Item No.:
*
|
|
Site:
Housekeeping-
|
|
Violation:
No test strips were available for the Antibacterial All-Purpose Cleaner. During outbreak prevention Levels Green and Yellow, the solution was pre-made within the dispenser at a concentration of 886 ppm. During outbreak prevention Level Red, staff prepared the solution using 2 ounces of Cleaner to 1 gallon of water. This gave a concentration of 3,544 ppm.
|
|
Recommendation:
Provide test strips to ensure proper concentration of the cleaner.
|
|
|
Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Surveillance Log
|
|
Violation:
The total number of passengers and/or crew members listed on the AGE logs did not match the numbers indicated on the electronic medical reports submitted to VSP. For the 5 - 12 December voyage, the AGE log stated 151 passengers and 221 crew, but the electronic medical report stated 138 passengers and 220 crew; for the 1 - 5 December voyage, the AGE log stated 261 passengers, but the electronic medical report stated 259 passengers.
|
|
Recommendation:
Report the highest number of passengers and crew members that were onboard at any time during the cruise. Include those who signed on and signed off during the cruise, to include contractors, crew members joining/leaving during the cruise, and passengers who depart or join the cruise other than on turn-around day. In the event of an outbreak, the highest number of passengers and crew members onboard during the cruise make up the cohort who may have been exposed to the pathogen.
|
|
|
Item No.:
08
|
|
Site:
Galley-La Terrazza
|
|
Violation:
The water line between the utility sink and the combination oven did not have a backflow prevention device.
|
|
Recommendation:
Install a continuous pressure backflow prevention device on the combination oven water line before the utility sink.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Sand Filter Sedimentation Test Results
|
|
Violation:
The sand filter sedimentation test results were not recorded. The most recent tests were completed on 4 December for the pool and 5 December for the whirlpools.
|
|
Recommendation:
Examine granular filter media for channels, mounds, or holes. Inspect a core sample of the filter media for excessive organic material accumulation using a recommended sedimentation method. For whirlpool spas and spa pools, ensure inspections and sedimentation tests are done monthly. For all other RWFs, ensure inspections and sedimentation tests are conducted quarterly. Change granular filter media for whirlpool spas and spa pools based on the inspection and sedimentation test results or every 12 months, whichever is more frequent. For all other RWFs, change granular filter media based on the inspection and sedimentation results or per the manufacturer's recommendations, whichever is more frequent. Record the results of both the filter inspection and sedimentation test.
|
|
|
Item No.:
16
|
|
Site:
Galley-Hot Galley
|
|
Violation:
One pan of poached eggs and a bowl of hollandaise sauce were on time control on the counter next to the bain marie. No time control discard label was attached to these food items.
|
|
Recommendation:
According to the VSP Operations Manual clarifications page to section 7.3.5.3.6, "containers of potentially hazardous food under time control and placed on preparation counters must be labeled with the discard time, even if the outlet is open less than 4 hours."
|
|
|
Item No.:
16
|
|
Site:
Galley-Garde Manger
|
|
Violation:
A small container of lobster bisque was stored in the walk-in refrigerator with a product temperature of 44°F. According to the cooling log the food was properly cooled the previous morning. The food was discarded.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above or 5°C (41°F) or less.
|
|
|
Item No.:
19
|
|
Site:
Galley-Hot Galley
|
|
Violation:
A deckhead technical hatch above the in-use bain marie was open. No one in the galley was working in the hatch at the time of the inspection.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
20
|
|
Site:
Galley-Ice Crusher
|
|
Violation:
Inside the ice machine, the white plastic water collection tray had black insulation around the side and bottom of the tray. The insulation on the side of the tray by the ice chute was extremely wet.
|
|
Recommendation:
Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent.
|
|
|
Item No.:
21
|
|
Site:
Galley-Beverage Station
|
|
Violation:
The pasta maker was mounted less than 100 millimeters (4 inches) above the counter-top.
|
|
Recommendation:
Ensure table-mounted equipment that is not easily movable is elevated on legs that provide at least a 100 mm (4-inch) clearance between the table and the equipment.
|
|
|
Item No.:
21
|
|
Site:
Bar-
|
|
Violation:
The preparation counter had two holes that were left opened after a piece of equipment was removed.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
22
|
|
Site:
Galley-Warewash
|
|
Violation:
The far left nozzles on the upper final sanitizing rinse manifold were completely blocked.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
|
|
|
Item No.:
22
|
|
Site:
Galley-Potwash
|
|
Violation:
The potwash machine had been out of order since 30 November. Crew were cleaning and sanitizing pots and pans in the three-compartment sink, but the volume of soiled items was large. Soiled pots and pans were stored in several different locations in the potwash area. The pots and pans were stacked high enough on the soiled landing counter to partially block the view of the hot galley. According to staff the potwash machine had been breaking down frequently the last few years of operation. The machine was originally installed on the ship 20 years ago.
|
|
Recommendation:
Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing. Repair or replace the potwash machine.
