start. This was written on the last inspection.
|
|
Recommendation:
Record the daily manual comparison test or calibration either on the recorder chart or in a log. Adjust the free halogen residual level to at least 2.0 mg/L (ppm) within 30 minutes of the start of the bunkering and production processes.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Far Point
|
|
Violation:
According to the chart on 17 November, the chlorine values at the far point were greater than 5.0 ppm from 15:30 - 22:30. There was a notation about the high potable water bunkering values that day. The bunkering record indicated the manual shoreside test and onboard tests throughout the day were 6.0 ppm chlorine.
|
|
Recommendation:
Provide continuous halogenation of the potable water system using halogenation injection equipment and maintain a free residual halogen between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) throughout the distribution system.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Far Point
|
|
Violation:
The same chart was used for the far point values on 18-19 November.
|
|
Recommendation:
Change, initial, and date halogen analyzer-chart recorder charts daily. Ensure the charts contain notations of any unusual events in the potable water system.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Testable Devices
|
|
Violation:
No records were available showing the pressure differences of the testable backflow prevention devices. The engineer stated all devices were tested in the beginning on November, but only the results from the AC Chiller Water was recorded.
|
|
Recommendation:
Inspect and test backflow prevention devices requiring testing with a test kit after installation and at least annually. Maintain the test results showing the pressure differences on both sides of the valves for each device.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Mineralizer Drain Line
|
|
Violation:
The mineralizer backwash drain line was not included on the list of air gaps. Upon inspection, the end of the drain line was plugged with a metal fixture. The engineer explained the mineralizer was used, but the drain line was not. A similar finding was written on the last inspection with a hose connected to this drain line.
|
|
Recommendation:
Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Maintain backflow prevention devices in good repair.
|
|
|
Item No.:
05
|
|
Site:
Potable Water-Far Point Analyzer
|
|
Violation:
The halogen analyzer was reading 2.66 - 2.71 ppm during the time that manual tests were 0.79, 0.68, 0.76, 0.79, and 0.89 ppm free chlorine residual by both the engineer and inspector. The analyzer was reading over 1.7 ppm out of calibration at the time of the inspection.
|
|
Recommendation:
Ensure the free residual halogen measured by the halogen analyzer is within 0.2 mg/L (ppm) of the free residual halogen measured by the manual test. Maintain the halogen analyzer-chart recorder properly and operate it in accordance with the manufacturer?s instructions. Conduct a manual comparison test daily to verify calibration. Calibrate whenever the manual test value is greater than 0.2 ppm higher or lower than the analyzer reading.
|
|
|
Item No.:
09
|
|
Site:
Recreational Water Facilities-Swimming Pool
|
|
Violation:
Manual tests measured 0.46, 0.32, 0.70, 0.42, and 0.40 ppm free chlorine residual by both the engineer and inspector. The swimming pool was open at the time of the inspection.
|
|
Recommendation:
Maintain a free residual halogen in recirculated swimming pools is between 1.0 and 5.0 mg/L (ppm). Immediately close facilities if halogen ranges are not maintained.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Swimming Pool
|
|
Violation:
The halogen analyzer was reading 1.1 ppm during the time that manual tests were 0.46, 0.32, 0.70, 0.42, and 0.40 ppm free chlorine residual by both the engineer and inspector. The analyzer was reading over 0.7 ppm out of calibration at the time of the inspection. On the day of the inspection, no calibration was done on the analyzer.
|
|
Recommendation:
Maintain and operate the halogen and pH analyzer-chart recorder in accordance with the manufacturer?s instructions. Conduct a manual comparison test before opening the RWF to verify calibration for free halogen residual and pH. Ensure the analyzer reading is within 0.2 ppm for free halogen and 0.2 for pH. For RWFs open longer than 24 hours, conduct a manual comparison test every 24 hours.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Secondary Standards
|
|
Violation:
The secondary standards expired in June 2013. A purchase request was placed on 7 November for new standards.
|
|
Recommendation:
Ensure a test kit is available for testing water quality parameters. Ensure all reagents are not past their expiration dates.
|
|