|
|
|
Item No.:
24
|
|
Site:
Galley-Warewash
|
|
Violation:
The final sanitizing rinse temperature for the in-use rack-type dishwash machine measured above 200°F on the manifold supply pipe after the booster heater. A 200°F maximum registering thermolabel was placed on the manifold supply pipe after the booster heater and the label immediately changed color, indicating the maximum temperature had been reached. The final sanitizing rinse temperature gauge read above 220°F when the rinse was activated. An excessive amount of steam was observed from the sanitizing rinse drain line.
|
|
Recommendation:
In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
|
|
|
Item No.:
27
|
|
Site:
Bar-Shutter
|
|
Violation:
The rolling shutter on the crew bar counter had an accumulation of dust in several areas.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Galley-Beverage Station
|
|
Violation:
The technical compartment of reach-in refrigerator MGB-1 was soiled with debris.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
33
|
|
Site:
Galley-Warewash
|
|
Violation:
The lower bulkhead profile strip was loose in several locations on the bulkhead behind the rack-type dishwash machine, creating a large gap that was difficult to clean.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Galley-Wine Cellar
|
|
Violation:
The lower bulkhead profile strip was loose under the handwash sink, creating a large gap that was difficult to clean.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Galley-Hot Galley
|
|
Violation:
Several deck tiles were cracked and chipped in front of the soup kettles and tilting pans. Grouting around the deck drains in front of the soup kettles and tilting pans was also recessed and/or missing in several locations.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Galley-Potwash
|
|
Violation:
The air conditioning unit was not completely sealed to the bulkhead.
|
|
Recommendation:
Ensure light fixtures, vent covers, and similar equipment attached to the bulkheads or deckheads are easily cleanable.
|
|
|
Item No.:
33
|
|
Site:
Galley-Ice Machines
|
|
Violation:
The lower bulkhead profile strip was loose in several locations in this area, creating a large gap that was difficult to clean.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Galley-Garde Manger
|
|
Violation:
Water was leaking from the air conditioning supply vent by the ice cream freezer and pooling on the deck. This area was not in operation at the time of the inspection and no food or equipment were impacted.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Galley-Storeroom
|
|
Violation:
A significant amount of dust had accumulated around the two deckhead exhaust vents.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Galley-La Terrazza Warewashing
|
|
Violation:
The corridor leading to the warewash area was not coved at the bulkhead/deck juncture.
|
|
Recommendation:
Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
|
|
|
Item No.:
33
|
|
Site:
Galley-La Terrazza Warewashing
|
|
Violation:
The exit door in the corridor had a gap on the bottom right corner.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Galley-Pool Grill
|
|
Violation:
Several of the light fixtures above the pool grill counter and in the corridor leading to the pantry had an accumulation of dead, small flies.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
34
|
|
Site:
Galley-Warewash
|
|
Violation:
The drains for the two handwash sinks at the soiled drop-off station were slow draining. Water accumulated in the basin to the point where it came into contact with the inspector's hands during washing.
|
|
Recommendation:
Ensure the plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
36
|
|
Site:
Preparation Room-
|
|
Violation:
The light intensity was less than 220 lux at the handwash station.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
37
|
|
Site:
Galley-Warewash
|
|
Violation:
Condensation was accumulating on the bulkhead around the clean landing area of the rack-type dishwash machine.
|
|
Recommendation:
Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
|
|
|
Item No.:
37
|
|
Site:
Galley-Hot Galley
|
|
Violation:
A significant amount of steam was produced by the in-use bain marie that was on time control. The steam was condensing and accumulating on the deckhead air conditioning supply vent. No food or equipment were impacted.
|
|
Recommendation:
Ensure all food preparation, warewashing, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes. Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them.
|
|
|
Item No.:
38
|
|
Site:
Pantry-6
|
|
Violation:
The ice machine was posted out of service since October. A work order was shown stating the water pump was broken. Communication between the ship and the company's purchasing agent was on-going the day before the inspection.
|
|
Recommendation:
Repair, remove, or replace the ice machine.
|
|
|
Item No.:
44
|
|
Site:
Ventilation-
|
|
Violation:
It was unclear how the filters were cleaned. The crew member responsible for the air handling units first explained that the filters were cleaned in the engine room using technical water. The inspection team was shown the wash area in the engine room and was informed that potable water was used from the nearby tap. A test of this water revealed no chlorine residual. Another crew member showed where the valve was turned to make the water source potable, and stated the same water tap was used. About 20 minutes later, the inspector was informed the filters were not washed, only discarded.
|
|
Recommendation:
Ensure the supervisor or person in charge of HVAC operations on the vessel demonstrates to VSP-during inspections and on request - knowledge of HVAC operations, is able to demonstrate this knowledge by compliance with Section 11 of the VSP 2011 Operations Manual or by responding correctly to the inspector's questions as they relate to the specific operation, and properly trains employees to comply with Section 11 of the VSP 2011 Operations Manual as it relates to their assigned duties. Use only potable water for cleaning HVAC distribution systems.
|
|